Improved detection of fMRI activation in the cerebellum at 7T with dielectric pads extending the imaging region of a commercial head coil.

Manushka V Vaidya1,2, Mariana Lazar1,2, Cem M Deniz1, Gillian G Haemer1,2, Gang Chen1,2, Mary Bruno1, Daniel K Sodickson1,2, Riccardo Lattanzi1,2, Christopher M Collins1,2.   

Abstract

BACKGROUND: There is growing interest in detecting cerebro-cerebellar circuits, which requires adequate blood oxygenation level dependent contrast and signal-to-noise ratio (SNR) throughout the brain. Although 7T scanners offer increased SNR, coverage of commercial head coils is currently limited to the cerebrum.
PURPOSE: To improve cerebellar functional MRI (fMRI) at 7T with high permittivity material (HPM) pads extending the sensitivity of a commercial coil. STUDY TYPE: Simulations were used to determine HPM pad configuration and assess radiofrequency (RF) safety. In vivo experiments were performed to evaluate RF field distributions and SNR and assess improvements of cerebellar fMRI.
SUBJECTS: Eight healthy volunteers enrolled in a prospective motor fMRI study with and without HPM. FIELD STRENGTH/SEQUENCE: Gradient echo (GRE) echo planar imaging for fMRI, turbo FLASH for flip angle mapping, GRE sequence for SNR maps, and T1 -weighted MPRAGE were acquired with and without HPM pads at 7T. ASSESSMENT: Field maps, SNR maps, and anatomical images were evaluated for coverage. Simulation results were used to assess SAR levels of the experiment. Activation data from fMRI experiments were compared with and without HPM pads. STATISTICAL TESTS: fMRI data were analyzed using FEAT FSL for each subject followed by group level analysis using paired t-test of acquisitions with and without HPM.
RESULTS: Simulations showed 52% improvement in transmit efficiency in cerebellum with HPM and SAR levels well below recommended limits. Experiments showed 27% improvement in SNR in cerebellum and improvement in coverage on T1 -weighted images. fMRI showed greater cerebellar activation in individual subjects with the HPM pad present (Z > = 4), especially in inferior slices of cerebellum, with 59% average increase in number of activated voxels in the cerebellum. Group-level analysis showed improved functional activation (Z > = 2.3) in cerebellar regions with HPM pads without loss of measured activation elsewhere. DATA
CONCLUSION: HPM pads can improve cerebellar fMRI at 7T with a commonly-used head coil without compromising RF safety. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2018;48:431-440.
© 2018 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  SAR; SNR; brain imaging; cerebellum; fMRI; high permittivity materials

Mesh:

Substances:

Year:  2018        PMID: 29357200      PMCID: PMC6054823          DOI: 10.1002/jmri.25936

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  35 in total

1.  Evidence for a motor somatotopy in the cerebellar dentate nucleus--an FMRI study in humans.

Authors:  Michael Küper; Markus Thürling; Roxana Stefanescu; Stefan Maderwald; Johannes Roths; Hans G Elles; Mark E Ladd; Jörn Diedrichsen; Dagmar Timmann
Journal:  Hum Brain Mapp       Date:  2011-09-21       Impact factor: 5.038

2.  Mapping of the radio frequency magnetic field with a MR snapshot FLASH technique.

Authors:  U Klose
Journal:  Med Phys       Date:  1992 Jul-Aug       Impact factor: 4.071

3.  Reduction of RF penetration effects in high field imaging.

Authors:  T K Foo; C E Hayes; Y W Kang
Journal:  Magn Reson Med       Date:  1992-02       Impact factor: 4.668

4.  Simulations of high permittivity materials for 7 T neuroimaging and evaluation of a new barium titanate-based dielectric.

Authors:  W M Teeuwisse; W M Brink; K N Haines; A G Webb
Journal:  Magn Reson Med       Date:  2012-01-27       Impact factor: 4.668

5.  Manipulation of image intensity distribution at 7.0 T: passive RF shimming and focusing with dielectric materials.

Authors:  Qing X Yang; Weihua Mao; Jinghua Wang; Michael B Smith; Hao Lei; Xiaoliang Zhang; Kamil Ugurbil; Wei Chen
Journal:  J Magn Reson Imaging       Date:  2006-07       Impact factor: 4.813

6.  Electromagnetic fields of surface coil in vivo NMR at high frequencies.

Authors:  J R Keltner; J W Carlson; M S Roos; S T Wong; T L Wong; T F Budinger
Journal:  Magn Reson Med       Date:  1991-12       Impact factor: 4.668

7.  New high dielectric constant materials for tailoring the B1+ distribution at high magnetic fields.

Authors:  K Haines; N B Smith; A G Webb
Journal:  J Magn Reson       Date:  2010-01-11       Impact factor: 2.229

8.  Quantitative assessment of the effects of high-permittivity pads in 7 Tesla MRI of the brain.

Authors:  Wouter M Teeuwisse; Wyger M Brink; Andrew G Webb
Journal:  Magn Reson Med       Date:  2011-08-08       Impact factor: 4.668

Review 9.  Functional magnetic resonance imaging (FMRI) of the human brain.

Authors:  E A DeYoe; P Bandettini; J Neitz; D Miller; P Winans
Journal:  J Neurosci Methods       Date:  1994-10       Impact factor: 2.390

10.  Permittivity and performance of dielectric pads with sintered ceramic beads in MRI: early experiments and simulations at 3 T.

Authors:  Wei Luo; Michael T Lanagan; Christopher T Sica; Yeunchul Ryu; Sukhoon Oh; Matthew Ketterman; Qing X Yang; Christopher M Collins
Journal:  Magn Reson Med       Date:  2012-08-13       Impact factor: 4.668

View more
  7 in total

1.  A nine-channel transmit/receive array for spine imaging at 10.5 T: Introduction to a nonuniform dielectric substrate antenna.

Authors:  Alireza Sadeghi-Tarakameh; Steve Jungst; Mike Lanagan; Lance DelaBarre; Xiaoping Wu; Gregor Adriany; Gregory J Metzger; Pierre-Francois Van de Moortele; Kamil Ugurbil; Ergin Atalar; Yigitcan Eryaman
Journal:  Magn Reson Med       Date:  2021-11-26       Impact factor: 4.668

Review 2.  Neuroimaging at 7 Tesla: a pictorial narrative review.

Authors:  Tomohisa Okada; Koji Fujimoto; Yasutaka Fushimi; Thai Akasaka; Dinh H D Thuy; Atsushi Shima; Nobukatsu Sawamoto; Naoya Oishi; Zhilin Zhang; Takeshi Funaki; Yuji Nakamoto; Toshiya Murai; Susumu Miyamoto; Ryosuke Takahashi; Tadashi Isa
Journal:  Quant Imaging Med Surg       Date:  2022-06

3.  High-permittivity pad design tool for 7T neuroimaging and 3T body imaging.

Authors:  Jeroen van Gemert; Wyger Brink; Andrew Webb; Rob Remis
Journal:  Magn Reson Med       Date:  2018-12-18       Impact factor: 4.668

4.  Whole brain 7T-fMRI during pelvic floor muscle contraction in male subjects.

Authors:  Ilse M Groenendijk; Sven P R Luijten; Chris I de Zeeuw; Joan C Holstege; Jeroen R Scheepe; Wietske van der Zwaag; Bertil F M Blok
Journal:  Neurourol Urodyn       Date:  2019-11-13       Impact factor: 2.696

5.  Single subject and group whole-brain fMRI mapping of male genital sensation at 7 Tesla.

Authors:  Sven P R Luijten; Ilse M Groenendijk; Joan C Holstege; Chris I De Zeeuw; Wietske van der Zwaag; Bertil F M Blok
Journal:  Sci Rep       Date:  2020-02-12       Impact factor: 4.379

6.  A local multi-transmit coil combined with a high-density receive array for cerebellar fMRI at 7 T.

Authors:  Nikos Priovoulos; Thomas Roos; Özlem Ipek; Ettore F Meliado; Richard O Nkrumah; Dennis W J Klomp; Wietske van der Zwaag
Journal:  NMR Biomed       Date:  2021-07-06       Impact factor: 4.044

7.  A Comparative Study of Birdcage RF Coil Configurations for Ultra-High Field Magnetic Resonance Imaging.

Authors:  Jeung-Hoon Seo; Yeji Han; Jun-Young Chung
Journal:  Sensors (Basel)       Date:  2022-02-23       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.