Literature DB >> 29228469

Simultaneous determination of etonogestrel and ethinyl estradiol in human plasma by UPLC-MS/MS and its pharmacokinetic study.

Sneha G Nair1, Daxesh P Patel1,2, Frank J Gonzalez2, Bhargav M Patel1, Puran Singhal3, Darshan V Chaudhary1,4.   

Abstract

A selective, sensitive and rapid ultra-performance liquid chromatography tandem mass spectrometry method was developed and validated for the simultaneous determination of etonogestrel (ENG) and ethinyl estradiol (EE) in human plasma. The analytes and their deuterated internal standards, ENG-d7 and EE-d4, were extracted from plasma samples by solid-phase extraction on HyperSep™ Retain PEP cartridges. The chromatographic analysis was performed on an Acquity UPLC HSS Cyano column, 100 Å (50 × 2.1 mm, 1.8 μm), column using gradient mobile phase, acetonitrile and 2.0 mm ammonium trifluoroacetate at 0-1.7 min (65:35, v/v) and 1.8-2.7 min (95:5, v/v) with 0.250 mL/min flow rate. Analytes and IS protonated precursor → product ion transitions (ENG, m/z 325.2 → 257.2; EE, m/z 530.2 → 171.2; ENG-d7, m/z 332.2 → 263.2; EE-d4, m/z 534.2 → 171.2) were monitored on a Triple Quadrupole Mass spectrometer (TQMS), operating in multiple reaction monitoring and positive ionization mode. The calibration curves were established at 10.00-2500 pg/mL for ENG and 1.500-150.0 pg/mL for EE with a correlation coefficient (r2 ) ≥0.9996 for both. The validated method was successfully applied to support a bioequivalence study of 0.15 mg ENG and EE 0.03 mg tablet formulation, administered in 24 healthy Indian females. Method reliability was assessed by reanalysis of 94 incurred study samples.
Copyright © 2017 John Wiley & Sons, Ltd.

Entities:  

Keywords:  UPLC-MS/MS; ethinyl estradiol; etonogestrel; human plasma; low pg/mL

Mesh:

Substances:

Year:  2018        PMID: 29228469      PMCID: PMC6643291          DOI: 10.1002/bmc.4165

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  18 in total

1.  Pharmacokinetics of etonogestrel and ethinylestradiol released from a combined contraceptive vaginal ring.

Authors:  C J Timmer; T M Mulders
Journal:  Clin Pharmacokinet       Date:  2000-09       Impact factor: 6.447

2.  Comparison of uterine concentrations of ethinyl estradiol and etonogestrel after use of a contraceptive vaginal ring and an oral contraceptive.

Authors:  Frans J M E Roumen; Thom O M Dieben
Journal:  Fertil Steril       Date:  2006-01       Impact factor: 7.329

3.  Bioequivalence study of generic tablet formulations containing ethinylestradiol and chlormadinone acetate in healthy female volunteers.

Authors:  Michael Bonn; Urte Eydeler; Martin Barkworth; Lucio C Rovati
Journal:  Arzneimittelforschung       Date:  2009

4.  [Simultaneous determination of gestodene, etonogestrel and ethinylestradiol in plasma by LC-MS/MS following derivatization].

Authors:  Xiao-Fen Liu; Cun-Gang Ding; Qing-Hua Ge; Zhen Zhou; Xiao-Jin Zhi
Journal:  Yao Xue Xue Bao       Date:  2010-01

5.  Simultaneous determination of norethindrone and ethinyl estradiol in human plasma by high performance liquid chromatography with tandem mass spectrometry--experiences on developing a highly selective method using derivatization reagent for enhancing sensitivity.

Authors:  Wenkui Li; Ying-He Li; Austin C Li; Shaolian Zhou; Weng Naidong
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2005-10-25       Impact factor: 3.205

6.  Safety and efficacy of Implanon, a single-rod implantable contraceptive containing etonogestrel.

Authors:  Sidney Funk; Michael M Miller; Daniel R Mishell; David F Archer; Alfred Poindexter; Juergen Schmidt; Edio Zampaglione
Journal:  Contraception       Date:  2005-05       Impact factor: 3.375

7.  Development and validation of UPLC-MS/MS method for simultaneous determination of gestodene and ethinyl estradiol in rat plasma.

Authors:  Zhili Xiong; Xiaohong Sun; Taoguang Huo; Ning Li; Yan Zheng; Yi Sun
Journal:  Biomed Chromatogr       Date:  2010-02       Impact factor: 1.902

8.  Development and validation of a high-sensitivity liquid chromatography/tandem mass spectrometry (LC/MS/MS) method with chemical derivatization for the determination of ethinyl estradiol in human plasma.

Authors:  Wilson Z Shou; Xiangyu Jiang; Weng Naidong
Journal:  Biomed Chromatogr       Date:  2004-09       Impact factor: 1.902

9.  Derivatization of ethinylestradiol with dansyl chloride to enhance electrospray ionization: application in trace analysis of ethinylestradiol in rhesus monkey plasma.

Authors:  M Reza Anari; Ray Bakhtiar; Bing Zhu; Su Huskey; Ronald B Franklin; David C Evans
Journal:  Anal Chem       Date:  2002-08-15       Impact factor: 6.986

10.  Bioavailability and bioequivalence of etonogestrel from two oral formulations of desogestrel: Cerazette and Liseta.

Authors:  C J Timmer; N Srivastava; T O Dieben; A F Cohen
Journal:  Eur J Drug Metab Pharmacokinet       Date:  1999 Oct-Dec       Impact factor: 2.569

View more
  1 in total

1.  Interactions between etonogestrel-releasing contraceptive implant and 3 antiretroviral regimens.

Authors:  Regis Kreitchmann; Alice Stek; Brookie M Best; Edmund Capparelli; JiaJia Wang; David Shapiro; Nahida Chakhtoura; Mark Mirochnick; Ahizechukwu C Eke
Journal:  Contraception       Date:  2021-08-15       Impact factor: 3.375

  1 in total