Literature DB >> 28990683

The effect of unit, depth, and probe load on the reliability of muscle shear wave elastography: Variables affecting reliability of SWE.

Abdulrahman M Alfuraih1,2,3, Philip O'Connor3, Elizabeth Hensor2,3, Ai Lyn Tan2,3, Paul Emery2,3, Richard J Wakefield2,3.   

Abstract

PURPOSE: There is currently no standardized method for muscle shear wave elastography (SWE). The objective of this study was to investigate the effect of unit of measurement, depth, and probe load on the reliability of muscle SWE.
METHODS: The vastus lateralis, biceps femoris, biceps brachii, and abductor digiti minimi muscles were scanned on 20 healthy participants. The SWE readings were measured in shear wave velocity (m/s) and Young's modulus (kPa). Three acquisitions of varying depths were acquired from vastus lateralis. Minimal probe load was compared with the use of a standoff gel layer. Three repeated measurements were acquired to assess reliability using intraclass correlations (ICC).
RESULTS: The mean elasticity varied across muscle groups and ranged from 1.54 m/s for biceps femoris to 2.55 m/s for abductor digiti minimi (difference = 1.01 m/s [95% confidence interval, CI = 0.92, 1.10]). Reporting readings in meters per second resulted in higher ICC of 0.83 (0.65, 0.93) in comparison to 0.77 (0.52, 0.90) for kilopascal for the vastus lateralis muscle only. Variance increased proportionally with depth reaching 0.17 (equivalent to ±0.82 m/s) at 6 cm. Using a standoff gel decreased ICC to 0.63 (0.20, 0.84) despite similar mean elasticity readings to minimal probe load.
CONCLUSIONS: Different acquisition and technical factors may significantly affect the reliability of SWE in skeletal muscles. Readings acquired in the unit of shear wave velocity (m/s) from depths less than 4 cm using a minimal probe load without a standoff gel yielded the best reliability.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  elastography; muscles; reliability; ultrasound

Mesh:

Year:  2017        PMID: 28990683     DOI: 10.1002/jcu.22534

Source DB:  PubMed          Journal:  J Clin Ultrasound        ISSN: 0091-2751            Impact factor:   0.910


  30 in total

1.  Hamstring stiffness pattern during contraction in healthy individuals: analysis by ultrasound-based shear wave elastography.

Authors:  Bruno Mendes; Telmo Firmino; Raúl Oliveira; Tiago Neto; Jorge Infante; João R Vaz; Sandro R Freitas
Journal:  Eur J Appl Physiol       Date:  2018-08-14       Impact factor: 3.078

2.  High school male basketball athletes exhibit greater hamstring muscle stiffness than females as assessed with shear wave elastography.

Authors:  April L McPherson; Takashi Nagai; Nathan D Schilaty; Rena Hale; Timothy E Hewett; Nathaniel A Bates
Journal:  Skeletal Radiol       Date:  2020-03-03       Impact factor: 2.199

3.  Shear wave elastography characteristics of upper limb muscle in rigidity-dominant Parkinson's disease.

Authors:  Chang Wei Ding; Xin Song; Xin Yu Fu; Ying Chun Zhang; Pan Mao; Yu Jing Sheng; Min Yang; Cai Shan Wang; Ying Zhang; Xiao Fang Chen; Cheng Jie Mao; Wei Feng Luo; Chun Feng Liu
Journal:  Neurol Sci       Date:  2021-02-04       Impact factor: 3.307

4.  Evaluation of ulcerative colitis activity using transabdominal ultrasound shear wave elastography.

Authors:  Kenta Yamada; Takuya Ishikawa; Hiroki Kawashima; Eizaburo Ohno; Tadashi Iida; Eri Ishikawa; Yasuyuki Mizutani; Tsunaki Sawada; Keiko Maeda; Takeshi Yamamura; Naomi Kakushima; Kazuhiro Furukawa; Masanao Nakamura; Masatoshi Ishigami; Mitsuhiro Fujishiro
Journal:  Quant Imaging Med Surg       Date:  2022-01

5.  Full Characterization of in vivo Muscle as an Elastic, Incompressible, Transversely Isotropic Material Using Ultrasonic Rotational 3D Shear Wave Elasticity Imaging.

Authors:  Anna E Knight; Courtney A Trutna; Ned C Rouze; Lisa D Hobson-Webb; Annette Caenen; Felix Q Jin; Mark L Palmeri; Kathryn R Nightingale
Journal:  IEEE Trans Med Imaging       Date:  2021-12-30       Impact factor: 10.048

6.  Hip position influences shear wave elastography measurements of the hamstring muscles in healthy subjects.

Authors:  William A Berrigan; Jordan Wickstrom; Michael Farrell; Katharine Alter
Journal:  J Biomech       Date:  2020-07-11       Impact factor: 2.712

7.  Effect of acquisition depth and precompression from probe and couplant on shear wave elastography in soft tissue: an in vitro and in vivo study.

Authors:  Xiuming Wang; Yue Hu; Jia'an Zhu; Junxue Gao; Si Chen; Fang Liu; Wenxue Li; Yiqun Liu; Bilig Ariun
Journal:  Quant Imaging Med Surg       Date:  2020-03

8.  Objective Assessment of Regional Stiffness in Vastus Lateralis with Different Measurement Methods: A Reliability Study.

Authors:  Alfredo Bravo-Sánchez; Pablo Abián; Jorge Sánchez-Infante; Paula Esteban-Gacía; Fernando Jiménez; Javier Abián-Vicén
Journal:  Sensors (Basel)       Date:  2021-05-06       Impact factor: 3.576

9.  Ultrasound shear wave elastography and its association with rotator cuff tear characteristics.

Authors:  Rebekah L Lawrence; Matthew C Ruder; Vasilios Moutzouros; Eric C Makhni; Stephanie J Muh; Daniel Siegal; Steven B Soliman; Marnix van Holsbeeck; Michael J Bey
Journal:  JSES Int       Date:  2021-01-27

10.  SWE and SMI ultrasound techniques for monitoring needling treatment of ankylosing spondylitis: study protocol for a single-blinded randomized controlled trial.

Authors:  Mengyu Wang; Wen Fu; Lingcui Meng; Jia Liu; Lihua Wu; Yingjun Peng; Ziping Li
Journal:  Trials       Date:  2021-06-07       Impact factor: 2.279

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.