Literature DB >> 29296414

Feasibility, detectability and clinical experience with platinum fiducial seeds for MRI/CT fusion and real-time tumor tracking during CyberKnife® stereotactic ablative radiotherapy.

Vimoj J Nair1,2,3, Janos Szanto4,2,3, Eric Vandervoort4,2,3, Elizabeth Henderson4,2,5,3, Leonard Avruch6,2, Shawn Malone1,2,3, Pantarotto Jason R1,2,3.   

Abstract

BACKGROUND AND
PURPOSE: The purpose of this study is to review our experience with platinum fiducials in terms of feasibility of placement and detectability by both MRI and orthogonal x-ray images used in robotic SABR.Materials and
Methods: 29 consecutive SABR patients (30 tumors) treated using fiducial tracking between January 2011 and February 2012 were reviewed. A total of 108 fiducials implanted in or around various tumor sites were identified. The pixel value contrast (PVC) of fiducials seen on MRI mages and treatment unit x-ray images of patients and phantoms were analysed.
RESULTS: Migration rates were similar for PS versus GS and GC (6.2%). No difference was noted between the mean PVC in cirrhotic versus non-cirrhotic liver (60.4 vs. 47.9; p = 0.074). MRI sequences for tumors in the liver and other organs revealed a mean PVC for platinum superior to that of gold (p<0.001). No PVC difference was seen between gold and platinum on analysis of the treatment unit x-rays.
CONCLUSION: Platinum seeds provide a superior detectability in comparison to gold seeds or coils on MRI images and are detected equally well by an image guidance system using orthogonal x-rays, making them a better choice for fiducial-based CT-MRI registration.

Entities:  

Keywords:  CyberKnife; platinum fiducial; real-time tumor tracking; stereotactic radiotherapy

Year:  2015        PMID: 29296414      PMCID: PMC5675499     

Source DB:  PubMed          Journal:  J Radiosurg SBRT


  9 in total

1.  FTRAC--a robust fluoroscope tracking fiducial.

Authors:  Ameet Kumar Jain; Tabish Mustafa; Yu Zhou; Clif Burdette; Gregory S Chirikjian; Gabor Fichtinger
Journal:  Med Phys       Date:  2005-10       Impact factor: 4.071

2.  Geometric accuracy of a novel gimbals based radiation therapy tumor tracking system.

Authors:  Tom Depuydt; Dirk Verellen; Olivier Haas; Thierry Gevaert; Nadine Linthout; Michael Duchateau; Koen Tournel; Truus Reynders; Katrien Leysen; Mischa Hoogeman; Guy Storme; Mark De Ridder
Journal:  Radiother Oncol       Date:  2011-03       Impact factor: 6.280

3.  EUS-guided fiducial placement for stereotactic body radiotherapy in locally advanced and recurrent pancreatic cancer.

Authors:  Michael K Sanders; Arthur J Moser; Asif Khalid; Kenneth E Fasanella; Herbert J Zeh; Steven Burton; Kevin McGrath
Journal:  Gastrointest Endosc       Date:  2010-04-01       Impact factor: 9.427

4.  Contrast discrimination in human infants.

Authors:  B R Stephens; M S Banks
Journal:  J Exp Psychol Hum Percept Perform       Date:  1987-11       Impact factor: 3.332

5.  Discrimination of position and contrast in amblyopic and peripheral vision.

Authors:  D M Levi; S A Klein; H Wang
Journal:  Vision Res       Date:  1994-12       Impact factor: 1.886

6.  Coil spring fiducial markers placed safely using navigation bronchoscopy in inoperable patients allows accurate delivery of CyberKnife stereotactic radiosurgery.

Authors:  Carsten Schroeder; Rana Hejal; Philip A Linden
Journal:  J Thorac Cardiovasc Surg       Date:  2010-09-20       Impact factor: 5.209

7.  Histopathologic consideration of fiducial gold markers inserted for real-time tumor-tracking radiotherapy against lung cancer.

Authors:  Mikado Imura; Koichi Yamazaki; Kanako C Kubota; Tomoo Itoh; Rikiya Onimaru; Yasushi Cho; Yasuhiro Hida; Kichizo Kaga; Yuya Onodera; Shigeaki Ogura; Hirotoshi Dosaka-Akita; Hiroki Shirato; Masaharu Nishimura
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-09-19       Impact factor: 7.038

8.  Cardiac embolization of an implanted fiducial marker for hepatic stereotactic body radiotherapy: a case report.

Authors:  Hooman Hennessey; David Valenti; Tatiana Cabrera; Valerie Panet-Raymond; David Roberge
Journal:  J Med Case Rep       Date:  2009-11-20

9.  Safety and efficacy of ultrasound-guided fiducial marker implantation for CyberKnife radiation therapy.

Authors:  Jae Hyun Kim; Seong Sook Hong; Jung Hoon Kim; Hyun Jeong Park; Yun-Woo Chang; A Ram Chang; Seok-Beom Kwon
Journal:  Korean J Radiol       Date:  2012-04-17       Impact factor: 3.500

  9 in total
  4 in total

1.  Reducing errors in prostate tracking with an improved fiducial implantation protocol for CyberKnife based stereotactic body radiotherapy (SBRT).

Authors:  Oliver E Holmes; Julie Gratton; Janos Szanto; Eric Vandervoort; Janice Doody; Elizabeth Henderson; Scott C Morgan; Joseph O'Sullivan; Shawn Malone
Journal:  J Radiosurg SBRT       Date:  2018

2.  Endoscopic Ultrasound-Guided Fiducial Placement for Stereotactic Body Radiation Therapy in Pancreatic Malignancy.

Authors:  Seong-Hun Kim; Eun Ji Shin
Journal:  Clin Endosc       Date:  2021-05-28

3.  An evaluation of systematic errors on marker-based registration of computed tomography and magnetic resonance images of the liver.

Authors:  Thomas Woolcot; Evanthia Kousi; Emma Wells; Katharine Aitken; Helen Taylor; Maria A Schmidt
Journal:  Phys Imaging Radiat Oncol       Date:  2018-09-06

Review 4.  MR-Guided Radiotherapy for Liver Malignancies.

Authors:  Luca Boldrini; Stefanie Corradini; Cihan Gani; Lauren Henke; Ali Hosni; Angela Romano; Laura Dawson
Journal:  Front Oncol       Date:  2021-04-01       Impact factor: 6.244

  4 in total