Literature DB >> 1549043

Reduction of RF penetration effects in high field imaging.

T K Foo1, C E Hayes, Y W Kang.   

Abstract

A method of correcting for the RF inhomogeneity in the body by dielectric loading of the coil-to-shield space in an RF resonator (coil and shield assembly) is described. The presence of the RF coil and RF shield have significant effects on RF homogeneity. Based on theoretical calculations, a method for adjusting the RF homogeneity by manipulating the axial propagation constant, kappa z, is proposed. This is accomplished by loading the coil-to-shield space with dielectric material of suitable relative permittivity so as to increase kappa z and decrease the radial propagation constant, kappa rho. In this manner, the radial wavelength (lambda rho = 2 pi/kappa rho) can be increased relative to the body dimensions, and the field amplitude variations in the axial plane minimized. Theoretical calculations indicate that a value of between 30 and 40 for the relative permittivity of the dielectric material in the coil-to-shield space would reduce the RF field inhomogeneity from +/- 15% to about +/- 3% over a central 30-cm-diameter region of a homogeneous 40-cm-diameter body at both 64 and 170 MHz. The theoretical model was verified in laboratory measurements of the [formula; see text] field generated in a test coil at 170 MHz which was scaled to correspond to a body at 64 MHz. However, the improved RF field homogeneity would be accompanied by increased RF power requirements and reduced coil sensitivity.

Mesh:

Year:  1992        PMID: 1549043     DOI: 10.1002/mrm.1910230209

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  Partial volume segmentation of brain magnetic resonance images based on maximum a posteriori probability.

Authors:  Xiang Li; Lihong Li; Hongbing Lu; Zhengrong Liang
Journal:  Med Phys       Date:  2005-07       Impact factor: 4.071

2.  A method of RF inhomogeneity correction in MR imaging.

Authors:  H Mihara; N Iriguchi; S Ueno
Journal:  MAGMA       Date:  1998-12       Impact factor: 2.310

3.  A novel method to decrease electric field and SAR using an external high dielectric sleeve at 3 T head MRI: numerical and experimental results.

Authors:  Bu S Park; Sunder S Rajan; Joshua W Guag; Leonardo M Angelone
Journal:  IEEE Trans Biomed Eng       Date:  2014-10-22       Impact factor: 4.538

4.  Interactive segmentation of plexiform neurofibroma tissue: method and preliminary performance evaluation.

Authors:  Lior Weizman; Lior Hoch; Dafna Ben Bashat; Leo Joskowicz; Li-tal Pratt; Shlomi Constantini; Liat Ben Sira
Journal:  Med Biol Eng Comput       Date:  2012-06-16       Impact factor: 2.602

5.  Reducing SAR and enhancing cerebral signal-to-noise ratio with high permittivity padding at 3 T.

Authors:  Qing X Yang; Jianli Wang; Jinghua Wang; Christopher M Collins; Chunsheng Wang; Michael B Smith
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

6.  Improved detection of fMRI activation in the cerebellum at 7T with dielectric pads extending the imaging region of a commercial head coil.

Authors:  Manushka V Vaidya; Mariana Lazar; Cem M Deniz; Gillian G Haemer; Gang Chen; Mary Bruno; Daniel K Sodickson; Riccardo Lattanzi; Christopher M Collins
Journal:  J Magn Reson Imaging       Date:  2018-01-21       Impact factor: 4.813

7.  The evaluation of dielectric resonators containing H2O or D2O as RF coils for high-field MR imaging and spectroscopy.

Authors:  H Wen; F A Jaffer; T J Denison; S Duewell; A S Chesnick; R S Balaban
Journal:  J Magn Reson B       Date:  1996-02

8.  Manipulating transmit and receive sensitivities of radiofrequency surface coils using shielded and unshielded high-permittivity materials.

Authors:  Manushka V Vaidya; Cem M Deniz; Christopher M Collins; Daniel K Sodickson; Riccardo Lattanzi
Journal:  MAGMA       Date:  2017-11-06       Impact factor: 2.310

9.  Practical methods for improving B1+ homogeneity in 3 Tesla breast imaging.

Authors:  Simone A Winkler; Brian K Rutt
Journal:  J Magn Reson Imaging       Date:  2014-04-10       Impact factor: 4.813

10.  Improvement of Electromagnetic Field Distributions Using High Dielectric Constant (HDC) Materials for CTL-Spine MRI: Numerical Simulations and Experiments.

Authors:  Bu S Park; Brent McCright; Leonardo M Angelone; Amir Razjouyan; Sunder S Rajan
Journal:  IEEE Trans Electromagn Compat       Date:  2017-10       Impact factor: 2.006

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.