Literature DB >> 19620501

Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis.

Stéphane Cook1, Elena Ladich, Gaku Nakazawa, Parham Eshtehardi, Michel Neidhart, Rolf Vogel, Mario Togni, Peter Wenaweser, Michael Billinger, Christian Seiler, Steffen Gay, Bernhard Meier, Werner J Pichler, Peter Jüni, Renu Virmani, Stephan Windecker.   

Abstract

BACKGROUND: Intravascular ultrasound of drug-eluting stent (DES) thrombosis (ST) reveals a high incidence of incomplete stent apposition (ISA) and vessel remodeling. Autopsy specimens of DES ST show delayed healing and hypersensitivity reactions. The present study sought to correlate histopathology of thrombus aspirates with intravascular ultrasound findings in patients with very late DES ST. METHODS AND
RESULTS: The study population consisted of 54 patients (28 patients with very late DES ST and 26 controls). Of 28 patients with very late DES ST, 10 patients (1020+/-283 days after implantation) with 11 ST segments (5 sirolimus-eluting stents, 5 paclitaxel-eluting stents, 1 zotarolimus-eluting stent) underwent both thrombus aspiration and intravascular ultrasound investigation. ISA was present in 73% of cases with an ISA cross-sectional area of 6.2+/-2.4 mm(2) and evidence of vessel remodeling (index, 1.6+/-0.3). Histopathological analysis showed pieces of fresh thrombus with inflammatory cell infiltrates (DES, 263+/-149 white blood cells per high-power field) and eosinophils (DES, 20+/-24 eosinophils per high-power field; sirolimus-eluting stents, 34+/-28; paclitaxel-eluting stents, 6+/-6; P for sirolimus-eluting stents versus paclitaxel-eluting stents=0.09). The mean number of eosinophils per high-power field was higher in specimens from very late DES ST (20+/-24) than in those from spontaneous acute myocardial infarction (7+/-10), early bare-metal stent ST (1+/-1), early DES ST (1+/-2), and late bare-metal stent ST (2+/-3; P from ANOVA=0.038). Eosinophil count correlated with ISA cross-sectional area, with an average increase of 5.4 eosinophils per high-power field per 1-mm(2) increase in ISA cross-sectional area.
CONCLUSIONS: Very late DES thrombosis is associated with histopathological signs of inflammation and intravascular ultrasound evidence of vessel remodeling. Compared with other causes of myocardial infarction, eosinophilic infiltrates are more common in thrombi harvested from very late DES thrombosis, particularly in sirolimus-eluting stents, and correlate with the extent of stent malapposition.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19620501     DOI: 10.1161/CIRCULATIONAHA.109.854398

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  86 in total

1.  In vivo PEG modification of vascular surfaces for targeted delivery.

Authors:  Timothy E Deglau; Timothy M Maul; Flordeliza S Villanueva; William R Wagner
Journal:  J Vasc Surg       Date:  2011-12-09       Impact factor: 4.268

Review 2.  Restenosis after PCI. Part 2: prevention and therapy.

Authors:  J Wouter Jukema; Tarek A N Ahmed; Jeffrey J W Verschuren; Paul H A Quax
Journal:  Nat Rev Cardiol       Date:  2011-10-11       Impact factor: 32.419

Review 3.  Applications of grayscale and radiofrequency intravascular ultrasound to image atherosclerotic plaque.

Authors:  Somjot S Brar; Gary S Mintz; Akiko Maehara; Gregg W Stone
Journal:  J Nucl Cardiol       Date:  2010-10       Impact factor: 5.952

Review 4.  Coronary stent choice in patients with acute myocardial infarction.

Authors:  Giulio G Stefanini; Stephan Windecker
Journal:  Curr Cardiol Rep       Date:  2012-08       Impact factor: 2.931

5.  Impact of stent mis-sizing and mis-positioning on coronary fluid wall shear and intramural stress.

Authors:  Henry Y Chen; Bon-Kwon Koo; Deepak L Bhatt; Ghassan S Kassab
Journal:  J Appl Physiol (1985)       Date:  2013-05-30

6.  Simultaneous stent obstruction of triple vessels with very late stent thrombosis after implantation of sirolimus-eluting stents.

Authors:  Kazutaka Mori; Satoko Hayakawa; Hitoshi Yamaguchi; Yasuhiro Shimizu; Akihiro Suzuki; Takaaki Yamada; Tomomichi Suzuki; Harumitsu Yamamoto; Masahumi Inagaki; Yasushi Tomita; Tomoki Kitano
Journal:  J Cardiol Cases       Date:  2012-03-16

Review 7.  First-generation drug-eluting stents ... and beyond.

Authors:  William Wijns
Journal:  Drug Saf       Date:  2009       Impact factor: 5.606

8.  A case of active peri-stent inflammation after sirolimus-eluting stent implantation.

Authors:  Takafumi Kurosawa; Jun-Ichi Kotani; Taka-aki Matsuyama; Hatsue Ishibashi-Ueda
Journal:  Heart Vessels       Date:  2014-01-10       Impact factor: 2.037

9.  Long-term effect of stent coating with zedoary essential components on neointimal formation in the porcine coronary artery.

Authors:  Fu-hai Zhao; Jian-gang Liu; Xin Wang; Da-wu Zhang; Pei-li Wang; Lei Zhang; Jian-peng Du; Xin-zhi Li; Yan-lei Ma; Yue Shi; Da-zhuo Shi
Journal:  Chin J Integr Med       Date:  2013-10-04       Impact factor: 1.978

10.  Stent implant follow-up in intravascular optical coherence tomography images.

Authors:  Gozde Unal; Serhan Gurmeric; Stéphane Guy Carlier
Journal:  Int J Cardiovasc Imaging       Date:  2009-09-24       Impact factor: 2.357

View more