In Sook Jeong1, Sung Hee Lee1, Seak Hee Oh1, Do Hyun Park2, Kyung Mo Kim3.
Abstract
AIM: To evaluate the use of fully covered self-expandable metal stents (FCSEMSs) for pancreatic duct strictures in children with chronic pancreatitis.Entities:
Keywords: Child; Chronic pancreatitis; Endoscopic retrograde cholangiopancreatography; Pancreatic duct; Self-expandable metal stent
Mesh:
Year: 2018 PMID: 29391763 PMCID: PMC5776402 DOI: 10.3748/wjg.v24.i3.408
Source DB: PubMed Journal: World J Gastroenterol ISSN: 1007-9327 Impact factor: 5.742
Baseline characteristics of the 8 patients with refractory benign dominant main pancreatic duct strictures treated with a fully covered self-expandable metal stent
| 1 | F | Pancreas divisum | 2 | 25.5 (19-32) | 17 | Head | 6/4 | |
| 2 | M | - | 7 | 42.0 (4-93) | 12 | Head | 6/5 | |
| 3 | M | Incomplete pancreas divisum | - | 4 | 126.5 (63-431) | 10 | Head | 6/6 |
| 4 | M | Pancreas divisum | 3 | 57.0 (1-109) | 12 | Body | 6/7 | |
| 5 | F | - | 1 | 46.0 | 18 | Neck | 6/7 | |
| 6 | M | - | 2 | 58 (24-92) | 5 | Head | 6/4 | |
| 7 | F | - | 1 | 87 | 9 | Head | 6/4 | |
| 8 | M | - | 1 | 29 | 16 | Neck | 6/7 |
Single and multiple stents were used in our study. FCSEMS: Fully covered self-expandable metal stent.
Figure 1The fully covered self-expandable metal stent with 3 flaps at both ends used in this study (Hanarostent Biliary dual flap; M.I. Tech, Seoul, South Korea). A and B: The border between the gray and yellow points, shown by the blue arrows, marks the end of the stent. C: Small red arrow heads indicate the flaps.
Resolution of pancreatic duct strictures after the first placement of a fully covered self-expandable metal stent
| 1 | 3 | 0.8 | 3.0 | 6.5 | 4.9 |
| 2 | 10 | 1.5 | 2.0 | 12.1 | 8.7 |
| 3 | 6 | 1.2 | 3.4 | 11.3 | 7.1 |
| 4 | 6 | 0.9 | 3.4 | 8.1 | 6.4 |
| 5 | 6 | 1.0 | 4.4 | 7.1 | 5.0 |
| 6 | 6 | 0.9 | 0.9 | 6.0 | 5.2 |
| 7 | 6 | 1.6 | 2.1 | 9.4 | 6.1 |
| 8 | 6 | 0.8 | 3.0 | 7.0 | 7.0 |
| mean ± SD | 6 | 1.1 ± 0.3 | 2.8 ± 0.9 | 8.4 ± 2.5 | 6.3 ± 1.6 |
| NA | 0.017 | 0.018 | |||
The diameter was measured at the dilated segment upstream of the pancreatic duct stricture;
Expressed as a median value. NA: Not applicable.
Figure 2Endoscopic retrograde pancreatography images for case 3. A: Pancreatography image showing a pancreatic duct stricture in the pancreatic neck before the insertion of the fully covered self-expandable metal stent (FCSEMS). B and C: An FCSEMS with flaps placed through the narrow pancreatic duct. D: The stent lumen showing patency at 6 mo after FCSEMS placement.
Feasibility and safety of the placement of a fully covered self-expandable metal stent based on the occurrence of adverse events
| 1 | N | Y | N | N | N | N | N |
| 2 | N | Y | N | N | N | N | N |
| 3 | N | Y | N | N | N | N | N |
| 4 | N | Y | N | N | N | N | N |
| 5 | N | Y | N | N | N | N | N |
| 6 | N | Y | N | N | N | N | N |
| 7 | N | Y | N | N | N | N | N |
| 8 | N | Y | N | N | N | N | N |
N: No; Y: Yes.