Literature DB >> 29242756

Intersession Test-Retest Variability of Microperimetry in Type 2 Macular Telangiectasia.

Evan N Wong1,2, Jehan D A De Soyza2, David A Mackey1, Ian J Constable1,3, Fred K Chen1,2.   

Abstract

PURPOSE: Microperimetry is used as an endpoint in type 2 macular telangiectasia (mactel) trials. The change required for defining disease progression depends on measurement error. We determined the threshold of test-retest variability (TRV) of microperimetry in mactel.
METHODS: A prospective study was done of 24 patients with stable mactel enrolled in a tertiary eye clinic. Each patient underwent three sessions of microperimetry separated by a median of 28 days. An identical testing protocol was used: 4-2 staircase algorithm at 37 loci radial grid covering central 6°. Microperimetry variables were compared across three visits. TRV was quantified by calculating the coefficients of repeatability (CRs) for mean and median foveal sensitivity and the number of loci with dense scotoma (DS) or normal sensitivity (NS). The 95% confidence intervals (CIs) for CRs were calculated.
RESULTS: Mean and median foveal sensitivity increased from first to second testing sessions. Test duration, visual acuity, number of loci with DS, and fixation stability remained stable through the three test sessions. The intersession CRs for mean and median foveal sensitivity were 2.6 (95% CI, 1.8-3.3) and 2.4 (95% CI, 1.7-3.1) dB, respectively. CRs for the number of DS and NS loci were 5 and 12 loci. CR for both logBCEA63 and logBCEA95 was 1.0 (95% CI, 0.8-1.2).
CONCLUSIONS: The first microperimetry examination should be discarded due to learning effects. TRV in foveal sensitivity may be as high as 3.3 and 3.1 dB (∼0.3 log unit; 2× change) for its mean and median. TRANSLATIONAL RELEVANCE: Our results have implications for the design of clinical trials in mactel.

Entities:  

Keywords:  MAIA microperimetry; fixation stability; measurement error; repeatability; retinal sensitivity; scotoma

Year:  2017        PMID: 29242756      PMCID: PMC5727942          DOI: 10.1167/tvst.6.6.7

Source DB:  PubMed          Journal:  Transl Vis Sci Technol        ISSN: 2164-2591            Impact factor:   3.283


  25 in total

1.  Reliability and Intersession Agreement of Microperimetric and Fixation Measurements Obtained with a New Microperimeter in Normal Eyes.

Authors:  Ainhoa Molina-Martín; David P Piñero; Rafael J Pérez-Cambrodí
Journal:  Curr Eye Res       Date:  2015-04-10       Impact factor: 2.424

2.  Macular retinal sensitivity using MP-1 in healthy Malaysian subjects of different ages.

Authors:  Siti Aishah Ismail; Haliza Abdul Mutalib; Nor Fariza Ngah
Journal:  J Optom       Date:  2015-05-27

3.  Macular function in macular degenerations: repeatability of microperimetry as a potential outcome measure for ABCA4-associated retinopathy trials.

Authors:  Artur V Cideciyan; Malgorzata Swider; Tomas S Aleman; Willam J Feuer; Sharon B Schwartz; Robert C Russell; Janet D Steinberg; Edwin M Stone; Samuel G Jacobson
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-02-21       Impact factor: 4.799

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Clinical value, normative retinal sensitivity values, and intrasession repeatability using a combined spectral domain optical coherence tomography/scanning laser ophthalmoscope microperimeter.

Authors:  A Anastasakis; J J McAnany; G A Fishman; W H Seiple
Journal:  Eye (Lond)       Date:  2010-10-29       Impact factor: 3.775

6.  Long- and short-term variability of automated perimetry results in patients with optic neuritis and healthy subjects.

Authors:  M Wall; C A Johnson; K E Kutzko; R Nguyen; C Brito; J L Keltner
Journal:  Arch Ophthalmol       Date:  1998-01

7.  Correlation of macular function with retinal thickness in nonproliferative type 2 idiopathic macular telangiectasia.

Authors:  Peter Charbel Issa; Hans-Martin Helb; Frank G Holz; Hendrik P N Scholl
Journal:  Am J Ophthalmol       Date:  2007-11-05       Impact factor: 5.258

8.  Reading performance is reduced by parafoveal scotomas in patients with macular telangiectasia type 2.

Authors:  Robert P Finger; Peter Charbel Issa; Rolf Fimmers; Frank G Holz; Gary S Rubin; Hendrik P N Scholl
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-11-07       Impact factor: 4.799

9.  Idiopathic juxtafoveolar retinal telangiectasis.

Authors:  J D Gass; R T Oyakawa
Journal:  Arch Ophthalmol       Date:  1982-05

10.  Intersession test-retest variability of conventional and novel parameters using the MP-1 microperimeter.

Authors:  Evan N Wong; David A Mackey; William H Morgan; Fred Kuanfu Chen
Journal:  Clin Ophthalmol       Date:  2015-12-23
View more
  4 in total

1.  Retinal AAV8-RS1 Gene Therapy for X-Linked Retinoschisis: Initial Findings from a Phase I/IIa Trial by Intravitreal Delivery.

Authors:  Catherine Cukras; Henry E Wiley; Brett G Jeffrey; H Nida Sen; Amy Turriff; Yong Zeng; Camasamudram Vijayasarathy; Dario Marangoni; Lucia Ziccardi; Sten Kjellstrom; Tae Kwon Park; Suja Hiriyanna; J Fraser Wright; Peter Colosi; Zhijian Wu; Ronald A Bush; Lisa L Wei; Paul A Sieving
Journal:  Mol Ther       Date:  2018-07-07       Impact factor: 11.454

2.  Estimating Retinal Sensitivity Using Optical Coherence Tomography With Deep-Learning Algorithms in Macular Telangiectasia Type 2.

Authors:  Yuka Kihara; Tjebo F C Heeren; Cecilia S Lee; Yue Wu; Sa Xiao; Simone Tzaridis; Frank G Holz; Peter Charbel Issa; Catherine A Egan; Aaron Y Lee
Journal:  JAMA Netw Open       Date:  2019-02-01

3.  Long-Term Effects of Half-Time Photodynamic Therapy on Retinal Sensitivity in Eyes with Chronic Central Serous Chorioretinopathy.

Authors:  Takehito Iwase; Hirotaka Yokouchi; Masayasu Kitahashi; Mariko Kubota-Taniai; Takayuki Baba; Shuichi Yamamoto
Journal:  Biomed Res Int       Date:  2020-08-17       Impact factor: 3.411

Review 4.  Clinical Perspectives and Trends: Microperimetry as a Trial Endpoint in Retinal Disease.

Authors:  Yesa Yang; Hannah Dunbar
Journal:  Ophthalmologica       Date:  2021-02-10       Impact factor: 3.250

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.