Literature DB >> 27053826

Deformable medical image registration of pleural cavity for photodynamic therapy by using finite-element based method.

Rozhin Penjweini1, Michele M Kim2, Andrea Dimofte1, Jarod C Finlay1, Timothy C Zhu1.   

Abstract

When the pleural cavity is opened during the surgery portion of pleural photodynamic therapy (PDT) of malignant mesothelioma, the pleural volume will deform. This impacts the delivered dose when using highly conformal treatment techniques. To track the anatomical changes and contour the lung and chest cavity, an infrared camera-based navigation system (NDI) is used during PDT. In the same patient, a series of computed tomography (CT) scans of the lungs are also acquired before the surgery. The reconstructed three-dimensional contours from both NDI and CTs are imported into COMSOL Multiphysics software, where a finite element-based (FEM) deformable image registration is obtained. The CT contour is registered to the corresponding NDI contour by overlapping the center of masses and aligning their orientations. The NDI contour is considered as the reference contour, and the CT contour is used as the target one, which will be deformed. Deformed Geometry model is applied in COMSOL to obtain a deformed target contour. The distortion of the volume at X, Y and Z is mapped to illustrate the transformation of the target contour. The initial assessment shows that FEM-based image deformable registration can fuse images acquired by different modalities. It provides insights into the deformation of anatomical structures along X, Y and Z-axes. The deformed contour has good matches to the reference contour after the dynamic matching process. The resulting three-dimensional deformation map can be used to obtain the locations of other critical anatomic structures, e.g., heart, during surgery.

Entities:  

Keywords:  CT; NDI; PDT; finite element-based method; image deformable registration; lung and chest cavity; mesothelioma

Year:  2016        PMID: 27053826      PMCID: PMC4819259          DOI: 10.1117/12.2211110

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  11 in total

1.  Effects of age on elastic moduli of human lungs.

Authors:  S J Lai-Fook; R E Hyatt
Journal:  J Appl Physiol (1985)       Date:  2000-07

2.  Multiscale deformable registration of noisy medical images.

Authors:  Dana Paquin; Doron Levy; Lei Xing
Journal:  Math Biosci Eng       Date:  2008-01       Impact factor: 2.080

Review 3.  Deformable medical image registration: a survey.

Authors:  Aristeidis Sotiras; Christos Davatzikos; Nikos Paragios
Journal:  IEEE Trans Med Imaging       Date:  2013-05-31       Impact factor: 10.048

4.  Real-time treatment light dose guidance of Pleural PDT: an update.

Authors:  Timothy C Zhu; Michele M Kim; Steve L Jacques; Rozhin Penjweini; Andreea Dimofte; Jarod C Finlay; Charles B Simone; Keith A Cengel; Joseph Friedberg
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-02

5.  Explicit dosimetry for 2-(1-hexyloxyethyl)-2-devinyl pyropheophorbide-a-mediated photodynamic therapy: macroscopic singlet oxygen modeling.

Authors:  Rozhin Penjweini; Baochang Liu; Michele M Kim; Timothy C Zhu
Journal:  J Biomed Opt       Date:  2015       Impact factor: 3.170

6.  Modifying excitation light dose of novel photosensitizer PVP-Hypericin for photodynamic diagnosis and therapy.

Authors:  Rozhin Penjweini; Hans G Loew; Maria Eisenbauer; Karl W Kratky
Journal:  J Photochem Photobiol B       Date:  2013-01-10       Impact factor: 6.252

7.  Reducing uncertainties in volumetric image based deformable organ registration.

Authors:  J Liang; D Yan
Journal:  Med Phys       Date:  2003-08       Impact factor: 4.071

8.  Toward in vivo lung's tissue incompressibility characterization for tumor motion modeling in radiation therapy.

Authors:  Zahra Shirzadi; Ali Sadeghi-Naini; Abbas Samani
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

9.  A finite element method to correct deformable image registration errors in low-contrast regions.

Authors:  Hualiang Zhong; Jinkoo Kim; Haisen Li; Teamour Nurushev; Benjamin Movsas; Indrin J Chetty
Journal:  Phys Med Biol       Date:  2012-05-11       Impact factor: 3.609

10.  Micro-mechanical characterization of lung tissue using atomic force microscopy.

Authors:  Fei Liu; Daniel J Tschumperlin
Journal:  J Vis Exp       Date:  2011-08-28       Impact factor: 1.355

View more
  2 in total

1.  Three-dimensional finite-element based deformable image registration for evaluation of pleural cavity irradiation during photodynamic therapy.

Authors:  Rozhin Penjweini; Michele M Kim; Timothy C Zhu
Journal:  Med Phys       Date:  2017-05-24       Impact factor: 4.071

2.  Mesh-to-raster region-of-interest-based nonrigid registration of multimodal images.

Authors:  Rosalia Tatano; Benjamin Berkels; Thomas M Deserno
Journal:  J Med Imaging (Bellingham)       Date:  2017-10-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.