Literature DB >> 27501888

Adding 3D automated breast ultrasound to mammography screening in women with heterogeneously and extremely dense breasts: Report from a hospital-based, high-volume, single-center breast cancer screening program.

Brigitte Wilczek1, Henryk E Wilczek2, Lawrence Rasouliyan3, Karin Leifland4.   

Abstract

PURPOSE: The aim of this study was to evaluate the impact of the 3D automated breast ultrasound (3D ABUS) when added to full field digital screening mammography (FFDSM), on breast cancer detection and recall rates in asymptomatic women with dense breasts examined in a high-volume breast cancer screening mammography center. METHODS AND MATERIAL: 1668 asymptomatic women, age 40-74 years, with heterogeneously dense parenchyma (ACR3) or extremely dense breast (ACR4) were included in the study. FFDSM was performed using standard craniocaudal (CC) and mediolateral oblique (MLO) views followed by anteroposterior (AP); lateral (LAT) and medial (MED) acquisitions of 3D ABUS in both breasts. All mammograms were double read by two dedicated breast radiologists. The 3D ABUS was read by the first radiologist immediately after reading the mammograms. The second reader looked at the 3D ABUS only if there was a need for consensus discussion because of unclear or abnormal mammograms or 3D ABUS.
RESULTS: The combined FFDSM and 3D ABUS generated a total of 6.6 cancers per 1000 women screened (95% CI: 3.0, 10.2; p<0.001) compared with 4.2 cancers per 1000 women screened (95% CI) for FFDSM alone. The difference in yield was an additional 2.4 detected cancers per 1000 women screened (95% CI: 0.6, 4.8; p<0.001). The corresponding recall rate per 1000 women screened was 13.8 (95% CI: 9.0, 19.8) for FFDSM alone and 22.8 for combined FFDSM and ABUS (95% CI: 16.2, 30.0), yielding a difference of an additional 9.0 recalls per 1000 women screened (95% CI: 3.0, 15.0; p=0.004).
CONCLUSION: The addition of 3D ABUS to FFDSM in women with ACR3 or ACR4 breast density significantly improved invasive breast cancer detection rate with an acceptable recall increase.
Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

Entities:  

Keywords:  3D ABUS; Breast cancer detection; Breast cancer screening; Breast density; FFDSM; Recall rate

Mesh:

Year:  2016        PMID: 27501888     DOI: 10.1016/j.ejrad.2016.06.004

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  40 in total

1.  Preliminary Clinical Experience with a Combined Automated Breast Ultrasound and Digital Breast Tomosynthesis System.

Authors:  Eric D Larson; Won-Mean Lee; Marilyn A Roubidoux; Mitchell M Goodsitt; Chris Lashbrook; Cynthia E Davis; Oliver D Kripfgans; Paul L Carson
Journal:  Ultrasound Med Biol       Date:  2018-01-05       Impact factor: 2.998

Review 2.  Novel imaging approaches to screen for breast cancer: Recent advances and future prospects.

Authors:  Christopher L Vaughan
Journal:  Med Eng Phys       Date:  2019-10       Impact factor: 2.242

3.  The performance of 3D ABUS versus HHUS in the visualisation and BI-RADS characterisation of breast lesions in a large cohort of 1,886 women.

Authors:  Athina Vourtsis; Aspasia Kachulis
Journal:  Eur Radiol       Date:  2017-08-21       Impact factor: 5.315

Review 4.  Automated breast ultrasound: basic principles and emerging clinical applications.

Authors:  Martina Zanotel; Iliana Bednarova; Viviana Londero; Anna Linda; Michele Lorenzon; Rossano Girometti; Chiara Zuiani
Journal:  Radiol Med       Date:  2017-08-28       Impact factor: 3.469

5.  Initial results of the FUSION-X-US prototype combining 3D automated breast ultrasound and digital breast tomosynthesis.

Authors:  Benedikt Schaefgen; Joerg Heil; Richard G Barr; Marcus Radicke; Aba Harcos; Christina Gomez; Anne Stieber; André Hennigs; Alexandra von Au; Julia Spratte; Geraldine Rauch; Joachim Rom; Florian Schütz; Christof Sohn; Michael Golatta
Journal:  Eur Radiol       Date:  2018-01-04       Impact factor: 5.315

6.  Comparison between automated breast volume scanner (ABVS) versus hand-held ultrasound as a second look procedure after magnetic resonance imaging.

Authors:  Rossano Girometti; Martina Zanotel; Viviana Londero; Massimo Bazzocchi; Chiara Zuiani
Journal:  Eur Radiol       Date:  2017-01-24       Impact factor: 5.315

7.  The value of coronal view as a stand-alone assessment in women undergoing automated breast ultrasound.

Authors:  Simone Schiaffino; Licia Gristina; Simona Tosto; Elena Massone; Sara De Giorgis; Alessandro Garlaschi; Alberto Tagliafico; Massimo Calabrese
Journal:  Radiol Med       Date:  2020-07-16       Impact factor: 3.469

Review 8.  Breast density implications and supplemental screening.

Authors:  Athina Vourtsis; Wendie A Berg
Journal:  Eur Radiol       Date:  2018-09-25       Impact factor: 5.315

9.  Automated breast volume scanner (ABVS) in assessing breast cancer size: A comparison with conventional ultrasound and magnetic resonance imaging.

Authors:  Rossano Girometti; Martina Zanotel; Viviana Londero; Anna Linda; Michele Lorenzon; Chiara Zuiani
Journal:  Eur Radiol       Date:  2017-10-10       Impact factor: 5.315

10.  3D Automated Breast Ultrasound System: Comparison of Interpretation Time of Senior Versus Junior Radiologist.

Authors:  Aydan Arslan; Gökhan Ertaş; Erkin Arıbal
Journal:  Eur J Breast Health       Date:  2019-07-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.