Rohit Loomba1,2,3, Jeffrey Cui2, Tanya Wolfson4, William Haufe5, Jonathan Hooker5, Nikolaus Szeverenyi5, Brandon Ang2, Archana Bhatt2, Kang Wang5, Hamed Aryafar6, Cindy Behling7, Mark A Valasek8, Grace Y Lin8, Anthony Gamst4, David A Brenner1, Meng Yin9, Kevin J Glaser9, Richard L Ehman9, Claude B Sirlin5. 1. Division of Gastroenterology, Department of Medicine, University of California at San Diego, La Jolla, California, USA. 2. NAFLD Research Center, Department of Medicine, University of California at San Diego, La Jolla, California, USA. 3. Division of Epidemiology, Department of Family and Preventive Medicine, University of California at San Diego, La Jolla, California, USA. 4. Department of Mathematics, University of California at San Diego, La Jolla, California, USA. 5. Liver Imaging Group, Department of Radiology, University of California at San Diego, La Jolla, California, USA. 6. Department of Radiology, University of California at San Diego, La Jolla, California, USA. 7. Department of Pathology, Sharp Health System, San Diego, California, USA. 8. Department of Pathology, University of California at San Diego, La Jolla, California, USA. 9. Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Abstract
OBJECTIVES: Recent studies show two-dimensional (2D)-magnetic resonance elastography (MRE) is accurate in diagnosing advanced fibrosis (stages 3 and 4) in nonalcoholic fatty liver disease (NAFLD) patients. Three-dimensional (3D)-MRE is a more advanced version of the technology that can image shear-wave fields in 3D of the entire liver. The aim of this study was to prospectively compare the diagnostic accuracy of 3D-MRE and 2D-MRE for diagnosing advanced fibrosis in patients with biopsy-proven NAFLD. METHODS: This cross-sectional analysis of a prospective study included 100 consecutive patients (56% women) with biopsy-proven NAFLD who also underwent MRE. Area under the receiver operating characteristic (AUROC) analysis was performed to assess the accuracy of 2D- and 3D-MRE in diagnosing advanced fibrosis. RESULTS: The mean (±s.d.) of age and body mass index were 50.2 (±13.6) years and 32.1 (±5.0) kg/m(2), respectively. The AUROC for diagnosing advanced fibrosis was 0.981 for 3D-MRE at 40 Hz, 0.927 for 3D-MRE at 60 Hz (standard shear-wave frequency), and 0.921 for 2D-MRE at 60 Hz (standard shear-wave frequency). At a threshold of 2.43 kPa, 3D-MRE at 40 Hz had sensitivity 1.0, specificity 0.94, positive predictive value 0.72, and negative predictive value 1.0 for diagnosing advanced fibrosis. 3D-MRE at 40 Hz had significantly higher AUROC (P<0.05) than 2D-MRE at 60 Hz for diagnosing advanced fibrosis. CONCLUSIONS: Utilizing a prospective study design, we demonstrate that 3D MRE at 40 Hz has the highest diagnostic accuracy in diagnosing NAFLD advanced fibrosis. Both 2D- and 3D-MRE at 60 Hz, the standard shear-wave frequency, are also highly accurate in diagnosing NAFLD advanced fibrosis.
OBJECTIVES: Recent studies show two-dimensional (2D)-magnetic resonance elastography (MRE) is accurate in diagnosing advanced fibrosis (stages 3 and 4) in nonalcoholic fatty liver disease (NAFLD) patients. Three-dimensional (3D)-MRE is a more advanced version of the technology that can image shear-wave fields in 3D of the entire liver. The aim of this study was to prospectively compare the diagnostic accuracy of 3D-MRE and 2D-MRE for diagnosing advanced fibrosis in patients with biopsy-proven NAFLD. METHODS: This cross-sectional analysis of a prospective study included 100 consecutive patients (56% women) with biopsy-proven NAFLD who also underwent MRE. Area under the receiver operating characteristic (AUROC) analysis was performed to assess the accuracy of 2D- and 3D-MRE in diagnosing advanced fibrosis. RESULTS: The mean (±s.d.) of age and body mass index were 50.2 (±13.6) years and 32.1 (±5.0) kg/m(2), respectively. The AUROC for diagnosing advanced fibrosis was 0.981 for 3D-MRE at 40 Hz, 0.927 for 3D-MRE at 60 Hz (standard shear-wave frequency), and 0.921 for 2D-MRE at 60 Hz (standard shear-wave frequency). At a threshold of 2.43 kPa, 3D-MRE at 40 Hz had sensitivity 1.0, specificity 0.94, positive predictive value 0.72, and negative predictive value 1.0 for diagnosing advanced fibrosis. 3D-MRE at 40 Hz had significantly higher AUROC (P<0.05) than 2D-MRE at 60 Hz for diagnosing advanced fibrosis. CONCLUSIONS: Utilizing a prospective study design, we demonstrate that 3D MRE at 40 Hz has the highest diagnostic accuracy in diagnosing NAFLD advanced fibrosis. Both 2D- and 3D-MRE at 60 Hz, the standard shear-wave frequency, are also highly accurate in diagnosing NAFLD advanced fibrosis.
Authors: Rohit Loomba; Nicholas Schork; Chi-Hua Chen; Ricki Bettencourt; Ana Bhatt; Brandon Ang; Phirum Nguyen; Carolyn Hernandez; Lisa Richards; Joanie Salotti; Steven Lin; Ekihiro Seki; Karen E Nelson; Claude B Sirlin; David Brenner Journal: Gastroenterology Date: 2015-08-20 Impact factor: 22.682
Authors: Laurent Huwart; Christine Sempoux; Eric Vicaut; Najat Salameh; Laurence Annet; Etienne Danse; Frank Peeters; Leon C ter Beek; Jacques Rahier; Ralph Sinkus; Yves Horsmans; Bernard E Van Beers Journal: Gastroenterology Date: 2008-04-04 Impact factor: 22.682
Authors: Rohit Loomba; Maria Abraham; Aynur Unalp; Laura Wilson; Joel Lavine; Ed Doo; Nathan M Bass Journal: Hepatology Date: 2012-07-26 Impact factor: 17.425
Authors: Mark L Palmeri; Michael H Wang; Ned C Rouze; Manal F Abdelmalek; Cynthia D Guy; Barry Moser; Anna Mae Diehl; Kathryn R Nightingale Journal: J Hepatol Date: 2011-01-21 Impact factor: 25.083
Authors: Indra Neil Guha; Julie Parkes; Paul Roderick; Dipanker Chattopadhyay; Richard Cross; Scott Harris; Philip Kaye; Alastair D Burt; Steve D Ryder; Guruprasad P Aithal; Christopher P Day; William M Rosenberg Journal: Hepatology Date: 2008-02 Impact factor: 17.425
Authors: Paul Angulo; Jason M Hui; Giulio Marchesini; Ellisabetta Bugianesi; Jacob George; Geoffrey C Farrell; Felicity Enders; Sushma Saksena; Alastair D Burt; John P Bida; Keith Lindor; Schuyler O Sanderson; Marco Lenzi; Leon A Adams; James Kench; Terry M Therneau; Christopher P Day Journal: Hepatology Date: 2007-04 Impact factor: 17.425
Authors: Rachel M Williamson; Jackie F Price; Stephen Glancy; Elisa Perry; Lisa D Nee; Peter C Hayes; Brian M Frier; Liesbeth A F Van Look; Geoffrey I Johnston; Rebecca M Reynolds; Mark W J Strachan Journal: Diabetes Care Date: 2011-04-08 Impact factor: 19.112