Literature DB >> 19591119

Development and validation of UPLC-MS/MS method for simultaneous determination of gestodene and ethinyl estradiol in rat plasma.

Zhili Xiong1, Xiaohong Sun, Taoguang Huo, Ning Li, Yan Zheng, Yi Sun.   

Abstract

A selective and sensitive ultra-performance liquid chromatography method with tandem mass spectrometric detection for simultaneous determination of gestodene (GES) and ethinyl estradiol (EE) in rat plasma was developed and validated. GES, EE and the internal standard, norgestrel, were extracted with ethyl acetate, derivatized (EE only) with dansyl chloride and then back-extracted into diethyl ether-hexane (2:1, v/v). The separation was performed on an ACQUITY UPLC BEH C(18) column with gradient elution using mobile phase consisting of acetonitrile and water (both containing 0.1% formic acid). The detection was carried out by means of electrospray ionization (ESI) mass spectrometry in positive ion mode with multiple-reaction monitoring. Calibration curves of GES and EE were linear (r(2) >or= 0.99) over the concentration ranges 1.59-159 and 0.196-78.4 ng/mL, respectively. The intra- and inter-day precisions were not more than 6.9 and 12.9% for GES and 10.6 and 9.0% for EE, and the accuracies were -2.5-8.0% for GES, and -7.2-0.19% for EE, respectively. The method herein described was superior to previous methods and was applicable to the pharmacokinetic study of GES and EE in rats. (c) 2009 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19591119     DOI: 10.1002/bmc.1265

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  3 in total

1.  Simultaneous determination of etonogestrel and ethinyl estradiol in human plasma by UPLC-MS/MS and its pharmacokinetic study.

Authors:  Sneha G Nair; Daxesh P Patel; Frank J Gonzalez; Bhargav M Patel; Puran Singhal; Darshan V Chaudhary
Journal:  Biomed Chromatogr       Date:  2018-01-19       Impact factor: 1.902

2.  Comparison of life-stage-dependent internal dosimetry for bisphenol A, ethinyl estradiol, a reference estrogen, and endogenous estradiol to test an estrogenic mode of action in Sprague Dawley rats.

Authors:  Mona I Churchwell; Luísa Camacho; Michelle M Vanlandingham; Nathan C Twaddle; Estatira Sepehr; K Barry Delclos; Jeffrey W Fisher; Daniel R Doerge
Journal:  Toxicol Sci       Date:  2014-02-04       Impact factor: 4.849

3.  High-sensitivity simultaneous liquid chromatography-tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma.

Authors:  Abhishek Gandhi; Swati Guttikar; Priti Trivedi
Journal:  J Pharm Anal       Date:  2015-02-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.