Literature DB >> 29034514

Measurement of Murine Single-Kidney Glomerular Filtration Rate Using Dynamic Contrast-Enhanced MRI.

Kai Jiang1, Hui Tang1, Prasanna K Mishra2, Slobodan I Macura2, Lilach O Lerman1.   

Abstract

PURPOSE: To develop and validate a method for measuring murine single-kidney glomerular filtration rate (GFR) using dynamic contrast-enhanced MRI (DCE-MRI).
METHODS: This prospective study was approved by the Institutional Animal Care and Use Committee. A fast longitudinal relaxation time (T1 ) measurement method was implemented to capture gadolinium dynamics (1 s/scan), and a modified two-compartment model was developed to quantify GFR as well as renal perfusion using 16.4T MRI in mice 2 weeks after unilateral renal artery stenosis (RAS, n = 6) or sham (n = 8) surgeries. This approach was validated by comparing model-derived GFR and perfusion to those obtained by fluorescein isothiocyanante (FITC)-inulin clearance and arterial spin labeling (ASL), respectively, using the Pearson's and Spearman's rank correlations and Bland-Altman analysis.
RESULTS: The compartmental model provided a good fitting to measured gadolinium dynamics in both normal and RAS kidneys. The proposed DCE-MRI method offered assessment of single-kidney GFR and perfusion, comparable to the FITC-inulin clearance (Pearson's correlation coefficient r = 0.95 and Spearman's correlation coefficient ρ = 0.94, P < 0.0001, and mean difference -7.0 ± 11.0 μL/min) and ASL (r = 0.92 and ρ = 0.84, P < 0.0001, and mean difference 4.4 ± 66.1 mL/100 g/min) methods.
CONCLUSION: The proposed DCE-MRI method may be useful for reliable noninvasive measurements of single-kidney GFR and perfusion in mice. Magn Reson Med 79:2935-2943, 2018.
© 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  compartmental model; dynamic contrast-enhanced MRI; glomerular filtration rate; renal artery stenosis; renal perfusion

Mesh:

Substances:

Year:  2017        PMID: 29034514      PMCID: PMC5843517          DOI: 10.1002/mrm.26955

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  43 in total

1.  Renal function measurements from MR renography and a simplified multicompartmental model.

Authors:  Vivian S Lee; Henry Rusinek; Louisa Bokacheva; Ambrose J Huang; Niels Oesingmann; Qun Chen; Manmeen Kaur; Keyma Prince; Ting Song; Elissa L Kramer; Edward F Leonard
Journal:  Am J Physiol Renal Physiol       Date:  2007-01-09

Review 2.  Non-Cartesian parallel imaging reconstruction.

Authors:  Katherine L Wright; Jesse I Hamilton; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-10       Impact factor: 4.813

Review 3.  Measuring GFR: a systematic review.

Authors:  Inga Soveri; Ulla B Berg; Jonas Björk; Carl-Gustaf Elinder; Anders Grubb; Ingegerd Mejare; Gunnar Sterner; Sten-Erik Bäck
Journal:  Am J Kidney Dis       Date:  2014-05-17       Impact factor: 8.860

4.  Rapid multislice T1 mapping of mouse myocardium: Application to quantification of manganese uptake in α-Dystrobrevin knockout mice.

Authors:  Kai Jiang; Wen Li; Wei Li; Sen Jiao; Laurie Castel; David R Van Wagoner; Xin Yu
Journal:  Magn Reson Med       Date:  2014-11-18       Impact factor: 4.668

5.  Renal tubular events following passage from the supine to the standing position in patients with compensated liver cirrhosis: loss of tubuloglomerular feedback.

Authors:  G Sansoè; A M Biava; S Silvano; A Ferrari; F Rosina; A Smedile; A Touscoz; L Bonardi; M Rizzetto
Journal:  Gut       Date:  2002-11       Impact factor: 23.059

6.  Rapid T1 mapping of mouse myocardium with saturation recovery Look-Locker method.

Authors:  Wen Li; Mark Griswold; Xin Yu
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

7.  Noninvasive Assessment of Renal Fibrosis with Magnetization Transfer MR Imaging: Validation and Evaluation in Murine Renal Artery Stenosis.

Authors:  Kai Jiang; Christopher M Ferguson; Behzad Ebrahimi; Hui Tang; Timothy L Kline; Tyson A Burningham; Prassana K Mishra; Joseph P Grande; Slobodan I Macura; Lilach O Lerman
Journal:  Radiology       Date:  2016-10-03       Impact factor: 11.105

8.  MRI-measurement of perfusion and glomerular filtration in the human kidney with a separable compartment model.

Authors:  Steven P Sourbron; Henrik J Michaely; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Invest Radiol       Date:  2008-01       Impact factor: 6.016

9.  Dynamic contrast-enhanced quantitative susceptibility mapping with ultrashort echo time MRI for evaluating renal function.

Authors:  Luke Xie; Anita T Layton; Nian Wang; Peder E Z Larson; Jeff L Zhang; Vivian S Lee; Chunlei Liu; G Allan Johnson
Journal:  Am J Physiol Renal Physiol       Date:  2015-10-07

10.  Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 tesla: initial results.

Authors:  Frank G Zöllner; Daniel Schock-Kusch; Sandra Bäcker; Sabine Neudecker; Norbert Gretz; Lothar R Schad
Journal:  PLoS One       Date:  2013-11-18       Impact factor: 3.240

View more
  11 in total

1.  Measurement of murine kidney functional biomarkers using DCE-MRI: A multi-slice TRICKS technique and semi-automated image processing algorithm.

Authors:  Kai Jiang; Hui Tang; Prasanna K Mishra; Slobodan I Macura; Lilach O Lerman
Journal:  Magn Reson Imaging       Date:  2019-08-20       Impact factor: 2.546

2.  Photoacoustic Imaging of Nanoparticle Transport in the Kidneys at High Temporal Resolution.

Authors:  Xingya Jiang; Bujie Du; Shaoheng Tang; Jer-Tsong Hsieh; Jie Zheng
Journal:  Angew Chem Int Ed Engl       Date:  2019-03-27       Impact factor: 15.336

Review 3.  Noninvasive assessment of renal fibrosis by magnetic resonance imaging and ultrasound techniques.

Authors:  Kai Jiang; Christopher M Ferguson; Lilach O Lerman
Journal:  Transl Res       Date:  2019-04-22       Impact factor: 7.012

4.  Dynamic Contrast Enhancement (DCE) MRI-Derived Renal Perfusion and Filtration: Basic Concepts.

Authors:  Michael Pedersen; Pietro Irrera; Walter Dastrù; Frank G Zöllner; Kevin M Bennett; Scott C Beeman; G Larry Bretthorst; Joel R Garbow; Dario Livio Longo
Journal:  Methods Mol Biol       Date:  2021

5.  Reliable Assessment of Swine Renal Fibrosis Using Quantitative Magnetization Transfer Imaging.

Authors:  Kai Jiang; Christopher M Ferguson; Roger C Grimm; Xiangyang Zhu; James F Glockner; Lilach O Lerman
Journal:  Invest Radiol       Date:  2022-05-01       Impact factor: 6.016

6.  Selective kidney targeting increases the efficacy of mesenchymal stromal/stem cells for alleviation of murine stenotic-kidney senescence and damage.

Authors:  Seo Rin Kim; Kai Jiang; Xiaojun Chen; Amrutesh S Puranik; Xiang-Yang Zhu; Amir Lerman; Tamara Tchkonia; James L Kirkland; Lilach O Lerman
Journal:  J Tissue Eng Regen Med       Date:  2022-03-23       Impact factor: 4.323

7.  Multiparametric MRI detects longitudinal evolution of folic acid-induced nephropathy in mice.

Authors:  Kai Jiang; Tristan A Ponzo; Hui Tang; Prasanna K Mishra; Slobodan I Macura; Lilach O Lerman
Journal:  Am J Physiol Renal Physiol       Date:  2018-08-08

8.  Fast magnetic resonance fingerprinting for dynamic contrast-enhanced studies in mice.

Authors:  Yuning Gu; Charlie Y Wang; Christian E Anderson; Yuchi Liu; He Hu; Mette L Johansen; Dan Ma; Yun Jiang; Ciro Ramos-Estebanez; Susann Brady-Kalnay; Mark A Griswold; Chris A Flask; Xin Yu
Journal:  Magn Reson Med       Date:  2018-05-09       Impact factor: 4.668

9.  Quantitative Magnetization Transfer Detects Renal Fibrosis in Murine Kidneys With Renal Artery Stenosis.

Authors:  Kai Jiang; Yiyuan Fang; Christopher M Ferguson; Hui Tang; Prasanna K Mishra; Slobodan I Macura; Lilach O Lerman
Journal:  J Magn Reson Imaging       Date:  2020-09-17       Impact factor: 4.813

10.  Renovascular Disease Induces Senescence in Renal Scattered Tubular-Like Cells and Impairs Their Reparative Potency.

Authors:  Xiao-Jun Chen; Seo Rin Kim; Kai Jiang; Christopher M Ferguson; Hui Tang; Xiang-Yang Zhu; Amir Lerman; Alfonso Eirin; Lilach O Lerman
Journal:  Hypertension       Date:  2021-01-04       Impact factor: 10.190

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.