| Literature DB >> 29178898 |
L Castro1, S Pecha2, M Linder2, J Vogler3, N Gosau3, C Meyer3, S Willems3, H Reichenspurner2, S Hakmi2.
Abstract
BACKGROUND: The approach to treat device infection in patients with implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) is a challenging procedure. Optimal treatment is complete extraction of the infected device. To protect these patients from sudden cardiac arrest while waiting for reimplantation and to avoid recurrent infection, a wearable cardioverter defibrillator (WCD) seems to be a valuable solution. Therefore, we investigated the management and outcome of patients with ICD or CRT-D infections using the WCD as a bridge to re-implantation after lead extraction procedures.Entities:
Keywords: CIED-infection; ICD infection; Lead/ device extraction; Sudden cardiac arrest; Ventricular tachycardia; Wearable cardioverter defibrillator
Mesh:
Substances:
Year: 2017 PMID: 29178898 PMCID: PMC5702096 DOI: 10.1186/s13019-017-0669-2
Source DB: PubMed Journal: J Cardiothorac Surg ISSN: 1749-8090 Impact factor: 1.637
Baseline and clinical characteristics
| Patients |
(
|
|---|---|
| Demographics | |
| Age, years | 65 ± 8 |
| Male gender, n (%) | 16 (76.2) |
| Medical history | |
| Renal failure, n (%) | 7 (33.3) |
| Diabetes mellitus, n (%) | 9 (42.85) |
| Coronary artery disease, n (%) | 11 (52.4) |
| Symptoms | |
| Pocket infection, n (%) | 14 (66.7) |
| Systemic infection, n (%) | 7 (33.3) |
| Laboratory | |
| Leucocytes billion/l | 8.7 ± 2.2 |
| C-reactive protein mg/l | 66.0 ± 61 |
Continuous variables are expressed as mean ± standard deviation and categorical are expressed by values and percentages
Device characteristics
| Devices |
(
|
|---|---|
| Indication for implantation | |
| Ischemic cardiomyopathy, n (%) | 7 (33.3) |
| Non-ischemic cardiomyopathy, n (%) | 14 (66.7) |
| Long QT syndrome, n (%) | 1 (4.8) |
| ARVC, n (%) | 2 (9.5) |
| Secondary prophylaxis, n (%) | 11 (52.4) |
| Explanted | |
| VVI-ICD, n (%) | 5 (23.8) |
| DDD-ICD, n (%) | 6 (28.6) |
| CRT-D, n (%) | 10 (47.6) |
| Reimplanted | |
| VVI-ICD, n (%) | 6 (28.6) |
| DDD-ICD, n (%) | 3 (14.3) |
| CRT-D, n (%) | 9 (42.8) |
| S-ICD, n (%) | 3 (14.3) |
| Time to re-implantation, days | 51.6 ± 16.9 |
ARVC Arrhythmogenic right ventricular cardiomyopathy
Continuous variables are expressed as mean ± standard deviation and categorical are expressed by values and percentages
Fig. 1Successful wearable cardioverter defibrillator shock (150 J)