Biofidelity Evaluation of the THOR and Hybrid III 50th Percentile Male Frontal Impact Anthropomorphic Test Devices.

Daniel Parent1, Matthew Craig1, Kevin Moorhouse1.   

Abstract

The objective of this study is to present a quantitative comparison of the biofidelity of the THOR and Hybrid III 50th percentile male ATDs. Quantitative biofidelity was assessed using NHTSA's Biofidelity Ranking System in a total of 21 test conditions, including impacts to the head, face, neck, upper thorax, lower oblique thorax, upper abdomen, lower abdomen, femur, knee, lower leg, and whole-body sled tests to evaluate upper body kinematics and thoracic response under frontal and frontal oblique restraint loading. Biofidelity Ranking System scores for THOR were better (lower) than Hybrid III in 5 of 7 body regions for internal biofidelity and 6 of 7 body regions for external biofidelity. Nomenclature is presented to categorize the quantitative results, which show overall good internal and external biofidelity of the THOR compared to the good (internal) and marginal (external) biofidelity of the Hybrid III. The results highlight the excellent internal and external biofidelity of the THOR thorax.

Entities:  

Mesh:

Year:  2017        PMID: 29394441     DOI: 10.4271/2017-22-0009

Source DB:  PubMed          Journal:  Stapp Car Crash J        ISSN: 1532-8546


  4 in total

1.  Surface Contact Features, Impact Obliquity, and Preimpact Rotational Motion in Concussive Helmet-to-Ground Impacts: Assessment via a New Impact Test Device.

Authors:  Richard Kent; Jason Forman; Ann Bailey; Joseph Cormier; Gwansik Park; Jeff Crandall; Kristy B Arbogast; Barry Myers
Journal:  Ann Biomed Eng       Date:  2020-09-22       Impact factor: 3.934

2.  Consensus Head Acceleration Measurement Practices (CHAMP): Laboratory Validation of Wearable Head Kinematic Devices.

Authors:  Lee Gabler; Declan Patton; Mark Begonia; Ray Daniel; Ahmad Rezaei; Colin Huber; Gunter Siegmund; Tyler Rooks; Lyndia Wu
Journal:  Ann Biomed Eng       Date:  2022-09-14       Impact factor: 4.219

3.  Repeatability and Biofidelity of a Physical Surrogate Neck Model Fit to a Hybrid III Head.

Authors:  Samantha MacGillivray; Gabriella Wynn; Megan Ogle; Julia Shore; Jason P Carey; Christopher R Dennison
Journal:  Ann Biomed Eng       Date:  2021-05-17       Impact factor: 3.934

4.  Upper Limb Design of an Anthropometric Crash Test Dummy for Low Impact Rates.

Authors:  Marek Jaśkiewicz; Damian Frej; Dariusz Tarnapowicz; Milos Poliak
Journal:  Polymers (Basel)       Date:  2020-11-10       Impact factor: 4.329

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.