PURPOSE: To describe surgical outcomes and structural characteristics of intraocular lenses (IOLs) implanted with transconjunctival sutureless intrascleral (SIS) fixation in human eyes.
DESIGN: Retrospective interventional surgical case series involving live and cadaveric human eyes.
METHODS: In this study, we investigated the surgical outcomes and structural anatomy of secondary IOLs implanted with the SIS technique in human eyes. All cases involving SIS IOL fixation performed at a single academic center from January 1, 2012, through July 30, 2016, were reviewed to describe the surgical technique, common indications, clinical outcomes, and the rate of common operative complications. To investigate the structure of SIS-fixated IOLs in vivo, slit-lamp biomicroscopy, ultrasound biomicroscopy, and intraoperative endoscopy were analyzed to describe anatomical outcomes. The primary anatomical outcomes were the optic pupillary centration and location of haptic externalization. Results were correlated with cadaveric human eyes that underwent the SIS-IOL technique. Cadaveric eyes were imaged and analyzed using high-resolution photography for centration, stress measurements at the haptic-optic junction, and qualitative descriptors of IOL optic and haptic position.
RESULTS: A total of 122 consecutive patients who underwent IOL placement using SIS technique were included in the study with mean follow-up of 1.52 years (range, 0.4-4.5 years). The majority (75%) of patients received a new 3-piece IOL for primary aphakia or after IOL exchange. The other patients (25%) had a dislocated 3-piece IOL that was rescued using the SIS technique. Preoperative mean Snellen visual acuity was 20/633 (logarithm of the minimum angle of resolution = 1.501). At the final visit, the mean best-corrected visual acuity was 20/83 (logarithm of the minimum angle of resolution = 0.6243) and final mean spherical equivalent was -0.57 diopters. The most common complications were vitreous hemorrhage (22% of eyes), which resolved spontaneously in most cases, and cystoid macular edema. The rates of IOL dislocation, IOL decentration, haptic erosion, IOL tilting, iris capture, and endophthalmitis were low. Intraoperative endoscopy and ultrasound biomicroscopy demonstrated a securely fixated IOL and well-centered optic without iris or ciliary body touch. Structural study of cadaveric eyes confirmed IOL optic and haptic anatomy observed during live human surgery. The ab interno haptic insertion was the anterior pars plana, away from the iris, ciliary processes and ora serrata. The degree of haptic externalization was correlated with the degree of strain on the haptic-optic junction. The angle of the haptic-optic junction in SIS-fixated IOLs (33.97°) was not significantly different compared with overlaid native nonfixated IOL (32.93°) but increased slightly with degree of haptic tip externalization (36.26 and 39.16 for 2 and 3 mm haptic externalizations, respectively).
CONCLUSION: In this comprehensive study, we demonstrate the surgical outcomes achieved with SIS fixation of IOLs. Surgical and postoperative complications do occur, albeit at a low rate, and can effectively be managed with excellent anatomical and visual outcomes. The structural and anatomical data in this study may help guide SIS placement and optimize long-term surgical results.

Entities:  

Mesh:

Year:  2018        PMID: 29232333      PMCID: PMC6120757          DOI: 10.1097/IAE.0000000000001941

Source DB:  PubMed          Journal:  Retina        ISSN: 0275-004X            Impact factor:   4.256


  10 in total

1.  A novel approach for posterior chamber intraocular lens placement or rescue via a sutureless scleral fixation technique.

Authors:  Jonathan L Prenner; Leonard Feiner; H Matthew Wheatley; Daniel Connors
Journal:  Retina       Date:  2012-04       Impact factor: 4.256

2.  Needle-guided intrascleral fixation of posterior chamber intraocular lens for aphakia correction.

Authors:  Iñaki Rodríguez-Agirretxe; Arantxa Acera-Osa; Marta Ubeda-Erviti
Journal:  J Cataract Refract Surg       Date:  2009-12       Impact factor: 3.351

3.  Intermediate results of sutureless intrascleral posterior chamber intraocular lens fixation.

Authors:  Gabor B Scharioth; Som Prasad; Ilias Georgalas; Calin Tataru; Mitrofanis Pavlidis
Journal:  J Cataract Refract Surg       Date:  2010-02       Impact factor: 3.351

4.  Secondary implantation of angle-supported anterior chamber and scleral-fixated posterior chamber intraocular lenses.

Authors:  R Bellucci; V Pucci; S Morselli; L Bonomi
Journal:  J Cataract Refract Surg       Date:  1996-03       Impact factor: 3.351

5.  Sutureless scleral fixation of intraocular lenses: outcomes of two approaches. The 2014 Yasuo Tano Memorial Lecture.

Authors:  Ashkan M Abbey; Rehan M Hussain; Ankoor R Shah; Lisa J Faia; Jeremy D Wolfe; George A Williams
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-11-04       Impact factor: 3.117

6.  Transconjunctival sutureless haptic fixation of posterior chamber IOL: a minimally traumatic approach for IOL rescue or secondary implantation.

Authors:  Som Prasad
Journal:  Retina       Date:  2013-03       Impact factor: 4.256

7.  Extraocular Technique of Intrascleral Intraocular Lens Fixation Using a Pair of the Shaft-Bended 27-Gauge Needles.

Authors:  Ichiro Maruko; Hideki Koizumi; Akiko Kogure-Katakura; Tomohiro Iida
Journal:  Retina       Date:  2017-01       Impact factor: 4.256

8.  Outcomes of iris-claw anterior chamber versus iris-fixated foldable intraocular lens in subluxated lens secondary to Marfan syndrome.

Authors:  Denise E Hirashima; Eduardo S Soriano; Rodrigo L Meirelles; Gustave N Alberti; Walton Nosé
Journal:  Ophthalmology       Date:  2010-05-13       Impact factor: 12.079

9.  Sutureless Intrascleral Fixation of Secondary Intraocular Lens Using 27-Gauge Vitrectomy System.

Authors:  Bozho Todorich; Aristomenis Thanos; Maria A Woodward; Jeremy D Wolfe
Journal:  Ophthalmic Surg Lasers Imaging Retina       Date:  2016-04-01       Impact factor: 1.300

10.  Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection.

Authors:  Shin Yamane; Maiko Inoue; Akira Arakawa; Kazuaki Kadonosono
Journal:  Ophthalmology       Date:  2013-10-20       Impact factor: 12.079

  10 in total
  12 in total

1.  Scleral Fixation of Intraocular Lenses with Gore-Tex Suture: Refractive Outcomes and Comparison of Lens Power Formulas.

Authors:  Benjamin W Botsford; Andrew M Williams; Ian P Conner; Joseph N Martel; Andrew W Eller
Journal:  Ophthalmol Retina       Date:  2019-02-19

2.  27-GAUGE SUTURELESS INTRASCLERAL FIXATION OF INTRAOCULAR LENSES WITH HAPTIC FLANGING: Short-Term Clinical Outcomes and a Disinsertion Force Study.

Authors:  Maxwell S Stem; Christianne A Wa; Bozho Todorich; Maria A Woodward; Mark K Walsh; Jeremy D Wolfe
Journal:  Retina       Date:  2019-11       Impact factor: 4.256

3.  [Complications in sutured scleral fixation of artificial lens implantation].

Authors:  Lisa Brandt; Jörgen Petersen; Josep Callizo; Sebastian Bemme; Sebastian Pfeiffer; Hans Hoerauf; Nicolas Feltgen; Christian van Oterendorp
Journal:  Ophthalmologe       Date:  2019-12       Impact factor: 1.059

4.  Sutureless scleral fixation: comparison between 3-piece IOL and new single-piece foldable IOL.

Authors:  Isabella D'Agostino; Salvatore Parrulli; Stefano De Angelis; Alessandro Invernizzi; Ferdinando Bottoni; Giovanni Staurenghi; Matteo Giuseppe Cereda
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-10-22       Impact factor: 3.117

5.  Refractive errors after sutureless intrascleral fixation of intraocular lens.

Authors:  Masato Kakisu; Takayuki Baba; Tomoaki Tatsumi; Takehito Iwase; Tomohiro Nizawa; Gen Miura; Shuichi Yamamoto
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-06-18       Impact factor: 3.117

6.  Flanged intraocular lens fixation via 27-gauge trocars using a double-needle technique decreases surgical wounds without losing its therapeutic effect.

Authors:  Hiroto Ishikawa; Hisashi Fukuyama; Yuki Komuku; Takashi Araki; Fumi Gomi
Journal:  Acta Ophthalmol       Date:  2019-11-17       Impact factor: 3.761

7.  Sutureless Scleral Fixated IOL: The "Catcher Pole" Technique.

Authors:  Ciro Tamburrelli; Anna Clara Tamburrelli
Journal:  Clin Ophthalmol       Date:  2021-01-12

8.  Scleral Fixation of a Hydrophobic Acrylic Intraocular Lens with Eyelets Using 8-0 Polypropylene Suture.

Authors:  Do Wook Kim; Sung Chul Lee; Ji Hwan Lee
Journal:  Korean J Ophthalmol       Date:  2021-11-08

9.  A modified intrascleral intraocular lens fixation technique with fewer anterior segment manipulations: 27-gauge needle-guided procedure with built-in 8-0 absorbable sutures.

Authors:  Yuan Yang; Teng-Teng Yao; Ya-Li Zhou; Yi-Xiao Wang; Zhao-Yang Wang
Journal:  BMC Ophthalmol       Date:  2019-11-21       Impact factor: 2.209

10.  Outcomes and Complications of Sutured Scleral-Fixated Foldable Intraocular Lens Implantation: A Retrospective Study of 5-Year Follow-Up.

Authors:  Ting Yu; Mengting Yu; Wenjie Wu; Xinna Wu; Suzhen Xiao; Jialiang Mao; Yanling Wang
Journal:  J Ophthalmol       Date:  2021-07-16       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.