Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators: results of a large prospective study.

Didier Klug1, Mamadou Balde, Dominique Pavin, Françoise Hidden-Lucet, Jacques Clementy, Nicolas Sadoul, Jean Luc Rey, Gilles Lande, Arnaud Lazarus, Jacques Victor, Claude Barnay, Bruno Grandbastien, Salem Kacet.   

Abstract

BACKGROUND: The Prospective Evaluation of Pacemaker Lead Endocarditis study is a multicenter, prospective survey of the incidence and risk factors of infectious complications after implantation of pacemakers and cardioverter-defibrillators. METHODS AND
RESULTS: Between January 1, 2000, and December 31, 2000, 6319 consecutive recipients of implantable systems were enrolled at 44 medical centers and followed up for 12 months. All infectious complications were recorded, and their occurrence was related to the baseline demographic, clinical, and procedural characteristics. Among 5866 pacing systems, 3789 included 2 and 117 had >2 leads; among 453 implantable cardioverter-defibrillators, 178 were dual-lead systems. A total of 4461 de novo implantations occurred and 1858 pulse generator or lead replacements. Reinterventions were performed before hospital discharge in 101 patients. Single- and multiple-variable logistic regression analyses were performed to identify risk factors; adjusted odds ratios (aORs) and 95% confidence intervals (CIs) were calculated. At 12 months, device-related infections were reported in 42 patients (0.68%; 95% CI, 0.47 to 0.89). The occurrence of infection was positively correlated with fever within 24 hours before the implantation procedure (aOR, 5.83; 95% CI, 2.00 to 16.98), use of temporary pacing before the implantation procedure (aOR, 2.46; 95% CI, 1.09 to 5.13), and early reinterventions (aOR, 15.04; 95% CI, 6.7 to 33.73). Implantation of a new system (aOR, 0.46; 95% CI, 0.24 to 0.87) and antibiotic prophylaxis (aOR, 0.4; 95% CI, 0.18 to 0.86) were negatively correlated with risk of infection.
CONCLUSIONS: This study identified several factors of risk of device infection and confirmed the efficacy of antibiotic prophylaxis in recipients of new or replacement pacemakers or implantable cardioverter-defibrillators.

Entities:  

Mesh:

Year:  2007        PMID: 17724263     DOI: 10.1161/CIRCULATIONAHA.106.678664

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  132 in total

Review 1.  Determinants of intracellular pH in the erythrocyte.

Authors:  J Warth; J F Desforges
Journal:  Br J Haematol       Date:  1975-03       Impact factor: 6.998

Review 2.  Current trends in the management of cardiac implantable electronic device (CIED) infections.

Authors:  Emanuele Durante-Mangoni; Irene Mattucci; Federica Agrusta; Marie-Françoise Tripodi; Riccardo Utili
Journal:  Intern Emerg Med       Date:  2012-06-29       Impact factor: 3.397

3.  [Scientific results of the pacemaker register: possibilities and limits].

Authors:  U K H Wiegand; B Lemke; B Nowak
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2010-09

4.  The prevalence of methicillin resistant organisms among pacemaker and defibrillator implant recipients.

Authors:  David J Rodriguez; Aisha Afzal; Rudolph Evonich; David E Haines
Journal:  Am J Cardiovasc Dis       Date:  2012-05-15

Review 5.  Considerations for cardiac device lead extraction.

Authors:  Oussama Wazni; Bruce L Wilkoff
Journal:  Nat Rev Cardiol       Date:  2016-01-29       Impact factor: 32.419

6.  The Promise of Leadless Pacing: Based on Presentations at Nanostim Sponsored Symposium Held at the European Society of Cardiology Congress 2013, Amsterdam, The Netherlands, 2 September 2013.

Authors:  Katrina Mountfort; Reinoud Knops; Johannes Sperzel; Petr Neuzil
Journal:  Arrhythm Electrophysiol Rev       Date:  2014-05-30

7.  A meta-analysis of antibacterial envelope use in prevention of cardiovascular implantable electronic device infection.

Authors:  Sajid Ali; Yousuf Kanjwal; Steven R Bruhl; Mohammed Alo; Mohammed Taleb; Syed S Ali; Ameer Kabour; Owais Khawaja
Journal:  Ther Adv Infect Dis       Date:  2017-05-01

8.  New Insights into Predictors of Cardiac Implantable Electronic Device Infection.

Authors:  Hossein Sadeghi; Abolfath Alizadehdiz; Amirfarjam Fazelifar; Zahra Emkanjoo; Majid Haghjoo
Journal:  Tex Heart Inst J       Date:  2018-06-01

9.  Use of an antibacterial envelope is associated with reduced cardiac implantable electronic device infections in high-risk patients.

Authors:  Matthew J Kolek; William F Dresen; Quinn S Wells; Christopher R Ellis
Journal:  Pacing Clin Electrophysiol       Date:  2012-12-17       Impact factor: 1.976

10.  ICD Implantation in Patients With Ischemic Left Ventricular Dysfunction.

Authors:  Jaydutt B Patel; Bruce A Koplan
Journal:  Curr Treat Options Cardiovasc Med       Date:  2009-02
View more