Literature DB >> 29311005

Preliminary Clinical Experience with a Combined Automated Breast Ultrasound and Digital Breast Tomosynthesis System.

Eric D Larson1, Won-Mean Lee2, Marilyn A Roubidoux2, Mitchell M Goodsitt2, Chris Lashbrook2, Cynthia E Davis3, Oliver D Kripfgans2, Paul L Carson2.   

Abstract

We analyzed the performance of a mammographically configured, automated breast ultrasound (McABUS) scanner combined with a digital breast tomosynthesis (DBT) system. The GE Invenia ultrasound system was modified for integration with GE DBT systems. Ultrasound and DBT imaging were performed in the same mammographic compression. Our small preliminary study included 13 cases, six of whom had contained invasive cancers. From analysis of these cases, current limitations and corresponding potential improvements of the system were determined. A registration analysis was performed to compare the ease of McABUS to DBT registration for this system with that of two systems designed previously. It was observed that in comparison to data from an earlier study, the McABUS-to-DBT registration alignment errors for both this system and a previously built combined system were smaller than those for a previously built standalone McABUS system.
Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  3-D imaging; Automated breast ultrasound; Combined system; Compression; Digital breast tomosynthesis; Mammography

Mesh:

Year:  2018        PMID: 29311005      PMCID: PMC5801205          DOI: 10.1016/j.ultrasmedbio.2017.12.003

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  16 in total

1.  A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis.

Authors:  Yiheng Zhang; Heang-Ping Chan; Berkman Sahiner; Jun Wei; Mitchell M Goodsitt; Lubomir M Hadjiiski; Jun Ge; Chuan Zhou
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

2.  Adding 3D automated breast ultrasound to mammography screening in women with heterogeneously and extremely dense breasts: Report from a hospital-based, high-volume, single-center breast cancer screening program.

Authors:  Brigitte Wilczek; Henryk E Wilczek; Lawrence Rasouliyan; Karin Leifland
Journal:  Eur J Radiol       Date:  2016-06-07       Impact factor: 3.528

3.  The connecticut experiments second year: ultrasound in the screening of women with dense breasts.

Authors:  Jean Weigert; Sarah Steenbergen
Journal:  Breast J       Date:  2015-02-16       Impact factor: 2.431

4.  Effect of a gel retainment dam on automated ultrasound coverage in a dual-modality breast imaging system.

Authors:  Jie Li; Mitchell M Goodsitt; Frederic Padilla; J Brian Fowlkes; Fong Ming Hooi; Christine R Lashbrook; Kai E Thomenius; Paul L Carson
Journal:  J Ultrasound Med       Date:  2010-07       Impact factor: 2.153

5.  Adjunct Screening With Tomosynthesis or Ultrasound in Women With Mammography-Negative Dense Breasts: Interim Report of a Prospective Comparative Trial.

Authors:  Alberto S Tagliafico; Massimo Calabrese; Giovanna Mariscotti; Manuela Durando; Simona Tosto; Francesco Monetti; Sonia Airaldi; Bianca Bignotti; Jacopo Nori; Antonella Bagni; Alessio Signori; Maria Pia Sormani; Nehmat Houssami
Journal:  J Clin Oncol       Date:  2016-03-09       Impact factor: 44.544

6.  Testing a dual-modality system that combines full-field digital mammography and automated breast ultrasound.

Authors:  Christopher L Vaughan; Tania S Douglas; Qonita Said-Hartley; Roland V Baasch; James A Boonzaier; Brian C Goemans; John Harverson; Michael W Mingay; Shuaib Omar; Raphael V Smith; Nielen C Venter; Heidi S Wilson
Journal:  Clin Imaging       Date:  2015-12-03       Impact factor: 1.605

7.  Digital breast tomosynthesis: studies of the effects of acquisition geometry on contrast-to-noise ratio and observer preference of low-contrast objects in breast phantom images.

Authors:  Mitchell M Goodsitt; Heang-Ping Chan; Andrea Schmitz; Scott Zelakiewicz; Santosh Telang; Lubomir Hadjiiski; Kuanwong Watcharotone; Mark A Helvie; Chintana Paramagul; Colleen Neal; Emmanuel Christodoulou; Sandra C Larson; Paul L Carson
Journal:  Phys Med Biol       Date:  2014-09-11       Impact factor: 3.609

8.  Automated Breast Ultrasound: Dual-Sided Compared with Single-Sided Imaging.

Authors:  Eric D Larson; Won-Mean Lee; Marilyn A Roubidoux; Mitchel M Goodsitt; Chris Lashbrook; Fouzaan Zafar; Oliver D Kripfgans; Kai Thomenius; Paul L Carson
Journal:  Ultrasound Med Biol       Date:  2016-06-03       Impact factor: 2.998

9.  Breast mass characterization using 3-dimensional automated ultrasound as an adjunct to digital breast tomosynthesis: a pilot study.

Authors:  Frederic Padilla; Marilyn A Roubidoux; Chintana Paramagul; Sumedha P Sinha; Mitchell M Goodsitt; Gerald L Le Carpentier; Heang-Ping Chan; Lubomir M Hadjiiski; J Brian Fowlkes; Annette D Joe; Katherine A Klein; Alexis V Nees; Mitra Noroozian; Stephanie K Patterson; Renee W Pinsky; Fong Ming Hooi; Paul L Carson
Journal:  J Ultrasound Med       Date:  2013-01       Impact factor: 2.153

10.  Automated Breast Ultrasound in Breast Cancer Screening of Women With Dense Breasts: Reader Study of Mammography-Negative and Mammography-Positive Cancers.

Authors:  Maryellen L Giger; Marc F Inciardi; Alexandra Edwards; John Papaioannou; Karen Drukker; Yulei Jiang; Rachel Brem; Jeremy Bancroft Brown
Journal:  AJR Am J Roentgenol       Date:  2016-04-04       Impact factor: 3.959

View more
  3 in total

Review 1.  Novel imaging approaches to screen for breast cancer: Recent advances and future prospects.

Authors:  Christopher L Vaughan
Journal:  Med Eng Phys       Date:  2019-10       Impact factor: 2.242

2.  PEGylation of Metal Oxide Nanoparticles Modulates Neutrophil Extracellular Trap Formation.

Authors:  Hunter T Snoderly; Kasey A Freshwater; Celia Martinez de la Torre; Dhruvi M Panchal; Jenna N Vito; Margaret F Bennewitz
Journal:  Biosensors (Basel)       Date:  2022-02-16

3.  First proof-of-concept evaluation of the FUSION-X-US-II prototype for the performance of automated breast ultrasound in healthy volunteers.

Authors:  Benedikt Schaefgen; Marija Juskic; Madeleine Hertel; Richard G Barr; Marcus Radicke; Anne Stieber; André Hennigs; Fabian Riedel; Christof Sohn; Joerg Heil; Michael Golatta
Journal:  Arch Gynecol Obstet       Date:  2021-05-10       Impact factor: 2.344

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.