Literature DB >> 15790554

Performance evaluation of the ADVIA 2120 hematology analyzer: an international multicenter clinical trial.

Neil Harris1, Josep Maria Jou, Gianluigi Devoto, J Lotz, James Pappas, David Wranovics, Mary Wilkinson, Suzanne R Fletcher, Alexander Kratz.   

Abstract

Automated cell counters are widely used in modern clinical laboratories to provide reliable, fast, and cost-effective complete blood counts (CBCs), white blood cell differentials, and reticulocyte measurements. In addition, some advanced instruments provide novel parameters, such as the hemoglobin content of reticulocytes or the percentage of hypochromic cells, and are capable of analysis of a variety of body fluids. Bayer recently introduced the ADVIA 2120 system as an automation-ready cell counter for mid- to high-volume testing in the clinical laboratory. This instrument, which builds on the established technology of the ADVIA 120 system, operates with a cyanide-free method for hemoglobin measurement, has a new user interface, and can routinely analyze biological fluid samples in addition to blood. We used 749 samples from 6 worldwide trial sites to evaluate the clinical performance of this new device. Accuracy of the ADVIA 2120 system versus its predecessor model, the ADVIA 120 system, was excellent for all CBC and white cell differential parameters and reticulocyte counts (all correlation coefficients except for basophils >0.9). Correlation of the white cell differential with the standard manual method and within-run precision of the ADVIA 2120 system also was very good. Use of the novel cyanide-free method for hemoglobin measurement had no clinically significant impact on hemoglobin results, even in patients with hemoglobinopathies. We concluded that the ADVIA 2120 system has clinically equivalent performance to the ADVIA 120 system.

Entities:  

Mesh:

Year:  2005        PMID: 15790554     DOI: 10.1532/LH96.04064

Source DB:  PubMed          Journal:  Lab Hematol        ISSN: 1080-2924


  31 in total

1.  Influence of a light meal on routine haematological tests.

Authors:  Giuseppe Lippi; Gabriel Lima-Oliveira; Gian Luca Salvagno; Martina Montagnana; Matteo Gelati; Geraldo Picheth; Alberto José Duarte; Massimo Franchini; Gian Cesare Guidi
Journal:  Blood Transfus       Date:  2010-04       Impact factor: 3.443

2.  Untargeted metabolomics profiling and hemoglobin normalization for archived newborn dried blood spots from a refrigerated biorepository.

Authors:  Miao Yu; Georgia Dolios; Vladimir Yong-Gonzalez; Olle Björkqvist; Elena Colicino; Jonas Halfvarson; Lauren Petrick
Journal:  J Pharm Biomed Anal       Date:  2020-08-23       Impact factor: 3.935

3.  Interference of in vitro hemolysis complete blood count.

Authors:  Gabriela de Jonge; Talita L Dos Santos; Bruno R Cruz; Mackelly Simionatto; Jeanine I M Bittencourt; Everson A Krum; Mariane F Moss; Danielle Cristyane K Borato
Journal:  J Clin Lab Anal       Date:  2018-02-03       Impact factor: 2.352

4.  Foot-strike haemolysis after a 60-km ultramarathon.

Authors:  Giuseppe Lippi; Federico Schena; Gian Luca Salvagno; Rosalia Aloe; Giuseppe Banfi; Gian Cesare Guidi
Journal:  Blood Transfus       Date:  2012-05-17       Impact factor: 3.443

5.  Delta neutrophil index: A reliable marker to differentiate perforated appendicitis from non-perforated appendicitis in the elderly.

Authors:  Dong Hyuk Shin; Young Suk Cho; Yoon Sung Kim; Hee Cheol Ahn; Young Taeck Oh; Sang O Park; Moo-Ho Won; Jun Hwi Cho; Young Myeong Kim; Jeong Yeol Seo; Young Hwan Lee
Journal:  J Clin Lab Anal       Date:  2017-02-26       Impact factor: 2.352

6.  Two different hematocrit detection methods: different methods, different results?

Authors:  Marco Bosshart; John F Stover; Reto Stocker; Lars M Asmis; Jörg Feige; Thomas A Neff; Reto A Schuepbach; Silvia R Cottini; Markus Béchir
Journal:  BMC Res Notes       Date:  2010-03-09

7.  Platelet factor 4 is a negative autocrine in vivo regulator of megakaryopoiesis: clinical and therapeutic implications.

Authors:  Michele P Lambert; Lubica Rauova; Matthew Bailey; Martha C Sola-Visner; M Anna Kowalska; Mortimer Poncz
Journal:  Blood       Date:  2007-05-10       Impact factor: 22.113

8.  Inhibition of CD203c membrane up-regulation in human basophils by high dilutions of histamine: a controlled replication study.

Authors:  Salvatore Chirumbolo; Maurizio Brizzi; Riccardo Ortolani; Antonio Vella; Paolo Bellavite
Journal:  Inflamm Res       Date:  2009-05-06       Impact factor: 4.575

9.  Perioperative factors associated with 1-year mortality after lung transplantation: a single-center experience in Korea.

Authors:  Su Hwan Lee; Moo Suk Park; Joo Han Song; Young Sam Kim; Jin Gu Lee; Hyo Chae Paik; Song Yee Kim
Journal:  J Thorac Dis       Date:  2017-10       Impact factor: 2.895

10.  Heterogeneity in Hematological Parameters of High and Low Altitude Tibetan Populations.

Authors:  Nipa Basak; Tsering Norboo; Mohammed S Mustak; Kumarasamy Thangaraj
Journal:  J Blood Med       Date:  2021-05-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.