Literature DB >> 26447222

Dynamic contrast-enhanced quantitative susceptibility mapping with ultrashort echo time MRI for evaluating renal function.

Luke Xie1, Anita T Layton2, Nian Wang3, Peder E Z Larson4, Jeff L Zhang5, Vivian S Lee5, Chunlei Liu6, G Allan Johnson7.   

Abstract

Dynamic contrast-enhanced (DCE) MRI can provide key insight into renal function. DCE MRI is typically achieved through an injection of a gadolinium (Gd)-based contrast agent, which has desirable T1 quenching and tracer kinetics. However, significant T2* blooming effects and signal voids can arise when Gd becomes very concentrated, especially in the renal medulla and pelvis. One MRI sequence designed to alleviate T2* effects is the ultrashort echo time (UTE) sequence. In the present study, we observed T2* blooming in the inner medulla of the mouse kidney, despite using UTE at an echo time of 20 microseconds and a low dose of 0.03 mmol/kg Gd. We applied quantitative susceptibility mapping (QSM) and resolved the signal void into a positive susceptibility signal. The susceptibility values [in parts per million (ppm)] were converted into molar concentrations of Gd using a calibration curve. We determined the concentrating mechanism (referred to as the concentrating index) as a ratio of maximum Gd concentration in the inner medulla to the renal artery. The concentrating index was assessed longitudinally over a 17-wk course (3, 5, 7, 9, 13, 17 wk of age). We conclude that the UTE-based DCE method is limited in resolving extreme T2* content caused by the kidney's strong concentrating mechanism. QSM was able to resolve and confirm the source of the blooming effect to be the large positive susceptibility of concentrated Gd. UTE with QSM can complement traditional magnitude UTE and offer a powerful tool to study renal pathophysiology.
Copyright © 2016 the American Physiological Society.

Entities:  

Keywords:  3D dynamic contrast-enhanced; MR renography; gadolinium-based contrast agent; kidney concentrating mechanism; magnetic resonance imaging; quantitative susceptibility mapping; small animal preclinical imaging; ultrashort echo time

Mesh:

Substances:

Year:  2015        PMID: 26447222      PMCID: PMC4719043          DOI: 10.1152/ajprenal.00351.2015

Source DB:  PubMed          Journal:  Am J Physiol Renal Physiol        ISSN: 1522-1466


  57 in total

1.  T₁-weighted ultrashort echo time method for positive contrast imaging of magnetic nanoparticles and cancer cells bound with the targeted nanoparticles.

Authors:  Longjiang Zhang; Xiaodong Zhong; Liya Wang; Hongwei Chen; Y Andrew Wang; Julie Yeh; Lily Yang; Hui Mao
Journal:  J Magn Reson Imaging       Date:  2011-01       Impact factor: 4.813

2.  Investigations of the origin of phase differences seen with ultrashort TE imaging of short T2 meniscal tissue.

Authors:  Michael Carl; Jing-Tzyh Alan Chiang
Journal:  Magn Reson Med       Date:  2011-09-02       Impact factor: 4.668

3.  Integrated Laplacian-based phase unwrapping and background phase removal for quantitative susceptibility mapping.

Authors:  Wei Li; Alexandru V Avram; Bing Wu; Xue Xiao; Chunlei Liu
Journal:  NMR Biomed       Date:  2013-12-11       Impact factor: 4.044

4.  3D fiber tractography with susceptibility tensor imaging.

Authors:  Chunlei Liu; Wei Li; Bing Wu; Yi Jiang; G Allan Johnson
Journal:  Neuroimage       Date:  2011-08-16       Impact factor: 6.556

5.  Ventilation/perfusion imaging of the lung using ultra-short echo time (UTE) MRI in an animal model of pulmonary embolism.

Authors:  Osamu Togao; Yoshiharu Ohno; Ivan Dimitrov; Connie C Hsia; Masaya Takahashi
Journal:  J Magn Reson Imaging       Date:  2011-07-14       Impact factor: 4.813

6.  Quantitative susceptibility mapping of kidney inflammation and fibrosis in type 1 angiotensin receptor-deficient mice.

Authors:  Luke Xie; Matthew A Sparks; Wei Li; Yi Qi; Chunlei Liu; Thomas M Coffman; G Allan Johnson
Journal:  NMR Biomed       Date:  2013-10-24       Impact factor: 4.044

7.  A comparison of radial keyhole strategies for high spatial and temporal resolution 4D contrast-enhanced MRI in small animal tumor models.

Authors:  Ergys Subashi; Everett J Moding; Gary P Cofer; James R MacFall; David G Kirsch; Yi Qi; G Allan Johnson
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

Review 8.  Qualitative and quantitative ultrashort-TE MRI of cortical bone.

Authors:  Jiang Du; Graeme M Bydder
Journal:  NMR Biomed       Date:  2012-12-28       Impact factor: 4.044

9.  Dehydration parameters and standards for laboratory mice.

Authors:  Christine M Bekkevold; Kimberly L Robertson; Mary K Reinhard; August H Battles; Neil E Rowland
Journal:  J Am Assoc Lab Anim Sci       Date:  2013       Impact factor: 1.232

10.  High temporal resolution parametric MRI monitoring of the initial ischemia/reperfusion phase in experimental acute kidney injury.

Authors:  Andreas Pohlmann; Jan Hentschel; Mandy Fechner; Uwe Hoff; Gordana Bubalo; Karen Arakelyan; Kathleen Cantow; Erdmann Seeliger; Bert Flemming; Helmar Waiczies; Sonia Waiczies; Wolf-Hagen Schunck; Duska Dragun; Thoralf Niendorf
Journal:  PLoS One       Date:  2013-02-28       Impact factor: 3.240

View more
  11 in total

1.  Dynamic contrast-enhanced MRI promotes early detection of toxin-induced acute kidney injury.

Authors:  Jamie R Privratsky; Nian Wang; Yi Qi; Jiafa Ren; Benjamin T Morris; John C Hunting; G Allan Johnson; Steven D Crowley
Journal:  Am J Physiol Renal Physiol       Date:  2018-12-05

Review 2.  MRI tools for assessment of microstructure and nephron function of the kidney.

Authors:  Luke Xie; Kevin M Bennett; Chunlei Liu; G Allan Johnson; Jeff Lei Zhang; Vivian S Lee
Journal:  Am J Physiol Renal Physiol       Date:  2016-09-14

3.  Measurement of Murine Single-Kidney Glomerular Filtration Rate Using Dynamic Contrast-Enhanced MRI.

Authors:  Kai Jiang; Hui Tang; Prasanna K Mishra; Slobodan I Macura; Lilach O Lerman
Journal:  Magn Reson Med       Date:  2017-10-16       Impact factor: 4.668

4.  Novel contrast mixture achieves contrast resolution of human bladder wall suitable for T1 mapping: applications in interstitial cystitis and beyond.

Authors:  Pradeep Tyagi; Joseph Janicki; Chan-Hong Moon; Jonathan Kaufman; Christopher Chermansky
Journal:  Int Urol Nephrol       Date:  2018-02-01       Impact factor: 2.370

5.  High-resolution MRI of kidney microstructures at 7.05 T with an endo-colonic Wireless Amplified NMR detector.

Authors:  Xianchun Zeng; Shuangtao Ma; John M Kruger; Rongpin Wang; Xiaobo Tan; Chunqi Qian
Journal:  J Magn Reson       Date:  2019-04-25       Impact factor: 2.229

6.  Multicenter reproducibility of quantitative susceptibility mapping in a gadolinium phantom using MEDI+0 automatic zero referencing.

Authors:  Kofi Deh; Keigo Kawaji; Marjolein Bulk; Louise Van Der Weerd; Emelie Lind; Pascal Spincemaille; Kelly McCabe Gillen; Johan Van Auderkerke; Yi Wang; Thanh D Nguyen
Journal:  Magn Reson Med       Date:  2018-10-04       Impact factor: 4.668

7.  MRI gradient-echo phase contrast of the brain at ultra-short TE with off-resonance saturation.

Authors:  Hongjiang Wei; Peng Cao; Antje Bischof; Roland G Henry; Peder E Z Larson; Chunlei Liu
Journal:  Neuroimage       Date:  2018-03-29       Impact factor: 6.556

8.  MRI-Based Quantification of Magnetic Susceptibility in Gel Phantoms: Assessment of Measurement and Calculation Accuracy.

Authors:  Emma Olsson; Ronnie Wirestam; Emelie Lind
Journal:  Radiol Res Pract       Date:  2018-07-30

9.  Nephron number and its determinants: a 2020 update.

Authors:  Jennifer R Charlton; Edwin J Baldelomar; Dylan M Hyatt; Kevin M Bennett
Journal:  Pediatr Nephrol       Date:  2020-04-29       Impact factor: 3.714

10.  Exercise-induced calf muscle hyperemia: Rapid mapping of magnetic resonance imaging using deep learning approach.

Authors:  Jeff L Zhang; Christopher C Conlin; Xiaowan Li; Gwenael Layec; Ken Chang; Jayashree Kalpathy-Cramer; Vivian S Lee
Journal:  Physiol Rep       Date:  2020-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.