Dear Editor, We read with great interest the article by Calvo-Sanz et al. comparing specular microscopy (SM) with OCT and ultrasound pachymetry (USP). We would like to congratulate with the authors for their excellent paper, because even if corneal thickness (CT) is not the only parameter involved in the reliability of intraocular pressure measurement, a precise CT measurement is very important both in establishing the corneal health and in evaluating the intraocular pressure. Their paper confirms our belief that SM measurements are in absolute thinner compared to other devices.5, 6 In fact in a previous paper De Bernardo et al. found that CT obtained with this device was thinner than the measurements obtained with Pentacam, and they proposed a regression formula to make the measurements comparable. We agree with the authors that USP measurements depend on the exact axial placement of the probe making the reproducibility of measurements dependent on examiner expertise. Concerning the difference between USP and SM, the authors performed the USP after the instillation of topical anesthesia utilizing a combination of 0.1% tetracaine and 0.4% oxybuprocaine. Theoretically this could have given some differences, because it is true that in a previous published paper it has been demonstrated no influence on CT and volume measurements with the instillation of oxybuprocaine eye drops, but tetracaine eye drops have been described to cause corneal thickening. So in conclusion we would like to suggest that for future works concerning the comparison of different devices the use of oxybuprocaine, better if preservative free, instead of tetracaine should be advisable.

Funding

None.
  10 in total

1.  Corneal parameters and difference between goldmann applanation tonometry and dynamic contour tonometry in normal eyes.

Authors:  Michele Lanza; Maria Borrelli; Maddalena De Bernardo; Maria Luisa Filosa; Nicola Rosa
Journal:  J Glaucoma       Date:  2008-09       Impact factor: 2.503

2.  Central corneal thickness determination in corneal edema.

Authors:  Nicola Rosa; Maddalena De Bernardo
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-03-15       Impact factor: 3.117

3.  Central Corneal Thickness After Cross-linking Using High-Definition Optical Coherence Tomography, Ultrasound, and Dual Scheimpflug Tomography: A Comparative Study Over One Year.

Authors:  Maddalena De Bernardo; Nicola Rosa
Journal:  Am J Ophthalmol       Date:  2017-01-31       Impact factor: 5.258

4.  Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery.

Authors:  Maddalena De Bernardo; Nicola Rosa
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-02-03       Impact factor: 3.117

5.  Evaluation of the comparative effect of tetracaine on central corneal thickness measured by a contact and noncontact pachymeter.

Authors:  Uchechukwu L Osuagwu; Kelechi C Ogbuehi
Journal:  J Ocul Pharmacol Ther       Date:  2012-10-11       Impact factor: 2.671

6.  Pentacam vs SP3000P specular microscopy in measuring corneal thickness.

Authors:  Maddalena De Bernardo; Maria Borrelli; Marco Mariniello; Michele Lanza; Nicola Rosa
Journal:  Cont Lens Anterior Eye       Date:  2014-09-17       Impact factor: 3.077

7.  Effect of oxybuprocaine eye drops on corneal volume and thickness measurements.

Authors:  Nicola Rosa; Maddalena De Bernardo; Maria Borrelli; Maria Luisa Filosa; Michele Lanza
Journal:  Optom Vis Sci       Date:  2011-05       Impact factor: 1.973

8.  Corneal thickness and endothelial cell characteristics in patients with myotonic dystrophy.

Authors:  Nicola Rosa; Michele Lanza; Maria Borrelli; Maria Luisa Filosa; Maddalena De Bernardo; Vega Maria Ventriglia; Maria Rosaria Cecio; Luisa Politano
Journal:  Ophthalmology       Date:  2009-12-06       Impact factor: 12.079

9.  Intraocular pressure and corneal biomechanical properties in patients with myotonic dystrophy.

Authors:  Nicola Rosa; Michele Lanza; Maria Borrelli; Alberto Palladino; M Grazia Di Gregorio; Luisa Politano
Journal:  Ophthalmology       Date:  2008-11-18       Impact factor: 12.079

10.  Accuracy of Cirrus HD-OCT and Topcon SP-3000P for measuring central corneal thickness.

Authors:  Jorge A Calvo-Sanz; Javier Ruiz-Alcocer; Miguel A Sánchez-Tena
Journal:  J Optom       Date:  2017-02-21
  10 in total
  1 in total

1.  Monitoring of central corneal thickness after phacoemulsification-comparison of statical and rotating Scheimpflug pachymetry, and spectral-domain OCT.

Authors:  Daniel M Handzel; Carsten H Meyer; Alfred Wegener
Journal:  Int J Ophthalmol       Date:  2022-08-18       Impact factor: 1.645

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.