Literature DB >> 25859613

Reliability and Intersession Agreement of Microperimetric and Fixation Measurements Obtained with a New Microperimeter in Normal Eyes.

Ainhoa Molina-Martín1, David P Piñero2,3, Rafael J Pérez-Cambrodí2.   

Abstract

PURPOSE: To evaluate the reliability and intersession agreement of measurements of retinal sensitivity as well as of the fixation pattern obtained in healthy eyes with a microperimeter integrating the mechanism of the scanning laser ophthalmoscope (SLO) with the static perimetry.
METHODS: This study included a sample of 44 healthy eyes of 44 subjects of a mean age of 27.0 ± 8.5 years. In all cases, microperimetric exams with the MAIA system (Centervue, Padova, Italy) were performed in three different sessions to evaluate the intersession repeatability. The consistency of measurements was analyzed by using the Friedman test and by analyzing the correlation between consecutive measurements. Agreement between the first and third sessions was assessed by using the Passing-Bablok regression analysis. The following parameters were analyzed: average threshold (AT), macular integrity (MI) index, fixation indexes P1 and P2, bivariate contour ellipse area (BCEA), major and minor axes of the ellipse and high preferred retinal locus position (PRLh).
RESULTS: Not statistically significant differences were found in the evaluated parameters between the three sessions (p ≥ 0.193). The correlation between consecutive measurements was moderate to strong for all parameters evaluated (r ≥ 0.49, p < 0.01), except for the MI and the position of the PRLh (r ≤ 0.305, p ≥ 0.05). The Passing-Bablok regression analysis showed a good agreement between the first and third measurement for all parameters, except for the MI and the position of the PRLh.
CONCLUSION: MAIA MP system is able to provide consistent measurements of AT and fixation in normal subjects. MI and the position of PRLh seem to be the least reliable parameters in this group of patients.

Entities:  

Keywords:  Fixation; MAIA; microperimeter; microperimetry; preferred retinal locus

Mesh:

Year:  2015        PMID: 25859613     DOI: 10.3109/02713683.2015.1020170

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  10 in total

1.  Impact of Reference Center Choice on Adaptive Optics Imaging Cone Mosaic Analysis.

Authors:  Danial Roshandel; Danuta M Sampson; David A Mackey; Fred K Chen
Journal:  Invest Ophthalmol Vis Sci       Date:  2022-04-01       Impact factor: 4.925

2.  Intersession test-retest variability of 10-2 MAIA microperimetry in fixation-threatening glaucoma.

Authors:  Evan N Wong; William H Morgan; Fred K Chen
Journal:  Clin Ophthalmol       Date:  2017-04-20

3.  Fixation Characteristics in Highly Myopic Eyes: the Shanghai High Myopia Study.

Authors:  Xiangjia Zhu; Wenwen He; Keke Zhang; Yinglei Zhang; Qi Fan; Yi Lu
Journal:  Sci Rep       Date:  2019-04-24       Impact factor: 4.379

4.  Interocular Symmetry of Fixation, Optic Disc, and Corneal Astigmatism in Bilateral High Myopia: The Shanghai High Myopia Study.

Authors:  Xiangjia Zhu; Wenwen He; Yu Du; Keke Zhang; Yi Lu
Journal:  Transl Vis Sci Technol       Date:  2019-02-13       Impact factor: 3.283

5.  Visual rehabilitation using video game stimulation for Stargardt disease.

Authors:  Dhanashree Ratra; Archayeeta Rakshit; Vineet Ratra
Journal:  Ther Adv Ophthalmol       Date:  2019-03-09

6.  Presymptomatic Retinal Sensitivity Changes in Intermediate Age-Related Macular Degeneration Associated With New Retinal Fluid.

Authors:  Antony J Wightman; Carla J Abbott; Myra B McGuinness; Emily Caruso; Robyn H Guymer; Chi D Luu
Journal:  Transl Vis Sci Technol       Date:  2019-11-12       Impact factor: 3.283

7.  Intersession test-retest variability of conventional and novel parameters using the MP-1 microperimeter.

Authors:  Evan N Wong; David A Mackey; William H Morgan; Fred Kuanfu Chen
Journal:  Clin Ophthalmol       Date:  2015-12-23

8.  Edge of Scotoma Sensitivity as a Microperimetry Clinical Trial End Point in USH2A Retinopathy.

Authors:  Jason Charng; Tina M Lamey; Jennifer A Thompson; Terri L McLaren; Mary S Attia; Ian L McAllister; Ian J Constable; David A Mackey; John N De Roach; Fred K Chen
Journal:  Transl Vis Sci Technol       Date:  2020-09-09       Impact factor: 3.283

9.  Interpreting MAIA Microperimetry Using Age- and Retinal Loci-Specific Reference Thresholds.

Authors:  Jason Charng; Paul G Sanfilippo; Mary S Attia; Monika Dolliver; Sukanya Arunachalam; Avenell L Chew; Evan N Wong; David A Mackey; Fred K Chen
Journal:  Transl Vis Sci Technol       Date:  2020-06-18       Impact factor: 3.283

10.  Intersession Test-Retest Variability of Microperimetry in Type 2 Macular Telangiectasia.

Authors:  Evan N Wong; Jehan D A De Soyza; David A Mackey; Ian J Constable; Fred K Chen
Journal:  Transl Vis Sci Technol       Date:  2017-12-12       Impact factor: 3.283

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.