Literature DB >> 25568412

Is tantalum protective against infection in revision total hip arthroplasty?

A T Tokarski1, T A Novack1, J Parvizi1.   

Abstract

We hypothesised that the use of tantalum (Ta) acetabular components in revision total hip arthroplasty (THA) was protective against subsequent failure due to infection. We identified 966 patients (421 men, 545 women and 990 hips) who had undergone revision THA between 2000 and 2013. The mean follow up was 40.2 months (3 months to 13.1 years). The mean age of the men and women was 62.3 years (31 to 90) and 65.1 years (25 to 92), respectively. Titanium (Ti) acetabular components were used in 536 hips while Ta components were used in 454 hips. In total, 73 (7.3%) hips experienced subsequent acetabular failure. The incidence of failure was lower in the Ta group at 4.4% (20/454) compared with 9.9% (53/536) in the Ti group (p < 0.001, odds ratio 2.38; 95% CI 1.37 to 4.27). Among the 144 hips (64 Ta, 80 Ti) for which revision had been performed because of infection, failure due to a subsequent infection was lower in the Ta group at 3.1% (2/64) compared with 17.5% (14/80) for the Ti group (p = 0.006). Thus, the use of Ta acetabular components during revision THA was associated with a lower incidence of failure from all causes and Ta components were associated with a lower incidence of subsequent infection when used in patients with periprosthetic joint infection. ©2015 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Hip; Arthroplasty; Tantalum

Mesh:

Substances:

Year:  2015        PMID: 25568412     DOI: 10.1302/0301-620X.97B1.34236

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  18 in total

1.  Do Trabecular Metal Acetabular Components Reduce the Risk of Rerevision After Revision THA Performed for Periprosthetic Joint Infection? A Study Using the NJR Data Set.

Authors:  Gulraj S Matharu; Andrew Judge; David W Murray; Hemant G Pandit
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

2.  Periprosthetic Joint Infection in Hip Arthroplasty: Is There an Association Between Infection and Bearing Surface Type?

Authors:  Rocco P Pitto; Laurent Sedel
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

3.  CORR Insights®: Does the Risk of Rerevision Vary Between Porous Tantalum Cups and Other Cementless Designs After Revision Hip Arthroplasty?

Authors:  Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2017-10-12       Impact factor: 4.176

Review 4.  The Impact of Incorporating Antimicrobials into Implant Surfaces.

Authors:  N J Hickok; I M Shapiro; A F Chen
Journal:  J Dent Res       Date:  2017-09-18       Impact factor: 6.116

5.  3D printing in experimental orthopaedic surgery: do it yourself.

Authors:  Irene I López-Torres; Pablo Sanz-Ruíz; Victor E León-Román; Federico Navarro-García; Rodrigo Priego-Sánchez; Javier Vaquero-Martín
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-03-12

6.  Does the Risk of Rerevision Vary Between Porous Tantalum Cups and Other Cementless Designs After Revision Hip Arthroplasty?

Authors:  Inari Laaksonen; Michelle Lorimer; Kirill Gromov; Ola Rolfson; Keijo T Mäkelä; Stephen E Graves; Henrik Malchau; Maziar Mohaddes
Journal:  Clin Orthop Relat Res       Date:  2017-06-23       Impact factor: 4.176

Review 7.  Tantalum Versus Titanium Acetabular Cups in Primary Total Hip Arthroplasty: Current Concept and a Review of the Current Literature.

Authors:  Rohit Rambani; Mayur Nayak; Miss Sheweidin Aziz; Krishan Almeida
Journal:  Arch Bone Jt Surg       Date:  2022-05

Review 8.  Role of Hip Arthroscopy in the Treatment of Avascular Necrosis of the Hip: A Systematic Review.

Authors:  Omid Shahpari; Javad Mortazavi; Mohammad H Ebrahimzadeh; Farshid Bagheri; Alireza Mousavian
Journal:  Arch Bone Jt Surg       Date:  2022-06

9.  Revision Total Hip Arthroplasty Using Tantalum Augment in Patients with Paprosky III or IV Acetabular Bone Defects: A Minimum 2-year Follow Up Study.

Authors:  Min Jeong; Hyung-Joo Kim; Seung-Jae Lim; Young-Wan Moon; Yoon-Soo Park
Journal:  Hip Pelvis       Date:  2016-06-30

Review 10.  Recent Advances in Research on Antibacterial Metals and Alloys as Implant Materials.

Authors:  Juyang Jiao; Shutao Zhang; Xinhua Qu; Bing Yue
Journal:  Front Cell Infect Microbiol       Date:  2021-07-02       Impact factor: 5.293

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.