Literature DB >> 36104642

Consensus Head Acceleration Measurement Practices (CHAMP): Laboratory Validation of Wearable Head Kinematic Devices.

Lee Gabler1, Declan Patton2, Mark Begonia3, Ray Daniel4, Ahmad Rezaei5, Colin Huber2,6, Gunter Siegmund7,8, Tyler Rooks4, Lyndia Wu9.   

Abstract

Wearable devices are increasingly used to measure real-world head impacts and study brain injury mechanisms. These devices must undergo validation testing to ensure they provide reliable and accurate information for head impact sensing, and controlled laboratory testing should be the first step of validation. Past validation studies have applied varying methodologies, and some devices have been deployed for on-field use without validation. This paper presents best practices recommendations for validating wearable head kinematic devices in the laboratory, with the goal of standardizing validation test methods and data reporting. Key considerations, recommended approaches, and specific considerations were developed for four main aspects of laboratory validation, including surrogate selection, test conditions, data collection, and data analysis. Recommendations were generated by a group with expertise in head kinematic sensing and laboratory validation methods and reviewed by a larger group to achieve consensus on best practices. We recommend that these best practices are followed by manufacturers, users, and reviewers to conduct and/or review laboratory validation of wearable devices, which is a minimum initial step prior to on-field validation and deployment. We anticipate that the best practices recommendations will lead to more rigorous validation of wearable head kinematic devices and higher accuracy in head impact data, which can subsequently advance brain injury research and management.
© 2022. The Author(s).

Entities:  

Keywords:  Accuracy; Best practices; Head impact kinematics; Recommendations; Validation

Year:  2022        PMID: 36104642     DOI: 10.1007/s10439-022-03066-0

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   4.219


  61 in total

1.  Validation of a helmet-based system to measure head impact biomechanics in ice hockey.

Authors:  Mari A Allison; Yun Seok Kang; John H Bolte; Matthew R Maltese; Kristy B Arbogast
Journal:  Med Sci Sports Exerc       Date:  2014-01       Impact factor: 5.411

2.  Measurement of Hybrid III Head Impact Kinematics Using an Accelerometer and Gyroscope System in Ice Hockey Helmets.

Authors:  Mari A Allison; Yun Seok Kang; Matthew R Maltese; John H Bolte; Kristy B Arbogast
Journal:  Ann Biomed Eng       Date:  2014-12-05       Impact factor: 3.934

3.  Comparison of NOCSAE head kinematics using the Hybrid III and EuroSID-2 necks.

Authors:  Mark T Begonia; Frank A Pintar; Narayan Yoganandan
Journal:  J Biomech       Date:  2018-08-23       Impact factor: 2.712

4.  Development and Evaluation of a Test Method for Assessing the Performance of American Football Helmets.

Authors:  Ann M Bailey; Erin J Sanchez; Gwansik Park; Lee F Gabler; James R Funk; Jeff R Crandall; Michael Wonnacott; Chris Withnall; Barry S Myers; Kristy B Arbogast
Journal:  Ann Biomed Eng       Date:  2020-10-06       Impact factor: 3.934

5.  Measuring head kinematics in football: correlation between the head impact telemetry system and Hybrid III headform.

Authors:  Jonathan G Beckwith; Richard M Greenwald; Jeffrey J Chu
Journal:  Ann Biomed Eng       Date:  2011-10-13       Impact factor: 3.934

6.  Consensus Head Acceleration Measurement Practices (CHAMP): Origins, Methods, Transparency and Disclosure.

Authors:  Kristy B Arbogast; Jaclyn B Caccese; Thomas A Buckley; Andrew S McIntosh; Kyvory Henderson; Brian D Stemper; Gary Solomon; Steven P Broglio; James R Funk; Jeff R Crandall
Journal:  Ann Biomed Eng       Date:  2022-08-03       Impact factor: 4.219

7.  ES-2 Dummy Biomechanical Responses.

Authors:  Katie Byrnes; Joseph Abramczyk; Jeff Berliner; Annette Irwin; Jack Jensen; Murthy Kowsika; Harold J Mertz; Stephen W Rouhana; Risa Scherer; Yibing Shi; Aleta Sutterfield; Lan Xu; Suzanne Tylko; Dainius Dalmotas
Journal:  Stapp Car Crash J       Date:  2002-11

8.  Validation of an "Intelligent Mouthguard" Single Event Head Impact Dosimeter.

Authors:  Adam Bartsch; Sergey Samorezov; Edward Benzel; Vincent Miele; Daniel Brett
Journal:  Stapp Car Crash J       Date:  2014-11

9.  Impact Performance Comparison of Advanced Bicycle Helmets with Dedicated Rotation-Damping Systems.

Authors:  Michael Bottlang; Alexandra Rouhier; Stanley Tsai; Jordan Gregoire; Steven M Madey
Journal:  Ann Biomed Eng       Date:  2019-07-24       Impact factor: 3.934

10.  Development of the STAR Evaluation System for Assessing Bicycle Helmet Protective Performance.

Authors:  Megan L Bland; Craig McNally; David S Zuby; Becky C Mueller; Steven Rowson
Journal:  Ann Biomed Eng       Date:  2019-08-01       Impact factor: 3.934

View more
  1 in total

1.  Consensus Head Acceleration Measurement Practices (CHAMP): Study Design and Statistical Analysis.

Authors:  Steve Rowson; Jason Mihalik; Jillian Urban; Julianne Schmidt; Steve Marshall; Jaroslaw Harezlak; Brian D Stemper; Mike McCrea; Jim Funk
Journal:  Ann Biomed Eng       Date:  2022-10-17       Impact factor: 4.219