Literature DB >> 29033488

Automated Liver Elasticity Calculation for 3D MRE.

Bogdan Dzyubak1, Kevin J Glaser1, Armando Manduca1, Richard L Ehman1.   

Abstract

Magnetic Resonance Elastography (MRE) is a phase-contrast MRI technique which calculates quantitative stiffness images, called elastograms, by imaging the propagation of acoustic waves in tissues. It is used clinically to diagnose liver fibrosis. Automated analysis of MRE is difficult as the corresponding MRI magnitude images (which contain anatomical information) are affected by intensity inhomogeneity, motion artifact, and poor tissue- and edge-contrast. Additionally, areas with low wave amplitude must be excluded. An automated algorithm has already been successfully developed and validated for clinical 2D MRE. 3D MRE acquires substantially more data and, due to accelerated acquisition, has exacerbated image artifacts. Also, the current 3D MRE processing does not yield a confidence map to indicate MRE wave quality and guide ROI selection, as is the case in 2D. In this study, extension of the 2D automated method, with a simple wave-amplitude metric, was developed and validated against an expert reader in a set of 57 patient exams with both 2D and 3D MRE. The stiffness discrepancy with the expert for 3D MRE was -0.8% ± 9.45% and was better than discrepancy with the same reader for 2D MRE (-3.2% ± 10.43%), and better than the inter-reader discrepancy observed in previous studies. There were no automated processing failures in this dataset. Thus, the automated liver elasticity calculation (ALEC) algorithm is able to calculate stiffness from 3D MRE data with minimal bias and good precision, while enabling stiffness measurements to be fully reproducible and to be easily performed on the large 3D MRE datasets.

Entities:  

Keywords:  Automation; CAD; Elastography; Liver; MRE; ROI; Segmentation; Stiffness

Year:  2017        PMID: 29033488      PMCID: PMC5637392          DOI: 10.1117/12.2254476

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  9 in total

1.  Fast random walker with priors using precomputation for interactive medical image segmentation.

Authors:  Shawn Andrews; Ghassan Hamarneh; Ahmed Saad
Journal:  Med Image Comput Comput Assist Interv       Date:  2010

2.  Method to correct intensity inhomogeneity in MR images for atherosclerosis characterization.

Authors:  Olivier Salvado; Claudia Hillenbrand; Shaoxiang Zhang; David L Wilson
Journal:  IEEE Trans Med Imaging       Date:  2006-05       Impact factor: 10.048

3.  Magnetic resonance elastography by direct visualization of propagating acoustic strain waves.

Authors:  R Muthupillai; D J Lomas; P J Rossman; J F Greenleaf; A Manduca; R L Ehman
Journal:  Science       Date:  1995-09-29       Impact factor: 47.728

4.  An octahedral shear strain-based measure of SNR for 3D MR elastography.

Authors:  M D J McGarry; E E W Van Houten; P R Perriñez; A J Pattison; J B Weaver; K D Paulsen
Journal:  Phys Med Biol       Date:  2011-06-08       Impact factor: 3.609

Review 5.  Liver fibrosis.

Authors:  Ramón Bataller; David A Brenner
Journal:  J Clin Invest       Date:  2005-02       Impact factor: 14.808

6.  Automated liver stiffness measurements with magnetic resonance elastography.

Authors:  Bogdan Dzyubak; Kevin Glaser; Meng Yin; Jayant Talwalkar; Jun Chen; Armando Manduca; Richard L Ehman
Journal:  J Magn Reson Imaging       Date:  2012-12-19       Impact factor: 4.813

7.  Novel 3D Magnetic Resonance Elastography for the Noninvasive Diagnosis of Advanced Fibrosis in NAFLD: A Prospective Study.

Authors:  Rohit Loomba; Jeffrey Cui; Tanya Wolfson; William Haufe; Jonathan Hooker; Nikolaus Szeverenyi; Brandon Ang; Archana Bhatt; Kang Wang; Hamed Aryafar; Cindy Behling; Mark A Valasek; Grace Y Lin; Anthony Gamst; David A Brenner; Meng Yin; Kevin J Glaser; Richard L Ehman; Claude B Sirlin
Journal:  Am J Gastroenterol       Date:  2016-03-22       Impact factor: 10.864

Review 8.  Diagnostic performance of magnetic resonance elastography in staging liver fibrosis: a systematic review and meta-analysis of individual participant data.

Authors:  Siddharth Singh; Sudhakar K Venkatesh; Zhen Wang; Frank H Miller; Utaroh Motosugi; Russell N Low; Tarek Hassanein; Patrick Asbach; Edmund M Godfrey; Meng Yin; Jun Chen; Andrew P Keaveny; Mellena Bridges; Anneloes Bohte; Mohammad Hassan Murad; David J Lomas; Jayant A Talwalkar; Richard L Ehman
Journal:  Clin Gastroenterol Hepatol       Date:  2014-11-20       Impact factor: 11.382

9.  Automated liver elasticity calculation for MR elastography.

Authors:  Bogdan Dzyubak; Sudhakar K Venkatesh; Armando Manduca; Kevin J Glaser; Richard L Ehman
Journal:  J Magn Reson Imaging       Date:  2015-10-22       Impact factor: 4.813

  9 in total
  6 in total

Review 1.  MR elastography of liver: current status and future perspectives.

Authors:  Ilkay S Idilman; Jiahui Li; Meng Yin; Sudhakar K Venkatesh
Journal:  Abdom Radiol (NY)       Date:  2020-07-23

Review 2.  Advances in Magnetic Resonance Elastography of Liver.

Authors:  Jiahui Li; Sudhakar Kundapur Venkatesh; Meng Yin
Journal:  Magn Reson Imaging Clin N Am       Date:  2020-06-06       Impact factor: 2.266

3.  SPIE Computer-Aided Diagnosis conference anniversary review.

Authors:  Ronald M Summers; Maryellen L Giger
Journal:  J Med Imaging (Bellingham)       Date:  2022-05-19

4.  Shear wave speeds in nearly-incompressible fibrous materials with two fiber families.

Authors:  Zuoxian Hou; Philip V Bayly; Ruth J Okamoto
Journal:  J Acoust Soc Am       Date:  2021-02       Impact factor: 1.840

5.  Multiparametric Magnetic Resonance Elastography Improves the Detection of NASH Regression Following Bariatric Surgery.

Authors:  Alina M Allen; Vijay H Shah; Terry M Therneau; Sudhakar K Venkatesh; Taofic Mounajjed; Joseph J Larson; Kristin C Mara; Todd A Kellogg; Michael L Kendrick; Travis J McKenzie; Suzanne M Greiner; Jiahui Li; Kevin J Glaser; Michael L Wells; Timothy J Gunneson; Richard L Ehman; Meng Yin
Journal:  Hepatol Commun       Date:  2019-11-05

Review 6.  Multiparametric MR mapping in clinical decision-making for diffuse liver disease.

Authors:  Helena B Thomaides-Brears; Rita Lepe; Rajarshi Banerjee; Carlos Duncker
Journal:  Abdom Radiol (NY)       Date:  2020-08-05
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.