Jeffrey N Stout1, Elfar Adalsteinsson1,2, Bruce R Rosen3,4, Divya S Bolar2,3,5. 1. Harvard-MIT Health Sciences and Technology, Institute of Medical Engineering & Science, MIT, Cambridge, Massachusetts, USA. 2. Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA. 3. Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Massachusetts, USA. 4. Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA. 5. Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.
Abstract
PURPOSE: QUantitative Imaging of eXtraction of Oxygen and TIssue Consumption (QUIXOTIC) is a recent technique that measures voxel-wise oxygen extraction fraction (OEF) but suffers from long scan times, limiting its application. We implemented multiecho QUIXOTIC dubbed turbo QUIXOTIC (tQUIXOTIC) that reduces scan time eightfold and then applied it in functional MRI. METHODS: tQUIXOTIC utilizes a novel turbo gradient spin echo readout enabling measurement of venular blood transverse relaxation rate in a single tag-control acquisition. Using tQUIXOTIC, we estimated cortical gray matter (GM) OEF, created voxel-by-voxel GM OEF maps, and quantified changes in visual cortex OEF during a blocked design flashing checkerboard visual stimulus. Contamination from cerebrospinal fluid partial volume averaging was estimated and corrected. RESULTS: The average cortical GM OEF was estimated as 0.38 ± 0.06 (n = 8) using a 3.4-min acquisition. The average OEF in the visual cortex was estimated as 0.43 ± 0.04 at baseline and 0.35 ± 0.05 during activation, with an average %ΔOEF of -20%. These values are consistent with those of past studies. CONCLUSION: tQUIXOTIC successfully estimated cortical GM OEF in clinical scan times and detected changes in OEF during blocked design visual stimulation. tQUIXOTIC will be useful to monitor regional OEF clinically and in blocked design or event-related functional MRI experiments. Magn Reson Med 79:2713-2723, 2018.
PURPOSE: QUantitative Imaging of eXtraction of Oxygen and TIssue Consumption (QUIXOTIC) is a recent technique that measures voxel-wise oxygen extraction fraction (OEF) but suffers from long scan times, limiting its application. We implemented multiecho QUIXOTIC dubbed turbo QUIXOTIC (tQUIXOTIC) that reduces scan time eightfold and then applied it in functional MRI. METHODS: tQUIXOTIC utilizes a novel turbo gradient spin echo readout enabling measurement of venular blood transverse relaxation rate in a single tag-control acquisition. Using tQUIXOTIC, we estimated cortical gray matter (GM) OEF, created voxel-by-voxel GM OEF maps, and quantified changes in visual cortex OEF during a blocked design flashing checkerboard visual stimulus. Contamination from cerebrospinal fluid partial volume averaging was estimated and corrected. RESULTS: The average cortical GM OEF was estimated as 0.38 ± 0.06 (n = 8) using a 3.4-min acquisition. The average OEF in the visual cortex was estimated as 0.43 ± 0.04 at baseline and 0.35 ± 0.05 during activation, with an average %ΔOEF of -20%. These values are consistent with those of past studies. CONCLUSION: tQUIXOTIC successfully estimated cortical GM OEF in clinical scan times and detected changes in OEF during blocked design visual stimulation. tQUIXOTIC will be useful to monitor regional OEF clinically and in blocked design or event-related functional MRI experiments. Magn Reson Med 79:2713-2723, 2018.
Authors: Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase Journal: Magn Reson Med Date: 2002-06 Impact factor: 4.668
Authors: Manus J Donahue; Hanzhang Lu; Craig K Jones; Richard A E Edden; James J Pekar; Peter C M van Zijl Journal: Magn Reson Med Date: 2006-12 Impact factor: 4.668
Authors: Audrey P Fan; Andreas Schäfer; Laurentius Huber; Leonie Lampe; Steffen von Smuda; Harald E Möller; Arno Villringer; Claudine J Gauthier Journal: Neuroimage Date: 2015-11-05 Impact factor: 6.556
Authors: Mark Jenkinson; Christian F Beckmann; Timothy E J Behrens; Mark W Woolrich; Stephen M Smith Journal: Neuroimage Date: 2011-09-16 Impact factor: 6.556
Authors: Esra Abaci Turk; Jeffrey N Stout; Christopher Ha; Jie Luo; Borjan Gagoski; Filiz Yetisir; Polina Golland; Lawrence L Wald; Elfar Adalsteinsson; Julian N Robinson; Drucilla J Roberts; William H Barth; P Ellen Grant Journal: Top Magn Reson Imaging Date: 2019-10
Authors: Qin Qin; David C Alsop; Divya S Bolar; Luis Hernandez-Garcia; James Meakin; Dapeng Liu; Krishna S Nayak; Sophie Schmid; Matthias J P van Osch; Eric C Wong; Joseph G Woods; Greg Zaharchuk; Moss Y Zhao; Zungho Zun; Jia Guo Journal: Magn Reson Med Date: 2022-07-12 Impact factor: 3.737