Literature DB >> 7863615

Discrimination of position and contrast in amblyopic and peripheral vision.

D M Levi1, S A Klein, H Wang.   

Abstract

Many computational models of normal vernier acuity make predictions based on the just-noticeable contrast difference. Recently, Hu, Klein and Carney [(1993) Vision Research, 33, 1241-1258] compared vernier acuity and contrast discrimination (jnd) in normal foveal viewing using cosine gratings. In the jnd stimulus the test grating was added in-phase to the (sinusoidal) pedestal, whereas in the vernier stimulus the same test grating was added with an approx. 90 deg phase shift to the pedestal. In the present experiments, we measured thresholds for discriminating changes in relative position and changes in relative contrast for abutting, horizontal cosine gratings in a group of amblyopes using the Hu et al., test-pedestal approach. The approach here is to ask whether the reduced vernier acuity of amblyopes can be understood on the basis of reduced contrast sensitivity or contrast discrimination. Our results show that (i) abutting cosine vernier acuity is strongly dependent on stimulus contrast. (ii) In both anisometropic and strabismic amblyopes, abutting cosine vernier discrimination thresholds are elevated at all contrast levels, even after accounting for reduced target visibility, or contrast discrimination. (iii) For both strabismic and anisometropic amblyopes, the vernier Weber fraction is markedly degraded, while the contrast Weber fraction is normal or nearly so. (iv) In anisometropic amblyopes the elevated vernier thresholds are consistent with the observers' reduced cutoff spatial frequency, i.e. the loss can be accounted for on the basis of a shift in spatial scale. (v) In strabismic amblyopes and in the normal periphery, there appears to be an extra loss, which can not be accounted for by either reduced contrast sensitivity and contrast discrimination or by a shift in spatial scale. (vi) This extra loss cannot be quantitatively mimicked by "undersampling" the stimulus. (vii) Surprisingly, in some strabismics, and in the periphery, at relatively high spatial frequencies, vernier thresholds appear to lose their contrast dependence, suggesting the possibility that there may be qualitative differences between the normal fovea and these degraded visual systems. (viii) This contrast saturation can be mimicked by "undersampling" the target, or by introducing strips of mean luminance between the two vernier gratings, thus mimicking a "scotoma". Taken together with the preceding paper, our results suggest that the extra loss in position acuity of strabismic amblyopes and the normal periphery may be a consequence of noise at a second stage of processing, which selectively degrades position but not contrast discrimination.

Entities:  

Mesh:

Year:  1994        PMID: 7863615     DOI: 10.1016/0042-6989(94)90066-3

Source DB:  PubMed          Journal:  Vision Res        ISSN: 0042-6989            Impact factor:   1.886


  8 in total

Review 1.  Linking assumptions in amblyopia.

Authors:  Dennis M Levi
Journal:  Vis Neurosci       Date:  2013-07-24       Impact factor: 3.241

2.  Effects of anisometropic amblyopia on visuomotor behavior, I: saccadic eye movements.

Authors:  Ewa Niechwiej-Szwedo; Herbert C Goltz; Manokaraananthan Chandrakumar; Zahra A Hirji; Agnes M F Wong
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-07-29       Impact factor: 4.799

3.  Noise provides some new signals about the spatial vision of amblyopes.

Authors:  Dennis M Levi; Stanley A Klein
Journal:  J Neurosci       Date:  2003-04-01       Impact factor: 6.167

4.  The response of the amblyopic visual system to noise.

Authors:  Dennis M Levi; Stanley A Klein; Inning Chen
Journal:  Vision Res       Date:  2007-08-13       Impact factor: 1.886

5.  Feasibility, detectability and clinical experience with platinum fiducial seeds for MRI/CT fusion and real-time tumor tracking during CyberKnife® stereotactic ablative radiotherapy.

Authors:  Vimoj J Nair; Janos Szanto; Eric Vandervoort; Elizabeth Henderson; Leonard Avruch; Shawn Malone; Pantarotto Jason R
Journal:  J Radiosurg SBRT       Date:  2015

6.  The effect of sensory uncertainty due to amblyopia (lazy eye) on the planning and execution of visually-guided 3D reaching movements.

Authors:  Ewa Niechwiej-Szwedo; Herbert C Goltz; Manokaraananthan Chandrakumar; Agnes M F Wong
Journal:  PLoS One       Date:  2012-02-17       Impact factor: 3.240

7.  Monocular blur alters the tuning characteristics of stereopsis for spatial frequency and size.

Authors:  Roger W Li; Kayee So; Thomas H Wu; Ashley P Craven; Truyet T Tran; Kevin M Gustafson; Dennis M Levi
Journal:  R Soc Open Sci       Date:  2016-09-21       Impact factor: 2.963

8.  Cortical sources of Vernier acuity in the human visual system: An EEG-source imaging study.

Authors:  Chuan Hou; Yee-Joon Kim; Preeti Verghese
Journal:  J Vis       Date:  2017-06-01       Impact factor: 2.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.