Literature DB >> 19463664

Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: an in vitro study.

Chanseop Park1, Ariel J Raigrodski, Jacob Rosen, Charles Spiekerman, Robert M London.   

Abstract

STATEMENT OF PROBLEM: Surgical guides may interfere with effective use of surgical instrumentation during implant placement in the posterior segments where interocclusal distance may be limited.
PURPOSE: The purpose of this study was to measure and compare the accuracy of posterior implant placement using 3 precision surgical guides with varying occlusogingival heights, and to evaluate the difference in accuracy of implant placement through precision guides as compared to freehand placement.
MATERIAL AND METHODS: Three groups of surgical guides were fabricated with occlusogingival heights of 4, 6, and 8 mm, respectively. A jig was fabricated to allow for accurate positioning in bone substitute blocks. Ninety implants were placed in the mandibular first molar site on a manikin. Thirty implants (Astra Tech AB) were placed for each group, with 15 through the guide and 15 freehand. Distances between a reference implant and each placed implant were measured at both implant and abutment levels using a coordinate measuring machine. Apex position and angular discrepancy were calculated using the coordinates of the centers of the implant platform and of the occlusal aspect of the abutment. Data was assessed using 2-way ANOVA (alpha=.05).
RESULTS: Two-way ANOVA demonstrated that guide height did not significantly affect the accuracy of the implant position. The distance from the reference point to the point of measurement was significantly smaller for placement through the guide compared to freehand placement at both implant (P<.001) and abutment levels (P<.001). The angular discrepancy was also significantly smaller for placement through the guide (P<.001).
CONCLUSIONS: Precision surgical guides with 4-mm occlusogingival height allow placement as accurate as precision guides with 8-mm height. Placement through the guide reproduced the target position more accurately than freehand insertion.

Mesh:

Year:  2009        PMID: 19463664     DOI: 10.1016/S0022-3913(09)60080-9

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  11 in total

1.  Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement.

Authors:  Wei Geng; Changying Liu; Yucheng Su; Jun Li; Yanmin Zhou
Journal:  Int J Clin Exp Med       Date:  2015-06-15

2.  Designing a custom made gauge device for application in the access hole correction in the dental implant surgical guide.

Authors:  Elnaz Moslehifard; Saeid Nokar
Journal:  J Indian Prosthodont Soc       Date:  2011-10-16

3.  3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study.

Authors:  Sigmar Schnutenhaus; Cornelia Edelmann; Heike Rudolph; Jens Dreyhaupt; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2018-01-22       Impact factor: 3.573

4.  Accuracy of orthodontic miniscrew implantation guided by stereolithographic surgical stent based on cone-beam CT-derived 3D images.

Authors:  Lingling Qiu; Naoto Haruyama; Shoichi Suzuki; Daisuke Yamada; Naoto Obayashi; Toru Kurabayashi; Keiji Moriyama
Journal:  Angle Orthod       Date:  2011-08-17       Impact factor: 2.079

5.  An organized start to implant-supported prosthesis.

Authors:  Suma Karthigeyan; Seyed Ashraff Ali; Kalarani Mohan; Mangala Deivanai
Journal:  Contemp Clin Dent       Date:  2013-01

6.  An assessment of template-guided implant surgery in terms of accuracy and related factors.

Authors:  Jee-Ho Lee; Ji-Man Park; Soung-Min Kim; Myung-Joo Kim; Jong-Ho Lee; Myung-Jin Kim
Journal:  J Adv Prosthodont       Date:  2013-11-28       Impact factor: 1.904

7.  Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study.

Authors:  Du-Hyeong Lee; Seo-Young An; Min-Ho Hong; Kyoung-Bae Jeon; Kyu-Bok Lee
Journal:  J Adv Prosthodont       Date:  2016-06-17       Impact factor: 1.904

8.  Drill Bit Guiding System for Implant Placement.

Authors:  Loganathan Deepanandan; Giridhar Karthikrajan
Journal:  Ann Maxillofac Surg       Date:  2018 Jul-Dec

9.  Registration of cone beam computed tomography data and intraoral surface scans - A prerequisite for guided implant surgery with CAD/CAM drilling guides.

Authors:  Tabea Flügge; Wiebe Derksen; Jobine Te Poel; Bassam Hassan; Katja Nelson; Daniel Wismeijer
Journal:  Clin Oral Implants Res       Date:  2016-07-20       Impact factor: 5.977

10.  The accuracy of a 3D printing surgical guide determined by CBCT and model analysis.

Authors:  Boyoung Ma; Taeseok Park; Inkon Chun; Kwidug Yun
Journal:  J Adv Prosthodont       Date:  2018-08-17       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.