BACKGROUND: The aim of this study is to evaluate the accuracy of bone cuts and the resultant alignment, using the MyKnee patient specific cutting blocks. METHODS: We retrospectively reviewed 132 patients undergoing primary TKR for osteoarthritis by one single surgeon. The operative time, the preoperative Hip-Knee-Ankle (HKA) axis based on the CT-scan, the postoperative HKA axis based on long axis standing x-rays, the planned and the actual size of the femoral and the tibial components, and the number of the recuts which has been made intraoperative were measured. RESULTS: The average preoperative HKA axis was 177.50 (range 163.50 to 1940), whereas the average postoperative HKA axis was 179.40 (range 177.10 to 182.70). No outliers were reported in the study (0%). Intraoperatively, 4 femoral components (3.03%), and 7 tibial components (5.30%) applied to the patients were different than the planned size. There was no need of recuts in any of our cases intraoperatively. CONCLUSION: The MyKnee system evaluated in this study was shown to be remarkable reliable in the coronal plane alignment, and the prediction of the component size. However, further studies are needed to determine whether there are any clinically important improvements in outcomes or patient satisfaction when using patient-specific cutting blocks for TKA.
BACKGROUND: The aim of this study is to evaluate the accuracy of bone cuts and the resultant alignment, using the MyKnee patient specific cutting blocks. METHODS: We retrospectively reviewed 132 patients undergoing primary TKR for osteoarthritis by one single surgeon. The operative time, the preoperative Hip-Knee-Ankle (HKA) axis based on the CT-scan, the postoperative HKA axis based on long axis standing x-rays, the planned and the actual size of the femoral and the tibial components, and the number of the recuts which has been made intraoperative were measured. RESULTS: The average preoperative HKA axis was 177.50 (range 163.50 to 1940), whereas the average postoperative HKA axis was 179.40 (range 177.10 to 182.70). No outliers were reported in the study (0%). Intraoperatively, 4 femoral components (3.03%), and 7 tibial components (5.30%) applied to the patients were different than the planned size. There was no need of recuts in any of our cases intraoperatively. CONCLUSION: The MyKnee system evaluated in this study was shown to be remarkable reliable in the coronal plane alignment, and the prediction of the component size. However, further studies are needed to determine whether there are any clinically important improvements in outcomes or patient satisfaction when using patient-specific cutting blocks for TKA.
Entities:
Keywords:
CT scan; HKA ankle; Knee alignment; Patient specific instruments; Total knee arthroplasty
Authors: Vincent Y Ng; Jeffrey H DeClaire; Keith R Berend; Bethany C Gulick; Adolph V Lombardi Journal: Clin Orthop Relat Res Date: 2012-01 Impact factor: 4.176
Authors: Werner Anderl; Leo Pauzenberger; Roman Kölblinger; Gabriele Kiesselbach; Georg Brandl; Brenda Laky; Bernhard Kriegleder; Philipp Heuberer; Eva Schwameis Journal: Knee Surg Sports Traumatol Arthrosc Date: 2014-10-19 Impact factor: 4.342
Authors: Jörg Arnholdt; Yama Kamawal; Konstantin Horas; Boris M Holzapfel; Fabian Gilbert; Axel Ripp; Maximilian Rudert; Andre F Steinert Journal: BMC Musculoskelet Disord Date: 2020-10-22 Impact factor: 2.362