Literature DB >> 29184764

Dual energy CT angiography in peripheral arterial stents: optimal scanning protocols with regard to image quality and radiation dose.

Abdulrahman Almutairi1,2, Zakariya Al Safran2, Saif A AlZaabi2, Zhonghua Sun1.   

Abstract

BACKGROUND: To determine the optimal scanning protocols of dual energy computed tomography angiography (DECTA) in terms of radiation dose and image quality assessment at different keV levels, and compare it with conventional computed tomography angiography (CTA) in patients treated with peripheral arterial stents.
METHODS: Twenty-nine patients with previous stent placement in peripheral arteries were evaluated with DECTA. Images were reconstructed with virtual monochromatic spectral imaging (VMS) at 65, 68, 70 and 72 keV and adaptive statistical iterative reconstruction (ASIR) at 50% compared with CTA. Image quality comprising image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed, and radiation dose was compared. Effects of different type of peripheral arterial stents on image quality were also evaluated. Fifty-six uniquely identified stents that were located in common iliac arteries (CIA), external iliac arteries (EIA) and superficial femoral arteries (SFA) were evaluated.
RESULTS: Within subjects, the results showed that DECTA images (VMS) had less noise than the CTA images for CIA, EIA and SFA stents, with the lowest noise at 72 keV. Also, the VMS images had greater SNR than the CTA images for the EIA stents (P<0.05); and the VMS images had greater CNR than the CTA images for CIA, EIA, and SFA stents (P<0.001). Also, on CT attenuation, VMS continued to outperform CTA, but to a lesser extent. Between subjects, average VMS noise varied significantly with the type of the stent used (P=0.025) for CIA stents. Radiation dose was highly significant between DECTA and conventional CTA scans (6.98 vs. 7.40 mSv, P=0.047).
CONCLUSIONS: We conclude that an optimal scanning protocol consisting of 72 keV and 50% ASIR leads to better image quality for DECTA in peripheral arterial stenting when compared to conventional CTA.

Entities:  

Keywords:  Dual-energy CT; image quality; peripheral arterial stents; radiation dose

Year:  2017        PMID: 29184764      PMCID: PMC5682398          DOI: 10.21037/qims.2017.10.07

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  22 in total

1.  Stent appearance at contrast-enhanced MR angiography: in vitro examination with 14 stents.

Authors:  M Lenhart; M Völk; C Manke; W R Nitz; M Strotzer; S Feuerbach; J Link
Journal:  Radiology       Date:  2000-10       Impact factor: 11.105

Review 2.  Dual-Energy Spectral CT: Various Clinical Vascular Applications.

Authors:  Haruhiko Machida; Isao Tanaka; Rika Fukui; Yun Shen; Takuya Ishikawa; Etsuko Tate; Eiko Ueno
Journal:  Radiographics       Date:  2016 Jul-Aug       Impact factor: 5.333

3.  Dual energy CT of peripheral arteries: effect of automatic bone and plaque removal on image quality and grading of stenoses.

Authors:  B C Meyer; T Werncke; W Hopfenmüller; H J Raatschen; K-J Wolf; T Albrecht
Journal:  Eur J Radiol       Date:  2008-10-28       Impact factor: 3.528

4.  Dual energy versus single energy MDCT: measurement of radiation dose using adult abdominal imaging protocols.

Authors:  Lisa M Ho; Terry T Yoshizumi; Lynne M Hurwitz; Rendon C Nelson; Daniele Marin; Greta Toncheva; Sebastian T Schindera
Journal:  Acad Radiol       Date:  2009-07-10       Impact factor: 3.173

5.  First experience with single-source, dual-energy CCTA for monochromatic stent imaging.

Authors:  Julia Stehli; Tobias A Fuchs; Adrian Singer; Sacha Bull; Olivier F Clerc; Mathias Possner; Oliver Gaemperli; Ronny R Buechel; Philipp A Kaufmann
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2014-12-18       Impact factor: 6.875

6.  Initial experience with single-source dual-energy CT abdominal angiography and comparison with single-energy CT angiography: image quality, enhancement, diagnosis and radiation dose.

Authors:  Daniella F Pinho; Naveen M Kulkarni; Arun Krishnaraj; Sanjeeva P Kalva; Dushyant V Sahani
Journal:  Eur Radiol       Date:  2012-08-25       Impact factor: 5.315

7.  Estimates of effective dose for CT scans of the lower extremities.

Authors:  Natalia Saltybaeva; Mary Ellen Jafari; Martin Hupfer; Willi A Kalender
Journal:  Radiology       Date:  2014-06-16       Impact factor: 11.105

8.  Placement of hemoparin-coated stents in the iliac arteries: early experience and midterm results in 28 patients.

Authors:  Peter I Kalmar; Rupert H Portugaller; Peter Schedlbauer; Dennis Bohlsen; Hannes A Deutschmann
Journal:  Eur J Radiol       Date:  2014-04-18       Impact factor: 3.528

9.  Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging.

Authors:  Sonja Sudarski; Paul Apfaltrer; John W Nance; David Schneider; Mathias Meyer; Stefan O Schoenberg; Christian Fink; Thomas Henzler
Journal:  Eur J Radiol       Date:  2013-06-10       Impact factor: 3.528

10.  Optimal Scanning Protocols for Dual-Energy CT Angiography in Peripheral Arterial Stents: An in Vitro Phantom Study.

Authors:  Abdulrahman Almutairi; Zhonghua Sun; Zakariya Al Safran; Abduljaleel Poovathumkadavi; Suha Albader; Husam Ifdailat
Journal:  Int J Mol Sci       Date:  2015-05-20       Impact factor: 5.923

View more
  4 in total

1.  3D printing in medicine: current applications and future directions.

Authors:  Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2018-12

2.  Positive visualization of MR-compatible nitinol stent using a susceptibility-based imaging technique.

Authors:  Caiyun Shi; Guoxi Xie; Dong Liang; Haifeng Wang; Yi Huang; Yanan Ren; Yong Xue; Hanwei Chen; Shi Su; Xin Liu
Journal:  Quant Imaging Med Surg       Date:  2019-03

3.  Split-filter dual-energy CT pulmonary angiography for the diagnosis of acute pulmonary embolism: a study on image quality and radiation dose.

Authors:  Bernhard Petritsch; Pauline Pannenbecker; Andreas M Weng; Jan-Peter Grunz; Simon Veldhoen; Thorsten A Bley; Aleksander Kosmala
Journal:  Quant Imaging Med Surg       Date:  2021-05

4.  Mixed reality models based on low-dose computed tomography technology in nephron-sparing surgery are better than models based on normal-dose computed tomography.

Authors:  Guan Li; Zhiqiang Cao; Jinbao Wang; Xin Zhang; Longjiang Zhang; Jie Dong; Guangming Lu
Journal:  Quant Imaging Med Surg       Date:  2021-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.