Literature DB >> 29071823

Effect of Accreditation on the Accuracy of Diagnostic Hematologic Tests: Standard Deviation Index Analysis.

Young Ahn Yoon1, Mi Ae Jang2, Ji Sung Lee3, Won Ki Min4, Kye Chul Kwon5, Yong Wha Lee6, You Kyoung Lee7.   

Abstract

Entities:  

Mesh:

Year:  2018        PMID: 29071823      PMCID: PMC5700151          DOI: 10.3343/alm.2018.38.1.67

Source DB:  PubMed          Journal:  Ann Lab Med        ISSN: 2234-3806            Impact factor:   3.464


× No keyword cloud information.
Dear Editor, Thorough quality management is paramount because diagnostic tests play an important role in medical decisions and can involve a complex, multistep process, from sampling to reporting the test results. In general, the reliability of a diagnostic test is based on two factors: diagnostic product standardization and practice standardization. While diagnostic product standardization is established on a legal basis with administrative assistance, practice standardization is less well established and can, to a large extent, depend on the private sector. In Korea, this private sector involvement is mediated through the Korean Laboratory Accreditation Program (KLAP). KLAP was established in 1999 and instituted by Korean Society for Laboratory Medicine (KSLM) [1]. KLAP conducts document screening and on-site inspections to assess test results and compliance with practice standardization. The Korean external quality assessment scheme (KEQAS) is a proficiency testing program run by the Korean Association of Quality Assurance for Clinical Laboratory [2]. KEQAS distributes the same material to all participating laboratories and statistically analyzes the results of the measurements. This permits the analytical accuracy of the test results of individual laboratories to be monitored and objectively measured. Laboratories that participate only in the KEQAS are designated as basically-standardized laboratories (BSL). A highly-standardized laboratory (HSL) is a laboratory that participates simultaneously in KEQAS and KLAP and obtains a certificate of accreditation. Recently, we reported the results of an accreditation analysis of clinical chemistry tests in clinical laboratories [3]. We concluded that practice standardization is strongly associated with the accuracy of clinical chemistry test results. Here, we extended the findings by analyzing the impact of standardization on diagnostic hematology test results. Five items, Hb, Hct, red blood cell (RBC), white blood cell (WBC), and platelet count, were analyzed. The analyses involved results obtained from 30,616 samples over a 9-year period (2005–2013). The Hct data were from an 8-year period (2006–2013). The standard deviation index (SDI), defined as: (measured value of the institution - average of the participating institutions)/standard deviation of the participating institutions, was used for evaluation. The higher the absolute SDI value, the more inferior the results, as they are less similar to the average of the participating institutions. First, we compared the SDI of all five items according to whether laboratories were KLAP-certified using diagnostic blood test result data from the 9-year KEQAS. SDI mean values were compared using the Student's t-test; significance was assigned at P<0.05. Compared with non-KLAP accredited laboratories, accredited laboratories showed significantly lower geometric means for all 9-year SDI in Hb, 3-year SDI in Hct and WBCs, 5-year SDI in RBCs, and 2-year SDI in platelets (all P<0.05; Table 1).
Table 1

Comparison of standard deviation index between accredited and non-accredited laboratories

YearNon-accredited laboratoriesAccredited laboratoriesP
N*SDI95% CINSDI95% CI
Hb20052900.73[0.68 0.78]1720.52[0.47 0.57]< 0.01
20063810.85[0.79 0.92]1800.68[0.62 0.74]< 0.01
20073720.66[0.61 0.72]1890.55[0.50 0.60]< 0.01
20084500.71[0.66 0.75]2010.58[0.54 0.62]< 0.01
20096520.85[0.81 0.89]2150.62[0.58 0.65]< 0.01
20107780.71[0.67 0.74]2300.49[0.45 0.52]< 0.01
20118500.93[0.89 0.97]2420.62[0.58 0.66]< 0.01
20129110.66[0.63 0.69]2550.47[0.43 0.50]< 0.01
201310250.82[0.78 0.85]2610.56[0.52 0.60]< 0.01
Hct20063810.77[0.72 0.82]1800.77[0.71 0.84]0.91
20073720.70[0.66 0.75]1890.74[0.68 0.80]0.38
20084500.74[0.70 0.79]2010.66[0.61 0.71]< 0.01
20096520.71[0.67 0.74]2150.79[0.73 0.86]0.02
20107780.66[0.63 0.69]2300.71[0.65 0.77]0.20
20118500.71[0.67 0.74]2420.94[0.87 1.02]< 0.01
20129110.69[0.66 0.72]2550.84[0.79 0.89]< 0.01
201310250.74[0.71 0.77]2610.79[0.73 0.86]0.19
RBC20052900.72[0.67 0.78]1720.52[0.48 0.57]< 0.01
20063810.80[0.74 0.86]1800.73[0.68 0.79]0.12
20073720.69[0.64 0.74]1890.63[0.59 0.68]0.13
20084500.68[0.64 0.73]2010.67[0.63 0.72]0.78
20096520.78[0.74 0.83]2150.64[0.59 0.69]< 0.01
20107780.68[0.64 0.71]2300.53[0.49 0.58]< 0.01
20118500.78[0.74 0.82]2420.68[0.62 0.74]< 0.01
20129110.20[0.19 0.22]2550.16[0.15 0.18]< 0.01
201310250.82[0.79 0.86]2610.60[0.57 0.64]< 0.00
WBC20052900.65[0.60 0.71]1720.59[0.54 0.65]0.13
20063810.86[0.79 0.94]1800.77[0.69 0.85]0.09
20073720.67[0.62 0.73]1890.65[0.59 0.72]0.67
20084500.67[0.62 0.72]2010.60[0.56 0.65]0.05
20096520.89[0.84 0.95]2150.81[0.74 0.88]0.07
20107780.68[0.64 0.71]2300.60[0.56 0.65]0.01
20118500.84[0.80 0.88]2420.73[0.67 0.78]< 0.01
20129110.43[0.41 0.45]2550.37[0.35 0.39]< 0.01
201310250.80[0.77 0.84]2610.74[0.70 0.79]0.04
Platelet20052900.68[0.63 0.73]1720.71[0.66 0.76]0.44
20063810.76[0.71 0.81]1800.84[0.77 0.91]0.08
20073720.68[0.64 0.73]1890.75[0.69 0.81]0.07
20084500.67[0.63 0.71]2010.77[0.73 0.82]< 0.01
20096520.73[0.69 0.76]2150.73[0.68 0.79]0.86
20107780.67[0.64 0.71]2300.86[0.80 0.92]< 0.01
20118500.72[0.68 0.75]2420.78[0.72 0.85]0.07
20129110.68[0.65 0.71]2550.72[0.67 0.76]0.25
201310250.75[0.72 0.78]2610.70[0.65 0.75]0.09

*Number of laboratories; †Values represent the geometric mean; ‡P-value by Student's t-test using the log-transformed values.

Abbreviations: SDI, standard deviation index; RBC, red blood cell; WBC, white blood cell; CI, confidence interval; Hb, hemoglobin; Hct, hematocrit.

Second, the SDI of Hb test results was analyzed statistically in KEQAS according to KLAP certification status and institutional type. Participating institutes were categorized as general hospitals with>100 beds, hospitals with 30-99 beds, and clinics with <30 beds. For the 9-year Hb test data, laboratories with KLAP accreditation showed significantly lower geometric means of 8-year SDI in general hospitals, 1-year SDI in hospitals, and 7-year SDI in clinics compared with laboratories without KLAP accreditation (all P<0.05; Table 2).
Table 2

Comparison of hemoglobin standard deviation index between accredited and non-accredited laboratories by institutional type

YearGeneral HospitalPHospitalPClinicP
Non-accredited laboratoriesAccredited laboratoriesNon-accredited laboratoriesAccredited laboratoriesNon-accredited laboratoriesAccredited laboratories
N*SDINSDINSDINSDINSDINSDI
20051120.681560.530.00780.8050.620.48560.67110.40< 0.01
20061210.771630.670.081091.0051.150.761020.74120.560.24
20071130.601710.550.311080.7560.780.941020.60120.460.27
20081150.681830.580.021420.7760.810.851350.63120.500.03
20091250.801940.630.002410.8780.530.092070.85130.520.01
20101230.632030.490.003060.73110.470.022670.72150.42< 0.01
20111240.772100.610.003410.99140.950.872960.93170.55< 0.01
20121200.542170.460.043800.71170.590.233220.67200.41< 0.01
20131510.742190.550.004330.85200.700.113430.84210.51< 0.01

*Number of laboratories; †Values representthe geometric mean; ‡P-value by Student's t-test using the log-transformed values.

Abbreviation: see Table 1.

Clinical chemistry results were reported to be more accurate and reliable in KLAP-accredited laboratories [3]. However, the present diagnostic hematology results show that practice standardization did not significantly affect test results, except for the Hb test item. There are several differences between diagnostic hematology and clinical chemistry tests [4567]. Most diagnostic hematology instruments use flow cytometry cell counting, but use spectrophotometry to measure Hb values. Spectrophotometry is widely used in clinical chemistry, while flow cytometry exhibits high precision with low uncertainty. In other words, product standardization, conducted prior to practice standardization, is already excellent; thus, practice standardization will have little effect on the results. It can be assumed that only Hb values are meaningful for all the analysis years, while the other test items exhibit varying significance depending on year. In conclusion, diagnostic test practice standardization is useful for obtaining more reliable and accurate test results; however, the degree of improvement will depend on the particular test measurement principles in diagnostic hematology.
  7 in total

1.  The new hematology analyzer Sysmex XE-2100: performance evaluation of a novel white blood cell differential technology.

Authors:  K Ruzicka; M Veitl; R Thalhammer-Scherrer; I Schwarzinger
Journal:  Arch Pathol Lab Med       Date:  2001-03       Impact factor: 5.534

2.  Twenty-years of experiences in external quality assurance in Korea.

Authors:  H I Cho
Journal:  Southeast Asian J Trop Med Public Health       Date:  1999       Impact factor: 0.267

3.  Evaluation of the nucleated red blood cell count in neonates using the Beckman Coulter UniCel DxH 800 analyzer.

Authors:  M-J Kwon; M-H Nam; S H Kim; C S Lim; C K Lee; Y Cho; K N Lee; S-Y Yoon
Journal:  Int J Lab Hematol       Date:  2011-06-01       Impact factor: 2.877

4.  Performance evaluation of the ADVIA 2120 hematology analyzer: an international multicenter clinical trial.

Authors:  Neil Harris; Josep Maria Jou; Gianluigi Devoto; J Lotz; James Pappas; David Wranovics; Mary Wilkinson; Suzanne R Fletcher; Alexander Kratz
Journal:  Lab Hematol       Date:  2005

5.  [Evaluation of the Abbott Cell-Dyn Sapphire hematology analyzer].

Authors:  Younhee Park; Jaewoo Song; Sungwook Song; Kyung Soon Song; Mee Suk Ahn; Mi-Sook Yang; Il Kim; Jong Rak Choi
Journal:  Korean J Lab Med       Date:  2007-06

6.  The implementation and effects of a clinical laboratory accreditation program in Korea from 1999 to 2006.

Authors:  Bo-Moon Shin; Seok-Lae Chae; Won-Ki Min; Wee Gyo Lee; Young Ae Lim; Do Hoon Lee; Hwan Sub Lim; You Kyoung Lee; Young-Joo Cha; Soon-Pal Suh; Kap No Lee; Yun Sik Kwak
Journal:  Korean J Lab Med       Date:  2009-04

7.  Effect of Accreditation on Accuracy of Diagnostic Tests in Medical Laboratories.

Authors:  Mi Ae Jang; Young Ahn Yoon; Junghan Song; Jeong Ho Kim; Won Ki Min; Ji Sung Lee; Yong Wha Lee; You Kyoung Lee
Journal:  Ann Lab Med       Date:  2017-05       Impact factor: 3.464

  7 in total
  1 in total

1.  Utility of process capability indices in assessment of quality control processes at a clinical laboratory chain.

Authors:  Ping Dong; Yong-Bo Wang; De-Zhi Peng; Jia-Jia Wang; Ya-Ting Cheng; Xiao-Yan Deng; Biao Zheng; Ran Tao
Journal:  J Clin Lab Anal       Date:  2021-06-24       Impact factor: 2.352

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.