Literature DB >> 29098167

Mesh-to-raster region-of-interest-based nonrigid registration of multimodal images.

Rosalia Tatano1, Benjamin Berkels1, Thomas M Deserno2.   

Abstract

Region of interest (RoI) alignment in medical images plays a crucial role in diagnostics, procedure planning, treatment, and follow-up. Frequently, a model is represented as triangulated mesh while the patient data is provided from computed axial tomography scanners as pixel or voxel data. Previously, we presented a 2-D method for curve-to-pixel registration. This paper contributes (i) a general mesh-to-raster framework to register RoIs in multimodal images; (ii) a 3-D surface-to-voxel application, and (iii) a comprehensive quantitative evaluation in 2-D using ground truth (GT) provided by the simultaneous truth and performance level estimation (STAPLE) method. The registration is formulated as a minimization problem, where the objective consists of a data term, which involves the signed distance function of the RoI from the reference image and a higher order elastic regularizer for the deformation. The evaluation is based on quantitative light-induced fluoroscopy (QLF) and digital photography (DP) of decalcified teeth. STAPLE is computed on 150 image pairs from 32 subjects, each showing one corresponding tooth in both modalities. The RoI in each image is manually marked by three experts (900 curves in total). In the QLF-DP setting, our approach significantly outperforms the mutual information-based registration algorithm implemented with the Insight Segmentation and Registration Toolkit and Elastix.

Entities:  

Keywords:  RoI alignment; curve-to-pixel registration; evaluation; simultaneous truth and performance level estimation, virtual physiological human; surface-to-voxel registration

Year:  2017        PMID: 29098167      PMCID: PMC5658683          DOI: 10.1117/1.JMI.4.4.044002

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  18 in total

Review 1.  Medical image registration: a review.

Authors:  Francisco P M Oliveira; João Manuel R S Tavares
Journal:  Comput Methods Biomech Biomed Engin       Date:  2012-03-22       Impact factor: 1.763

2.  Deformable image registration of CT images for automatic contour propagation in radiation therapy.

Authors:  Qian Wu; Ruifen Cao; Xi Pei; Jing Jia; Liqin Hu
Journal:  Biomed Mater Eng       Date:  2015       Impact factor: 1.300

3.  Dental biometrics: alignment and matching of dental radiographs.

Authors:  Hong Chen; Anil K Jain
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2005-08       Impact factor: 6.226

4.  elastix: a toolbox for intensity-based medical image registration.

Authors:  Stefan Klein; Marius Staring; Keelin Murphy; Max A Viergever; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2009-11-17       Impact factor: 10.048

5.  Deformable medical image registration of pleural cavity for photodynamic therapy by using finite-element based method.

Authors:  Rozhin Penjweini; Michele M Kim; Andrea Dimofte; Jarod C Finlay; Timothy C Zhu
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-07

6.  Evaluation of registration methods on thoracic CT: the EMPIRE10 challenge.

Authors:  Keelin Murphy; Bram van Ginneken; Joseph M Reinhardt; Sven Kabus; Kai Ding; Xiang Deng; Kunlin Cao; Kaifang Du; Gary E Christensen; Vincent Garcia; Tom Vercauteren; Nicholas Ayache; Olivier Commowick; Grégoire Malandain; Ben Glocker; Nikos Paragios; Nassir Navab; Vladlena Gorbunova; Jon Sporring; Marleen de Bruijne; Xiao Han; Mattias P Heinrich; Julia A Schnabel; Mark Jenkinson; Cristian Lorenz; Marc Modat; Jamie R McClelland; Sébastien Ourselin; Sascha E A Muenzing; Max A Viergever; Dante De Nigris; D Louis Collins; Tal Arbel; Marta Peroni; Rui Li; Gregory C Sharp; Alexander Schmidt-Richberg; Jan Ehrhardt; René Werner; Dirk Smeets; Dirk Loeckx; Gang Song; Nicholas Tustison; Brian Avants; James C Gee; Marius Staring; Stefan Klein; Berend C Stoel; Martin Urschler; Manuel Werlberger; Jef Vandemeulebroucke; Simon Rit; David Sarrut; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2011-05-31       Impact factor: 10.048

Review 7.  Survey of Non-Rigid Registration Tools in Medicine.

Authors:  András P Keszei; Benjamin Berkels; Thomas M Deserno
Journal:  J Digit Imaging       Date:  2017-02       Impact factor: 4.056

8.  A contour-guided deformable image registration algorithm for adaptive radiotherapy.

Authors:  Xuejun Gu; Bin Dong; Jing Wang; John Yordy; Loren Mell; Xun Jia; Steve B Jiang
Journal:  Phys Med Biol       Date:  2013-02-27       Impact factor: 3.609

9.  Co-registration of intra-operative brain surface photographs and pre-operative MR images.

Authors:  Benjamin Berkels; Ivan Cabrilo; Sven Haller; Martin Rumpf; Karl Schaller
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-01-30       Impact factor: 2.924

Review 10.  The Virtual Physiological Human: Ten Years After.

Authors:  Marco Viceconti; Peter Hunter
Journal:  Annu Rev Biomed Eng       Date:  2016-07-11       Impact factor: 9.590

View more
  1 in total

1.  Spatial agreement of demineralized areas in quantitative light-induced fluorescence images and digital photographs.

Authors:  Rosalia Tatano; Benjamin Berkels; Eva E Ehrlich; Thomas M Deserno; Ulrike B Fritz
Journal:  Dentomaxillofac Radiol       Date:  2018-06-15       Impact factor: 2.419

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.