Literature DB >> 23426553

Transcutaneous lead implantation connected to an externalized pacemaker in patients with implantable cardiac defibrillator/pacemaker infection and pacemaker dependency.

Simon Pecha1, Muhammed Ali Aydin, Yalin Yildirim, Björn Sill, Beate Reiter, Iris Wilke, Hermann Reichenspurner, Hendrik Treede.   

Abstract

AIMS: Systemic cardiac implantable electronic device (CIED) infection is a serious complication, especially in patients with pacemaker (PM) dependency. In those patients after infectious device removal temporary pacing is necessary, to obtain adequate haemodynamics. In this study, a new therapy option with temporary pacing by ipsilateral implantation of a new active-fixation right ventricular (RV)-lead was evaluated. METHODS AND
RESULTS: Between September 2009 and November 2011, infectious lead removal was performed in 17 patients with systemic CIED infection. Temporary pacing was achieved by simultaneous implantation of a new active-fixation RV-lead, which then was connected extracorporally to the old CIED device. Antibiotic therapy was initiated. When laboratory infection parameters were in normal range and blood culture samples showed negative results, new CIED was implanted on contralateral side and temporary RV-lead was removed. Mean patients' age was 71.3 ± 9.1 years. Mean C-reactive protein values were 79.3 mg/dL, and mean leucocytes counts were 12.6 × 10(3). After lead extraction, temporary pacing was necessary in all patients due to severe bradycardia. Mean duration of temporary pacing was 12.7 (6-24) days. No major procedure-related peri- or post-operative adverse events occurred. Mean time of hospitalization was 20.8 (10-48) days. Mean follow-up time was 21.1 months (12-36), showing survival rate of 100% and freedom from reinfection in all patients.
CONCLUSION: Ipsilateral implantation of a temporary active-fixation RV-lead connected to an externalized PM and pursued antibiotic therapy seems to be a good option for patients with CIED infection and PM dependency, showing no temporary pacing-related complications and no reinfection after mean follow-up time of 21.1 months.

Entities:  

Keywords:  CIED infection; Pacemaker; Temporary pacing

Mesh:

Substances:

Year:  2013        PMID: 23426553     DOI: 10.1093/europace/eut031

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  7 in total

1.  The Diagnosis and Treatment of Pacemaker-Associated Infection.

Authors:  Michael Döring; Sergio Richter; Gerhard Hindricks
Journal:  Dtsch Arztebl Int       Date:  2018-06-29       Impact factor: 5.594

2.  Initial experience of pacemaker and implantable cardioverter defibrillator lead extraction with the new GlideLight 80 Hz laser sheaths.

Authors:  Samer Hakmi; Simon Pecha; Björn Sill; Beate Reiter; Stephan Willems; Muhammet Ali Aydin; Yalin Yildirim; Hermann Reichenspurner; Hendrik Treede
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-09-30

3.  Safety and efficacy of transvenous lead extraction of very old leads.

Authors:  Simon Pecha; Tibor Ziegelhoeffer; Yalin Yildirim; Yeong-Hoon Choi; Stephan Willems; Hermann Reichenspurner; Heiko Burger; Samer Hakmi
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-04-08

4.  The wearable cardioverter defibrillator as a bridge to reimplantation in patients with ICD or CRT-D-related infections.

Authors:  L Castro; S Pecha; M Linder; J Vogler; N Gosau; C Meyer; S Willems; H Reichenspurner; S Hakmi
Journal:  J Cardiothorac Surg       Date:  2017-11-25       Impact factor: 1.637

5.  Comparison of Leadless Pacing and Temporary Externalized Pacing Following Cardiac Implanted Device Extraction.

Authors:  Holly Gonzales; Travis D Richardson; Jay A Montgomery; George H Crossley; Christopher R Ellis
Journal:  J Innov Card Rhythm Manag       Date:  2019-12-15

6.  European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections-endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS).

Authors:  Carina Blomström-Lundqvist; Vassil Traykov; Paola Anna Erba; Haran Burri; Jens Cosedis Nielsen; Maria Grazia Bongiorni; Jeanne Poole; Giuseppe Boriani; Roberto Costa; Jean-Claude Deharo; Laurence M Epstein; Laszlo Saghy; Ulrika Snygg-Martin; Christoph Starck; Carlo Tascini; Neil Strathmore
Journal:  Europace       Date:  2020-04-01       Impact factor: 5.214

Review 7.  A Review of Temporary Permanent Pacemakers and a Comparison with Conventional Temporary Pacemakers.

Authors:  Keith Suarez; Javier E Banchs
Journal:  J Innov Card Rhythm Manag       Date:  2019-05-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.