Literature DB >> 18794680

Corneal parameters and difference between goldmann applanation tonometry and dynamic contour tonometry in normal eyes.

Michele Lanza1, Maria Borrelli, Maddalena De Bernardo, Maria Luisa Filosa, Nicola Rosa.   

Abstract

PURPOSE: To compare the difference between 2 methods of measuring the intraocular pressure (IOP), namely, Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT) and to study the relationship with the corneal parameters in patients with no glaucoma signs.
METHODS: One hundred and eighteen eyes of 118 healthy subjects from 20 to 77 years of age underwent IOP measurements with DCT and GAT, central corneal thickness, and corneal volume measurements with Pentacam Scheimpflug camera. Pentacam examination has been performed first, then DCT and, after 10 minutes, GAT measurements.
RESULTS: The measurements with GAT ranged between 11 and 22 mm Hg (m=15.49+/-2.43 mm Hg), the measurements with DCT ranged between 10.5 and 25.1 mm Hg (m=17.59+/-2.9 mm Hg). DCT showed a statistically significant (P<0.0001) higher IOP measurement compared with GAT. A relation between differences in IOP with central corneal thickness and corneal volume was found, whereas no relation was found with corneal radius and age.
CONCLUSIONS: Our results show a discrete correlation between GAT and DCT measurements, but DCT showed slightly higher values of IOP. If DCT should be considered the gold standard, higher values of IOP could still be considered normal. These 2 devices cannot to be used interchangeably.

Entities:  

Mesh:

Year:  2008        PMID: 18794680     DOI: 10.1097/IJG.0b013e31816224bd

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  13 in total

1.  Central corneal thickness determination in corneal edema.

Authors:  Nicola Rosa; Maddalena De Bernardo
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-03-15       Impact factor: 3.117

2.  Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery.

Authors:  Maddalena De Bernardo; Nicola Rosa
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-02-03       Impact factor: 3.117

3.  Dependence of dynamic contour and Goldmann applanation tonometries on peripheral corneal thickness.

Authors:  Federico Saenz-Frances; Claudia Sanz-Pozo; Lara Borrego-Sanz; Luis Jañez; Laura Morales-Fernandez; Jose Maria Martinez-de-la-Casa; Julian Garcia-Sanchez; Julian Garcia-Feijoo; Enrique Santos-Bueso
Journal:  Int J Ophthalmol       Date:  2017-10-18       Impact factor: 1.779

4.  Comparison of Goldmann and Pascal tonometry in relation to corneal hysteresis and central corneal thickness in nonglaucomatous eyes.

Authors:  G Mangouritsas; S Mourtzoukos; A Mantzounis; L Alexopoulos
Journal:  Clin Ophthalmol       Date:  2011-08-03

5.  Comparison of Goldmann applanation tonometry and Pascal dynamic contour tonometry in relation to central corneal thickness and corneal curvature.

Authors:  Konstantinos Andreanos; Chryssanthi Koutsandrea; Dimitris Papaconstantinou; Andreas Diagourtas; Andreas Kotoulas; Panagiotis Dimitrakas; Marilita M Moschos
Journal:  Clin Ophthalmol       Date:  2016-12-09

6.  Central corneal thickness measurement with different devices in keratoconic patients.

Authors:  Maddalena De Bernardo; Nicola Rosa
Journal:  J Curr Ophthalmol       Date:  2017-12-06

7.  Reply to comment by De Bernardo and Rosa on "Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus".

Authors:  Fatih Özcura; Nilgün Yıldırım
Journal:  J Optom       Date:  2017-12-15

8.  Central corneal thickness measurement with Cirrus HD-OCT and Topcon SP-3000P.

Authors:  Maddalena De Bernardo; Francesco Antonio Salzano; Nicola Rosa
Journal:  J Optom       Date:  2017-12-14

9.  Tonometry in corneal edema after cataract surgery: dynamic contour tonometry versus Goldmann applanation tonometry.

Authors:  Anne Herr; Andreas Remky; Thalia Hirsch; Corinna Rennings; Niklas Plange
Journal:  Clin Ophthalmol       Date:  2013-05-03

10.  Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus.

Authors:  Maddalena De Bernardo; Nicola Rosa
Journal:  J Optom       Date:  2018-02-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.