Literature DB >> 15340965

Development and validation of a high-sensitivity liquid chromatography/tandem mass spectrometry (LC/MS/MS) method with chemical derivatization for the determination of ethinyl estradiol in human plasma.

Wilson Z Shou1, Xiangyu Jiang, Weng Naidong.   

Abstract

An ultra-sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the analysis of oral contraceptive ethinyl estradiol (EE) was developed and validated over the curve range of 2.5-500 pg/mL using 1 mL of human plasma sample. Ethinyl estradiol and the internal standard, ethinyl estradiol tetra-deuterated (EE-d4), were extracted from the plasma matrix with methyl t-butyl ether, derivatized with dansyl chloride and then back-extracted into hexane. The hexane phase was evaporated to dryness, reconstituted and injected onto the LC/MS/MS system. The chromatographic separation was achieved on a Luna C(18) column (50 x 2 mm, 5 micro m) with an isocratic mobile phase of 20:80 (v/v) water:acetonitrile with 1% formic acid. The offline derivatization procedure introduced the easily ionizable tertiary amine function group to EE. This greatly improved analyte sensitivity in electrospray ionization and enabled us to achieve the desired lower limit of quantitation at 2.5 pg/mL. This high sensitivity method can be used for therapeutic drug monitoring or supporting bio-equivalence and drug-drug interaction studies in human subjects.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15340965     DOI: 10.1002/bmc.329

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  3 in total

1.  Simultaneous determination of etonogestrel and ethinyl estradiol in human plasma by UPLC-MS/MS and its pharmacokinetic study.

Authors:  Sneha G Nair; Daxesh P Patel; Frank J Gonzalez; Bhargav M Patel; Puran Singhal; Darshan V Chaudhary
Journal:  Biomed Chromatogr       Date:  2018-01-19       Impact factor: 1.902

2.  Analysis of steroidal estrogens as pyridine-3-sulfonyl derivatives by liquid chromatography electrospray tandem mass spectrometry.

Authors:  Li Xu; David C Spink
Journal:  Anal Biochem       Date:  2007-11-28       Impact factor: 3.365

3.  High-sensitivity simultaneous liquid chromatography-tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma.

Authors:  Abhishek Gandhi; Swati Guttikar; Priti Trivedi
Journal:  J Pharm Anal       Date:  2015-02-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.