Literature DB >> 29063011

Polymer-free versus permanent polymer drug eluting stents in coronary artery disease: A meta-analysis of 10 RCTs with 6575 patients.

De-Wei Wu1, Meng-Yue Yu1, Hai-Yang Gao1, Li Zhang1, Fei Song1, Xin-Yue Zhang1, Yong-Jian Wu1.   

Abstract

BACKGROUND: Permanent polymer drug eluting stents (PP-DES) may induce inflammation of the vessel wall due to the existence of the polymer, which may delay intimal healing. Polymer-free DES (PF-DES) that eliminate the polymeric carrier may potentially lead to safer DES. However, the safety and efficacy of PF-DES remains controversial.
METHODS: Randomized controlled trials comparing PF-DES with PP-DES were searched in online database including MEDLINE, Excerpta Medica Database (EMBASE) and Cochrane Library. Studies reporting late lumen loss (LLL), all-cause death, myocardial infarction (MI), target lesion revascularization (TLR) and late stent thrombosis (LST) were enrolled and quantitatively analyzed.
RESULTS: Ten studies enrolling 6575 patients were included in this meta-analysis. The PF-DES showed a benefit in reducing all-cause death (OR = 0.77, 95% CI: 0.61 to 0.98, P = 0.03) and long-term LLL (weighted mean difference (WMD) -0.16 mm, 95% CI: -0.22 to -0.11 mm, P < 0.001), while no superiority was found in reducing short-term LLL (WMD 0.03 mm, 95% CI: -0.07-0.13 mm, P = 0.57), MI (OR = 1.12, 95% CI: 0.19 to 23.18, P = 0.39), TLR (OR = 1.19, 95% CI: 0.42 to 3.38, P = 0.83) and LST (OR = 0.92, 95% CI: 0.05 to 5.71, P = 0.74).
CONCLUSION: PF-DES showed benefits in reducing long-term LLL and mortality compared with PP-DES, but no superiority was found in short-term LLL, MI, TLR and LST. These findings provide a sound basis for the wide application of PF-DES in the future.

Entities:  

Keywords:  Drug eluting stent; Meta-analysis; Polymer-free DES

Year:  2016        PMID: 29063011      PMCID: PMC5643741          DOI: 10.1016/j.cdtm.2016.01.001

Source DB:  PubMed          Journal:  Chronic Dis Transl Med        ISSN: 2095-882X


Introduction

Drug eluting stents (DES) coated with anti-proliferative agents have been proven to reduce the incidence of restenosis and target lesion revascularization (TLR) by inhibition of neointimal hyperplasia.1, 2 However, DES are also associated with a higher rate of late stent thrombosis (LST) as compared with bare metal stents (BMS).3, 4 A permanent polymer coating is used to bind the anti-proliferative drugs to the stent platform and control the drug release. The polymer stays in situ after the drug is released, which can cause chronic inflammation and can delay the endothelial healing.5, 6 Therefore, efforts have been made to develop stents with biodegradable polymers or with polymer-free surfaces. There have been several studies of whether polymer-free stents can produce a better clinical outcome compared with permanent polymer stents but there are conflicting results about the clinical outcomes. This meta-analysis aims to summarize the data from randomized controlled trials (RCT) comparing permanent polymer DES (PP-DES) with polymer-free DES (PF-DES).

Methods

Search strategy

The meta-analysis was performed according to the Cochrane handbook for systematic reviews of interventions 5.1.0. A systematic review was performed in MEDLINE, EMBASE, Cochrane Library, Scopus, Highwire Press and Google Scholar databases for publications until December, 2015. The search was conducted without language restriction by two independent investigators using the keywords “stent”, “drug eluting”, “polymer-free”, “nonpolymer”, “polymer” and “randomized”. Endnote X6 was used to build a library of references and to erase duplicated results. Meeting abstracts that provided sufficient data were also included. Studies with overlapping data were excluded.

Selection criteria

The citations were screened at the title and abstract level then retrieved as full reports. Inclusion criteria included the following: 1) RCTs comparing PF-DES with PP-DES; 2) studies reporting clinical outcomes as all-cause death and/or cardiac death and/or myocardial infarction (MI) and/or TLR and/or LST consistent with Academy Research Consortium (ARC) definition and/or in-stent late lumen loss (LLL) and 3) a follow-up period longer than six months with or without quantitative coronary angiography reexamination. Exclusion criteria were: 1) duplicated reporting (in which studies with the longest follow-up time were selected); 2) using BMS or biodegradable polymer DES (BP-DES) or bioabsorbable scaffold stents or other peculiar stents. Data were abstracted on pre-specified forms by two unblinded reviewers and divergences of opinion were resolved by consensus.

Quality assessment

The quality assessment was performed according to the Cochrane handbook for systematic reviews of interventions 5.1.0. The quality of the studies included was appraised by two unblinded investigators. The risk of selection, performance, detection, attrition, reporting and other bias was qualified as a low risk of bias, an unclear risk of bias or a high risk of bias as recommended. The initial protocols registered in clinicaltrial.gov (https://clinicaltrials.gov/) were screened when qualifying a reporting bias.

Date extraction

Two blinded reviewers independently performed data extraction. Disagreements between the reviewers were resolved through discussion or by the third reviewer. The extracted data included: (1) first author's last name, the publication year; (2) characteristics of the study population, (3) stent types, duration of follow-up, (4) study design, and (5) study endpoints.

Endpoints and definitions

The composite endpoint of major adverse cardiovascular events (MACEs) was defined as the composite of all-cause death, MI, or ischemia-driven TLR. Definite or probable stent thrombosis was adjudicated using the Academic Research Consortium definite or probable criteria.

Data analysis

Review manager 5.2.6 was used for all analyses. Odds ratios (ORs) were computed from individual studies and pooled according to a fixed effect or random effect model in case of statistical heterogeneity. Outcomes appraised were all-cause death, MI, TLR, MACEs, LST, and in-stent LLL. We used the Mantel-Haenszel method for combining ORs of binary outcomes. The mean difference of followed-up LLL compared with baseline was used for the in-stent LLL outcomes, and the overall weighted mean difference (WMD) was built with the inverse variance method, as recommended. We assessed the heterogeneity between eligible studies by the Cochrane Q test. We considered P values less than 0.10 as an indicator of significant heterogeneity because of the low statistical power. We also used the inconsistency index I2 to quantify heterogeneity. Funnel plots were constructed to assess publication bias.

Results

Literature search and eligible studies

The review process is presented in Fig. 1. The literature search resulted in 140 relevant outcomes after duplicates removed. We excluded 100 reviews and irrelevant studies, and 11 studies were removed after closer inspection. The specific reasons for their exclusion were: 1) non-randomized studies or registries studies, 2) used BMS or BP-DES or other peculiar stent technologies. We excluded duplicated reports of the same studies. Finally, we considered 11 appropriate studies, one of which did not provide necessary data and it was excluded from this meta-analysis.
Fig. 1

Flow diagram of the review process.

Flow diagram of the review process. The 10 studies10, 11, 12, 13, 14, 15, 16, 17, 18, 19 enrolling 6575 patients were included in the meta-analysis. Study follow-up duration ranged from 1 to 5 years. In ISAR-TEST-3, Byrne et al compared the clinical outcomes of three different polymer coating strategies (PP-DES, BP-DES and PF-DES), and we only extracted data about PP-DES and PF-DES. In the ISAR-TEST-2, Byrne et al compared PF-DES with two types of PP-DES, so we combined the data of the two types of PP-DES. The risk of bias assessment is presented in Fig. 2. There was no publication bias according to the funnel plot of each endpoint (Fig. 3). The main characteristics are presented in Table 1 and Table 2.
Fig. 2

Risk of bias judgment.

Fig. 3

Funnel plot of comparison Polymer-free drug eluting stents (PF-DES) vs. Permanent polymer drug eluting stents (PP-DES): outcome: in-stent late stent thrombosis. Funnel plot displays no publication bias about the end-point of late stent thrombosis (LST), as demonstrated by the absence of graphical asymmetrical distribution.

Table 1

Characteristics of included studies.

AuthorJournalAcronymPatientsTotal patientsPF-DESPF-DES drugPF-DES patientsPP-DESPP-DES drugPP-DES patientsFollow up time (year)
ByrneHeart 2009ISAR-TEST-3CAD4032% rapamycinSirolimus201CypherSirolimus2022
ByrneJACC 2010ISAR-TEST-2CAD1007Dual-DESSirolimus, probucol333Cypher,EndeavorSirolimus, zotarolimus6742
CarrieJACC 2011CAD296Cre8Amphilimus148Taxus LibertePaclitaxel1481
DangChin Med J (Engl) 2012STEMI105YinyiPaclitaxel50PartnerSirolimus551
MassbergCirculation 2011ISAR-TEST-5CAD450Dual-DESSirolimus, probucol225ResoluteZotarolimus2251
KingCatheter Cardiovasc Interv. 2013ISAR-TESTCAD3002YukonSirolimus2002TaxusPaclitaxel10005
ShiratoriCatheter Cardiovasc Interv. 2014CAD164AxxionPaclitaxel80TAXUS ExpressPaclitaxel842
StiermaierCatheter Cardiovasc Interv. 2013LIPSIA YukonCAD&DM232Yukon ChoiceSirolimus118Taxus LibertePaclitaxel1145
ZhangInt J Cardiol 2013CAD648YinyiPaclitaxel327PartnerSirolimus3212
ZhangChin Med J (Engl) 2014CAD268NanoSirolimus132PartnerSirolimus1362

PF-DES: polymer-free drug eluting stents, PP-DES: permanent polymer drug eluting stents, CAD: coronary artery disease, STEMI: ST elevated myocardial infarction, DM: diabetes mellitus.

Table 2

Features of clinical trials included after full-text inspection.

StudyAge (years)Male (%)Smoking (%)HBP (%)Dyslipidemia (%)Diabetes (%)ACS (%)Prior MIPrior PCIPrior CABGType B2/C lesions (%)Lesion length
Byrne 200966.0 ± 10.279.916.465.867.527.030.533.3NA10.4NA14.45 ± 6.14
Byrne 201066.9 ± 11.166.718.466.765.727.441.827.0NA8.8372.514.46 ± 8.17
Carrie 201164.6 ± 10.372.124.564.461.926.9NA9.015.2NA31.315.28 ± 7.03
Dang 201266.2 ± 13.169.564.843.821.925.71005.71.9NA56.7NA
Massberg 201167.8 ± 11.176.417.466.763.529.041.029.5NA9.574.116.57 ± 9.74
King 201366.7 ± 10.376.918.266.074.429.142.931.8NA11.176.412.75 ± 6.47
Shiratori 201466.5 ± 9.372.618.973.261.632.342.731.128.96.173.815.91 ± 8.81
Stiermaier 201367.1 ± 9.368.625.097.5NA100NA22.030.17.636.416.74 ± 4.63
Zhang 201365.6 ± 10.867.040.064.8NA26.585.5NANANA87.7NA
Zhang 201457.4 ± 10.476.851.653.531.116.8NA30.214.8NANA23.6 ± 13.5

HBP: high blood pressure, ACS: acute coronary syndrome, MI: myocardial infarction, PCI: percutaneous coronary intervention, CABG: coronary artery bypass grafting.

Risk of bias judgment. Funnel plot of comparison Polymer-free drug eluting stents (PF-DES) vs. Permanent polymer drug eluting stents (PP-DES): outcome: in-stent late stent thrombosis. Funnel plot displays no publication bias about the end-point of late stent thrombosis (LST), as demonstrated by the absence of graphical asymmetrical distribution. Characteristics of included studies. PF-DES: polymer-free drug eluting stents, PP-DES: permanent polymer drug eluting stents, CAD: coronary artery disease, STEMI: ST elevated myocardial infarction, DM: diabetes mellitus. Features of clinical trials included after full-text inspection. HBP: high blood pressure, ACS: acute coronary syndrome, MI: myocardial infarction, PCI: percutaneous coronary intervention, CABG: coronary artery bypass grafting.

Outcome analysis

All-cause death

A fixed effect model was used to build up the quantitative analysis for all-cause death given that no heterogeneity was found. The 10 studies that enrolled 6539 patients were included in the analysis. Compared with PP-DES, PF-DES significantly decreased the all-cause death rate (OR = 0.77, 95% CI: 0.61 to 0.98, P = 0.03) (Fig. 4).
Fig. 4

Individual and summary odds ratios for all-causes death in patients treated by PF-DES and PP-DES implantation. PF-DES: polymer-free drug eluting stents, PP-DES: permanent polymer drug eluting stents, M–H: Mantel-Haenszel method.

Individual and summary odds ratios for all-causes death in patients treated by PF-DES and PP-DES implantation. PF-DES: polymer-free drug eluting stents, PP-DES: permanent polymer drug eluting stents, M–H: Mantel-Haenszel method.

Myocardial infarction

A fixed effect model was used for the quantitative analysis as we found no heterogeneity. Compared with PP-DES, no significant benefit was found in the PF-DES group (OR = 1.12, 95% CI: 0.19 to 23.18, P = 0.39) (Fig. 5).
Fig. 5

Individual and summary odds ratios for myocardial infraction in patients treated by PF-DES and PP-DES implantation. PF-DES: polymer-free drug eluting stents, PP-DES: permanent polymer drug eluting stents, M–H: Mantel-Haenszel method.

Individual and summary odds ratios for myocardial infraction in patients treated by PF-DES and PP-DES implantation. PF-DES: polymer-free drug eluting stents, PP-DES: permanent polymer drug eluting stents, M–H: Mantel-Haenszel method.

Target lesion revascularization

The result of TLR was available in 10 studies. We used a fixed effect model to perform the quantitative analysis as no heterogeneity was found. The PF-DES group showed no significant benefit compared with the PP-DES group (OR = 1.19, 95% CI: 0.42 to 3.38, P = 0.83) (Fig. 6).
Fig. 6

Individual and summary odds ratios for target lesion revascularization in patients treated by PF-DES and PP-DES implantation. PF-DES: polymer-free drug eluting stents, PP-DES: permanent polymer drug eluting stents, M–H: Mantel-Haenszel method.

Individual and summary odds ratios for target lesion revascularization in patients treated by PF-DES and PP-DES implantation. PF-DES: polymer-free drug eluting stents, PP-DES: permanent polymer drug eluting stents, M–H: Mantel-Haenszel method.

MACEs

Three of the studies met the definition of MACEs in our analysis. In other studies, we calculated the MACEs according to the corresponding results. A random effect model was used to perform the meta-analysis. The two kinds of stents showed similar results in MACEs (OR = 0.99, 95% CI: 0.79 to 1.24, P = 0.91) (Fig. 7).
Fig. 7

Individual and summary odds ratios for major adverse cardiovascular events in patients treated by PF-DES and PP-DES implantation. PF-DES: polymer-free drug eluting stents, PP-DES: permanent polymer drug eluting stents, M–H: Mantel-Haenszel method.

Individual and summary odds ratios for major adverse cardiovascular events in patients treated by PF-DES and PP-DES implantation. PF-DES: polymer-free drug eluting stents, PP-DES: permanent polymer drug eluting stents, M–H: Mantel-Haenszel method.

Late stent thrombosis

We extracted definite or probable LST for further analysis. A fixed effect model was used to build up the quantitative analysis as no heterogeneity was found. The PF-DES and the PP-DES showed similar rates of LST (OR = 0.92, 95% CI: 0.05 to 5.71, P = 0.74) (Fig. 8).
Fig. 8

Individual and summary odds ratios for definite or probable late stent thrombosis in patients treated by PF-DES and PP-DES implantation. PF-DES: polymer-free drug eluting stents, PP-DES: permanent polymer drug eluting stents, M–H: Mantel-Haenszel method.

Individual and summary odds ratios for definite or probable late stent thrombosis in patients treated by PF-DES and PP-DES implantation. PF-DES: polymer-free drug eluting stents, PP-DES: permanent polymer drug eluting stents, M–H: Mantel-Haenszel method.

Late lumen loss

A random effect model was used to perform the meta-analysis given the degree of heterogeneity found. Two of the studies10, 11 performed angiography twice during follow-up (once in 6–8 month, once in 2 years), while in three studies12, 13, 14 it was performed once in 6–9 months. We built a meta-analysis for both short term LLL (6–9 months) and long term LLL (2 years). In the early phases, PF-DES showed no benefit in reducing LLL compared with PP-DES (WMD 0.03 mm 95% CI: −0.07 to 0.13 mm, P = 0.57). However, after reviewing the 2 years outcome, the PF-DES showed a significantly lower in-stent LLL (OR = 0.77, 95% CI: 0.61 to 0.98, P = 0.03) (Fig. 9).
Fig. 9

Individual and summary odds ratios for in-stent lumen loss in patients treated by PF-DES and PP-DES implantation at short (6–9 months) or long (2 years) term. PF-DES: polymer-free drug eluting stents, PP-DES: permanent polymer drug eluting stents, IV: inverse variance method.

Individual and summary odds ratios for in-stent lumen loss in patients treated by PF-DES and PP-DES implantation at short (6–9 months) or long (2 years) term. PF-DES: polymer-free drug eluting stents, PP-DES: permanent polymer drug eluting stents, IV: inverse variance method.

Discussion

The main finding of this meta-analysis is that compared with PP-DES, PF-DES showed superiority in reducing long-term LLL and all-cause mortality, while showed no significant benefit on short-term LLL, MI, TLR and LST. It has been demonstrated that vascular wall inflammation may be induced after PP-DES implanted in pigs20, 21 and humans.22, 23 This inflammation is considered to cause delayed intimal healing, late malapposition and LST, and it may have an important etiological role in adverse events late after stent implantation. Permanent polymer can also aggravate neointimal atherosclerosis compared with BMS which could induce more adverse events. Considering that, intimal inflammation and LST have become a bottleneck problem restricting the development of DES. As a consequence, both BP-DES and PF-DES have been the focus of and have been developed. BP-DES showed superiority in reducing TLR and LLL but without clear benefits for mortality, MI, and LST. Nevertheless, studies also reported late inflammation after BP-DES implantation.22, 27 Several studies have evaluated the safety and efficiency of PF-DES involving different types of stent coating different agents including Paclitaxel,16, 28 sirolimus,10, 11, 13, 14, 15 biolimus and amphilimus. This meta-analysis included 10 studies comparing polymer-free paclitaxel, sirolimus and amphilimus eluting stents with PP-DES with 1–5 years follow-up duration. PF-DES coated with biolimus were not included due to absence of the necessary data. Given that two (2)10, 11 of the studies didn't provide data on cardiac death, we analyzed rates of all-cause death to evaluate the efficiency of PF-DES in reducing mortality. It showed that PF-DES could significantly reduce mortality without any detectable heterogeneity so that this may be convincing evidence in the evaluation of PF-DES. Another noteworthy finding of this meta-analysis was that compared with PP-DES, PF-DES had a similar LLL 6–9 months after stent implantation, while it showed significant benefit in long-term follow-up. Because of a higher speed of drug release (∼75% in the first 10 days), PF-DES may have relatively higher initial lumen loss in 6–9 months compared with PP-DES. However, it may consequently prompt earlier and more complete vessel healing than PP-DES. It has been demonstrated that additional lumen loss was found in PP-DES implanted vessels even beyond 6–9 months.30, 31 It might also be proposed that existence of a polymer induced more inflammation and higher lumen loss. No benefit in reducing TLR, MI and LST of PF-DES was found in this meta-analysis. Among the 10 studies, two (2) of them had a 5-year follow-up time while the other eight (8) studies followed up for 1 or 2 years. A short duration of follow-up might make it difficult to detect endpoints with low incidences even though we had a large sample size. Further studies with larger sample size and longer follow-up duration need to be performed in the future.

Limitations

We did not have access to the data of the Biofreedom FIM study, even though we made a great effort, and it might have been important for this analysis. The coating agents and follow-up duration ranged among different studies, which lead to heterogeneity in the analysis. Finally, we could not get access to individual patient data which prevented us from making subgroup analysis; such as acute coronary syndrome, diabetes, and other meaningful clinical conditions.

Conclusion

In this meta-analysis, PF-DES showed benefit on reducing long-term LLL and all-cause mortality compared with PP-DES, but no superiority was found in short-term LLL, MI, TLR and LST. These findings provide a sound basis to wide application of PF-DES in the future.

Conflicts of interest

None.
  29 in total

1.  A multicenter randomized trial comparing amphilimus- with paclitaxel-eluting stents in de novo native coronary artery lesions.

Authors:  Didier Carrié; Jacques Berland; Stefan Verheye; Karl Eugen Hauptmann; Mathias Vrolix; Roberto Violini; Alain Dibie; Sergio Berti; Eric Maupas; David Antoniucci; Joachim Schofer
Journal:  J Am Coll Cardiol       Date:  2012-01-25       Impact factor: 24.094

2.  Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk.

Authors:  Michael Joner; Aloke V Finn; Andrew Farb; Erik K Mont; Frank D Kolodgie; Elena Ladich; Robert Kutys; Kristi Skorija; Herman K Gold; Renu Virmani
Journal:  J Am Coll Cardiol       Date:  2006-05-05       Impact factor: 24.094

3.  Four-year angiographic and intravascular ultrasound follow-up of patients treated with sirolimus-eluting stents.

Authors:  J Eduardo Sousa; Marco A Costa; Alexandre Abizaid; Fausto Feres; Ana C Seixas; Luiz F Tanajura; Luiz A Mattos; Robert Falotico; Judith Jaeger; Jeffrey J Popma; Patrick W Serruys; Amanda G M R Sousa
Journal:  Circulation       Date:  2005-04-25       Impact factor: 29.690

4.  Tissue response to partially in vitro predegraded poly-L-lactide implants.

Authors:  Wim H De Jong; J Eelco Bergsma; Joke E Robinson; Ruud R M Bos
Journal:  Biomaterials       Date:  2005-05       Impact factor: 12.479

5.  Two-year clinical outcomes of different drug-eluting stents with different polymer coating strategies in coronary artery heart disease: a multi-centre, randomised, controlled clinical trial.

Authors:  Yue Zhang; Junle Shen; Zhifeng Li; Aidong Zhu; Yuelong Yuan; Ruihua Yue; Jia Yuan; Yuehui Yin; Qiang She; Yunqing Chen
Journal:  Int J Cardiol       Date:  2013-04-12       Impact factor: 4.164

6.  Randomized comparison between polymer-free versus polymer-based paclitaxel-eluting stent: two-year final clinical results.

Authors:  Yoshitaka Shiratori; Clarissa Cola; Salvatore Brugaletta; Luis Alvarez-Contreras; Victoria Martín-Yuste; Bruno García del Blanco; Rafael Ruiz-Salmeron; Jose Díaz; Eduardo Pinar; Vicens Martí; Juan García-Picart; Manel Sabaté
Journal:  Circ Cardiovasc Interv       Date:  2014-05-06       Impact factor: 6.546

7.  Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis.

Authors:  Stéphane Cook; Elena Ladich; Gaku Nakazawa; Parham Eshtehardi; Michel Neidhart; Rolf Vogel; Mario Togni; Peter Wenaweser; Michael Billinger; Christian Seiler; Steffen Gay; Bernhard Meier; Werner J Pichler; Peter Jüni; Renu Virmani; Stephan Windecker
Journal:  Circulation       Date:  2009-07-20       Impact factor: 29.690

8.  Six-month angiographic and one-year clinical outcomes of polymer free paclitaxel-eluting stent in patients with ST-segment elevation myocardial infarction: a comparison with permanent polymer sirolimus-eluting stent.

Authors:  Qun Dang; Yong-Jian Li; Lu Gao; Zhe Jin; Li-Xin Gou
Journal:  Chin Med J (Engl)       Date:  2012-10       Impact factor: 2.628

9.  A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease.

Authors:  Gregg W Stone; Stephen G Ellis; David A Cox; James Hermiller; Charles O'Shaughnessy; James Tift Mann; Mark Turco; Ronald Caputo; Patrick Bergin; Joel Greenberg; Jeffrey J Popma; Mary E Russell
Journal:  N Engl J Med       Date:  2004-01-15       Impact factor: 91.245

10.  Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries.

Authors:  W J van der Giessen; A M Lincoff; R S Schwartz; H M van Beusekom; P W Serruys; D R Holmes; S G Ellis; E J Topol
Journal:  Circulation       Date:  1996-10-01       Impact factor: 29.690

View more
  2 in total

Review 1.  Polymer-Free Drug-Coated Coronary Stents in Patients with Stable Coronary Artery Disease at High Bleeding Risk.

Authors:  Hemang B Panchal; Ramesh Daggubati; David Zhao; Sunil V Rao; Timir Paul
Journal:  Curr Cardiol Rep       Date:  2017-02       Impact factor: 2.931

Review 2.  Polymer-free versus durable polymer drug-eluting stents in patients with coronary artery disease: A meta-analysis.

Authors:  James J Wu; Joshua A H Way; Leonard Kritharides; David Brieger
Journal:  Ann Med Surg (Lond)       Date:  2018-12-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.