Literature DB >> 29027100

CORR Insights®: Does the Risk of Rerevision Vary Between Porous Tantalum Cups and Other Cementless Designs After Revision Hip Arthroplasty?

Johan Kärrholm1.   

Abstract

Mesh:

Substances:

Year:  2017        PMID: 29027100      PMCID: PMC5670061          DOI: 10.1007/s11999-017-5472-9

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


× No keyword cloud information.
  14 in total

1.  Acetabular component revision using a porous tantalum biomaterial: a case series.

Authors:  Arthur L Malkani; Matthew R Price; Charles H Crawford; Dale L Baker
Journal:  J Arthroplasty       Date:  2008-09-26       Impact factor: 4.757

2.  Revision of failed total hip arthroplasty acetabular cups to porous tantalum components: a 5-year follow-up study.

Authors:  Mariano Fernández-Fairen; Antonio Murcia; Agustin Blanco; Antonio Meroño; Antonio Murcia; Jorge Ballester
Journal:  J Arthroplasty       Date:  2009-09-11       Impact factor: 4.757

3.  Trabecular metal used for major bone loss in acetabular hip revision.

Authors:  Jonah Hebert Davies; G Yves Laflamme; Josee Delisle; Julio Fernandes
Journal:  J Arthroplasty       Date:  2011-04-09       Impact factor: 4.757

4.  Is tantalum protective against infection in revision total hip arthroplasty?

Authors:  A T Tokarski; T A Novack; J Parvizi
Journal:  Bone Joint J       Date:  2015-01       Impact factor: 5.082

5.  Bacterial adherence to tantalum versus commonly used orthopedic metallic implant materials.

Authors:  Thomas A Schildhauer; Bruce Robie; Gert Muhr; Manfred Köller
Journal:  J Orthop Trauma       Date:  2006-07       Impact factor: 2.512

Review 6.  Eighty-six Percent Failure Rate of a Modular-Neck Femoral Stem Design at 3 to 5 Years: Lessons Learned.

Authors:  Derek T Bernstein; Morteza Meftah; Jaya Paranilam; Stephen J Incavo
Journal:  J Bone Joint Surg Am       Date:  2016-06-15       Impact factor: 5.284

7.  Combined trabecular metal acetabular shell and augment for acetabular revision with substantial bone loss: a mid-term review.

Authors:  M Abolghasemian; S Tangsataporn; A Sternheim; D Backstein; O Safir; A E Gross
Journal:  Bone Joint J       Date:  2013-02       Impact factor: 5.082

8.  Early femoral loosening of the titanium 3M capital cemented hip: A lesson relearned.

Authors:  A R Harvey; I W Barlow; N M P Clarke
Journal:  Hip Int       Date:  2002 Jan - Mar       Impact factor: 1.756

9.  Short-term survival of the trabecular metal cup is similar to that of standard cups used in acetabular revision surgery.

Authors:  Maziar Mohaddes; Ola Rolfson; Johan Kärrholm
Journal:  Acta Orthop       Date:  2014-11-17       Impact factor: 3.717

10.  The next critical role of orthopedic registries.

Authors:  Henrik Malchau; Stephen E Graves; Martyn Porter; William H Harris; Anders Troelsen
Journal:  Acta Orthop       Date:  2015-01-13       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.