Literature DB >> 32705312

MR elastography of liver: current status and future perspectives.

Ilkay S Idilman1,2, Jiahui Li1, Meng Yin1, Sudhakar K Venkatesh3.   

Abstract

Non-invasive evaluation of liver fibrosis has evolved over the last couple of decades. Currently, elastography techniques are the most widely used non-invasive methods for clinical evaluation of chronic liver disease (CLD). MR elastography (MRE) of the liver has been used in the clinical practice for nearly a decade and continues to be widely accepted for detection and staging of liver fibrosis. With MRE, one can directly visualize propagating shear waves through the liver and an inversion algorithm in the scanner automatically converts the shear wave properties into an elastogram (stiffness map) on which liver stiffness can be calculated. The commonly used MRE method, two-dimensional gradient recalled echo (2D-GRE) sequence has produced excellent results in the evaluation of liver fibrosis in CLD from various etiologies and newer clinical indications continue to emerge. Advances in MRE technique, including 3D MRE, automated liver elasticity calculation, improvements in shear wave delivery and patient experience, are promising to provide a faster and more reliable MRE of liver. Innovations, including evaluation of mechanical parameters, such as loss modulus, displacement, and volumetric strain, are promising for comprehensive evaluation of CLD as well as understanding pathophysiology, and in differentiating various etiologies of CLD. In this review, the current status of the MRE of liver in CLD are outlined and followed by a brief description of advanced techniques and innovations in MRE of liver.

Entities:  

Keywords:  3D MRE; Damping ratio; Elasticity; Liver fibrosis; Viscosity; Volumetric strain

Mesh:

Year:  2020        PMID: 32705312      PMCID: PMC7954231          DOI: 10.1007/s00261-020-02656-7

Source DB:  PubMed          Journal:  Abdom Radiol (NY)


  134 in total

1.  Epidemiology of chronic liver diseases in the USA in the past three decades.

Authors:  Zobair M Younossi; Maria Stepanova; Youssef Younossi; Pegah Golabi; Alita Mishra; Nila Rafiq; Linda Henry
Journal:  Gut       Date:  2019-07-31       Impact factor: 23.059

2.  Repeatability of MR Elastography of Liver: A Meta-Analysis.

Authors:  Suraj D Serai; Nancy A Obuchowski; Sudhakar K Venkatesh; Claude B Sirlin; Frank H Miller; Edward Ashton; Patricia E Cole; Richard L Ehman
Journal:  Radiology       Date:  2017-05-22       Impact factor: 11.105

3.  Usefulness of MR elastography for detecting clinical progression of cirrhosis from child-pugh class A to B in patients with type C viral hepatitis.

Authors:  Tomohiro Takamura; Utaroh Motosugi; Shintaro Ichikawa; Katsuhiro Sano; Hiroyuki Morisaka; Tomoaki Ichikawa; Nobuyuki Enomoto; Hiroshi Onishi
Journal:  J Magn Reson Imaging       Date:  2016-02-29       Impact factor: 4.813

Review 4.  Comparison of gradient-recalled echo and spin-echo echo-planar imaging MR elastography in staging liver fibrosis: a meta-analysis.

Authors:  Yong Seek Kim; Yu Na Jang; Ji Soo Song
Journal:  Eur Radiol       Date:  2017-11-21       Impact factor: 5.315

5.  Non-invasive evaluation of liver fibrosis: a comparison of ultrasound-based transient elastography and MR elastography in patients with viral hepatitis B and C.

Authors:  Anneloes E Bohte; Annikki de Niet; Louis Jansen; Shandra Bipat; Aart J Nederveen; Joanne Verheij; Valeska Terpstra; Ralph Sinkus; Karin M J van Nieuwkerk; Rob J de Knegt; Bert C Baak; Peter L M Jansen; Henk W Reesink; Jaap Stoker
Journal:  Eur Radiol       Date:  2013-10-25       Impact factor: 5.315

6.  MRI Assessment of Treatment Response in HIV-associated NAFLD: A Randomized Trial of a Stearoyl-Coenzyme-A-Desaturase-1 Inhibitor (ARRIVE Trial).

Authors:  Veeral H Ajmera; Edward Cachay; Christian Ramers; Irine Vodkin; Shirin Bassirian; Seema Singh; Neeraj Mangla; Richele Bettencourt; Jeannette L Aldous; Daniel Park; Daniel Lee; Jennifer Blanchard; Adrija Mamidipalli; Andrew Boehringer; Saima Aslam; Olof Dahlqvist Leinhard; Lisa Richards; Claude Sirlin; Rohit Loomba
Journal:  Hepatology       Date:  2019-06-18       Impact factor: 17.425

7.  Liver Nodules after the Fontan Operation: Role of Magnetic Resonance Elastography.

Authors:  Joseph T Poterucha; Sudhakar K Venkatesh; Jennifer L Novak; Frank Cetta
Journal:  Tex Heart Inst J       Date:  2015-08-01

8.  Noninvasive prediction of portal pressure with MR elastography and DCE-MRI of the liver and spleen: Preliminary results.

Authors:  Mathilde Wagner; Stefanie Hectors; Octavia Bane; Sonja Gordic; Paul Kennedy; Cecilia Besa; Thomas D Schiano; Swan Thung; Aaron Fischman; Bachir Taouli
Journal:  J Magn Reson Imaging       Date:  2018-04-11       Impact factor: 4.813

9.  Comparison of Standard Breath-Held, Free-Breathing, and Compressed Sensing 2D Gradient-Recalled Echo MR Elastography Techniques for Evaluating Liver Stiffness.

Authors:  Cara E Morin; Jonathan R Dillman; Suraj D Serai; Andrew T Trout; Jean A Tkach; Hui Wang
Journal:  AJR Am J Roentgenol       Date:  2018-10-09       Impact factor: 3.959

10.  Non-Invasive Evaluation of Hepatic Fibrosis: The Diagnostic Performance of Magnetic Resonance Elastography in Patients with Viral Hepatitis B or C.

Authors:  Wen-Pei Wu; Chen-Te Chou; Ran-Chou Chen; Chih-Wei Lee; Kwo-Whei Lee; Hwa-Koon Wu
Journal:  PLoS One       Date:  2015-10-15       Impact factor: 3.240

View more
  11 in total

1.  A novel radiomics signature based on T2-weighted imaging accurately predicts hepatic inflammation in individuals with biopsy-proven nonalcoholic fatty liver disease: a derivation and independent validation study.

Authors:  Zhong-Wei Chen; Huan-Ming Xiao; Xinjian Ye; Kun Liu; Rafael S Rios; Kenneth I Zheng; Yi Jin; Giovanni Targher; Christopher D Byrne; Junping Shi; Zhihan Yan; Xiao-Ling Chi; Ming-Hua Zheng
Journal:  Hepatobiliary Surg Nutr       Date:  2022-04       Impact factor: 7.293

Review 2.  Liver fibrosis assessment: MR and US elastography.

Authors:  Arinc Ozturk; Michael C Olson; Anthony E Samir; Sudhakar K Venkatesh
Journal:  Abdom Radiol (NY)       Date:  2021-10-23

3.  Tomoelastography based on multifrequency MR elastography predicts liver function reserve in patients with hepatocellular carcinoma: a prospective study.

Authors:  Huimin Lin; Yihuan Wang; Jiahao Zhou; Yuchen Yang; Xinxin Xu; Di Ma; Yongjun Chen; Chunxue Yang; Ingolf Sack; Jing Guo; Ruokun Li; Fuhua Yan
Journal:  Insights Imaging       Date:  2022-06-03

Review 4.  Collaterals in portal hypertension: anatomy and clinical relevance.

Authors:  Hitoshi Maruyama; Shuichiro Shiina
Journal:  Quant Imaging Med Surg       Date:  2021-08

5.  Magnetic Resonance Elastography of the Liver: A Single-Institution Review of Cases Performed in a 5-Year Interval.

Authors:  Carlos Morillo-Hernandez; Roberta Catania; Philip J Grosse; Gideon Bollino; Amir A Borhani; Alessandro Furlan
Journal:  J Comput Assist Tomogr       Date:  2022 Jan-Feb 01       Impact factor: 1.826

Review 6.  Quantitative magnetic resonance imaging for chronic liver disease.

Authors:  Guilherme Moura Cunha; Patrick J Navin; Kathryn J Fowler; Sudhakar K Venkatesh; Richard L Ehman; Claude B Sirlin
Journal:  Br J Radiol       Date:  2021-02-26       Impact factor: 3.629

7.  Risk Prediction Model Based on Magnetic Resonance Elastography-Assessed Liver Stiffness for Predicting Posthepatectomy Liver Failure in Patients with Hepatocellular Carcinoma.

Authors:  Hyo Jung Cho; Young Hwan Ahn; Min Suh Sim; Jung Woo Eun; Soon Sun Kim; Bong Wan Kim; Jimi Huh; Jei Hee Lee; Jai Keun Kim; Buil Lee; Jae Youn Cheong; Bohyun Kim
Journal:  Gut Liver       Date:  2022-03-15       Impact factor: 4.519

8.  Free-breathing radial magnetic resonance elastography of the liver in children at 3 T: a pilot study.

Authors:  Sevgi Gokce Kafali; Tess Armstrong; Shu-Fu Shih; Grace J Kim; Joseph L Holtrop; Robert S Venick; Shahnaz Ghahremani; Bradley D Bolster; Claudia M Hillenbrand; Kara L Calkins; Holden H Wu
Journal:  Pediatr Radiol       Date:  2022-04-02

9.  Imaging features of COVID-19-associated secondary sclerosing cholangitis on magnetic resonance cholangiopancreatography: a retrospective analysis.

Authors:  Soleen Ghafoor; Manon Germann; Christoph Jüngst; Beat Müllhaupt; Cäcilia S Reiner; Daniel Stocker
Journal:  Insights Imaging       Date:  2022-08-08

10.  Using MR elastography to assess portal hypertension and response to beta-blockers in patients with cirrhosis.

Authors:  Karen Vagner Danielsen; Jens Dahlgaard Hove; Puria Nabilou; Meng Yin; Jun Chen; Mirabella Zhao; Thomas Kallemose; Ane Søgaard Teisner; Hartwig Roman Siebner; Richard L Ehman; Søren Møller; Flemming Bendtsen
Journal:  Liver Int       Date:  2021-06-16       Impact factor: 8.754

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.