Literature DB >> 24148655

Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection.

Shin Yamane1, Maiko Inoue2, Akira Arakawa2, Kazuaki Kadonosono2.   

Abstract

PURPOSE: To report a new technique for performing sutureless intrascleral fixation of a posterior chamber intraocular lens (IOL).
DESIGN: Prospective, noncomparative, interventional case series on the results of sutureless intrascleral fixation of a posterior chamber IOL. PARTICIPANTS: Thirty-five eyes of 34 consecutive patients with aphakia, dislocated IOL, or subluxated crystalline lens who underwent posterior chamber sutureless implantation of an IOL were studied.
METHODS: The haptics of the IOL were externalized with a 27-gauge needle passed through the ciliary sulcus using the double needle technique. The haptics were fixed in a scleral tunnel made by lamellar scleral dissection. The postoperative tilt of the IOL was measured by swept source optical coherence tomography. MAIN OUTCOME MEASURES: The best-corrected visual acuity (BCVA), corneal endothelial cell density, IOL tilt, and complications were determined.
RESULTS: The IOLs were fixed with exact centration and axial stability. No wound leakage was seen even without any sutures. The mean BCVA was 0.48 logarithm of the minimum angle of resolution (logMAR) units preoperatively and 0.17 logMAR units at 3 months postoperatively (P = 0.003). The mean corneal endothelial cell loss was 6.0±7.3% (P = 0.63) at 3 months. The mean IOL tilt was 2.3±1.9°. The postoperative complications included iris capture by the IOL in 3 eyes (8.6%), ocular hypertension in 2 (5.7%), and cystoid macular edema in 1 (2.9%). There was no postoperative retinal detachment, endophthalmitis, IOL dislocation, or vitreous hemorrhage.
CONCLUSIONS: The 27-gauge needle-guided intrascleral posterior chamber IOL implantation technique provides good IOL fixation with reliable wound closure without the use of any sutures. We recommend this technique for secondary IOL implantation.
Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 24148655     DOI: 10.1016/j.ophtha.2013.08.043

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  63 in total

1.  A safe method of ciliary sulcus fixation of foldable intraocular lens using a ciliary sulcus guide.

Authors:  Ertuğrul Can; Adem Gül; Hakkı Birinci
Journal:  Int Ophthalmol       Date:  2015-10-06       Impact factor: 2.031

2.  The effect of intraocular lens tilt on visual outcomes in scleral-fixated intraocular lens implantation.

Authors:  Burcu Kemer Atik; Cigdem Altan; Alper Agca; Asli Kirmaci; Yusuf Yildirim; Selim Genc; Muhittin Taskapili
Journal:  Int Ophthalmol       Date:  2019-11-23       Impact factor: 2.031

3.  Scleral Fixation of Intraocular Lenses with Gore-Tex Suture: Refractive Outcomes and Comparison of Lens Power Formulas.

Authors:  Benjamin W Botsford; Andrew M Williams; Ian P Conner; Joseph N Martel; Andrew W Eller
Journal:  Ophthalmol Retina       Date:  2019-02-19

4.  27-GAUGE SUTURELESS INTRASCLERAL FIXATION OF INTRAOCULAR LENSES WITH HAPTIC FLANGING: Short-Term Clinical Outcomes and a Disinsertion Force Study.

Authors:  Maxwell S Stem; Christianne A Wa; Bozho Todorich; Maria A Woodward; Mark K Walsh; Jeremy D Wolfe
Journal:  Retina       Date:  2019-11       Impact factor: 4.256

5.  Reinforced scleral fixation of foldable intraocular lens by double sutures: comparison with intrascleral intraocular lens fixation.

Authors:  Yodpong Chantarasorn; Settapong Techalertsuwan; Pongsavit Siripanthong; Anurak Tamerug
Journal:  Jpn J Ophthalmol       Date:  2018-02-20       Impact factor: 2.447

6.  STRUCTURAL ANALYSIS AND COMPREHENSIVE SURGICAL OUTCOMES OF THE SUTURELESS INTRASCLERAL FIXATION OF SECONDARY INTRAOCULAR LENSES IN HUMAN EYES.

Authors:  Bozho Todorich; Maxwell S Stem; Keshav Kooragayala; Aristomenis Thanos; Lisa J Faia; George A Williams; Tarek S Hassan; Maria A Woodward; Jeremy D Wolfe
Journal:  Retina       Date:  2018-09       Impact factor: 4.256

7.  Ten-year trends in the incidence, clinical profile and outcomes of acute-onset endophthalmitis following combined pars plana vitrectomy and sutureless, glueless and flapless scleral fixation of intraocular lenses.

Authors:  Naresh Babu Kannan; Sagnik Sen; Chitaranjan Mishra; Prajna Lalitha; Gunasekaran Rameshkumar; Karthik Kumar; Renu P Rajan; Kim Ramasamy
Journal:  Int Ophthalmol       Date:  2021-01-29       Impact factor: 2.031

8.  Double-flanged-haptic and capsular tension ring or segment for sutureless fixation in zonular instability.

Authors:  Sergio Canabrava; Leticia Bernardino; Thais Batisteli; Gabriella Lopes; Alberto Diniz-Filho
Journal:  Int Ophthalmol       Date:  2017-10-24       Impact factor: 2.031

9.  Outcomes of a new suture technique for the treatment of dislocated intraocular lenses: locked loop on the haptic.

Authors:  Ugur Unsal; Berkay Akmaz; Deniz Kilic
Journal:  Int Ophthalmol       Date:  2021-06-26       Impact factor: 2.031

10.  Needle infusion avoids using sutures and prevents hypotony in the 23 gauge sutureless vitrectomy.

Authors:  Yingjie Zhang; Dongqing Zhu; Jibo Zhou
Journal:  Int J Clin Exp Med       Date:  2015-10-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.