Theoretical and experimental investigation of the VASO contrast mechanism.

Manus J Donahue1, Hanzhang Lu, Craig K Jones, Richard A E Edden, James J Pekar, Peter C M van Zijl.   

Abstract

Vascular space occupancy (VASO)-dependent functional MRI (fMRI) is a blood-nulling technique capable of generating microvascular cerebral blood volume (CBV)-weighted images. It is shown that at high magnetic field (3.0T) and high spatial resolution (1.89 x 1.89 x 3 mm(3)), the VASO signal changes are too large (6-7%) to originate from CBV effects alone. Additional contributions are investigated theoretically and experimentally as a function of MRI parameters (TR and TE), as well as the signal-to-noise ratio, (SNR) and spatial resolution. First, it is found that an arterial spin labeling (ASL) contribution causes large negative VASO signal changes at short TR. Second, even at high fMRI spatial resolution, CSF volume contributions (7-13%) cause VASO signal changes to become more negative, most noticeably at long TR and TE. Third, white matter (WM) effects reduce signal changes at lower spatial resolution. The VASO technique has been tested using different stimulus paradigms and field strengths (1-3), giving results consistent with comparable tasks investigated using BOLD and cerebral blood flow (CBF)-based techniques. Finally, simulations show that a mixture of fresh and steady-state blood may significantly alter signal changes at short TR (< or =3 s), permitting larger VASO signal changes than expected under pure steady-state conditions. Thus, many competing effects contribute to VASO contrast and care should be taken during interpretation.

Entities:  

Mesh:

Year:  2006        PMID: 17075857     DOI: 10.1002/mrm.21072

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  66 in total

1.  Automated brain tissue segmentation based on fractional signal mapping from inversion recovery Look-Locker acquisition.

Authors:  Wanyong Shin; Xiujuan Geng; Hong Gu; Wang Zhan; Qihong Zou; Yihong Yang
Journal:  Neuroimage       Date:  2010-05-07       Impact factor: 6.556

2.  Quantification of arterial cerebral blood volume using multiphase-balanced SSFP-based ASL.

Authors:  Lirong Yan; Cheng Li; Emily Kilroy; Felix W Wehrli; Danny J J Wang
Journal:  Magn Reson Med       Date:  2011-11-29       Impact factor: 4.668

3.  Application of whole-brain CBV-weighted fMRI to a cognitive stimulation paradigm: robust activation detection in a stroop task experiment using 3D GRASE VASO.

Authors:  Benedikt A Poser; David G Norris
Journal:  Hum Brain Mapp       Date:  2010-06-24       Impact factor: 5.038

4.  Three-dimensional acquisition of cerebral blood volume and flow responses during functional stimulation in a single scan.

Authors:  Ying Cheng; Peter C M van Zijl; James J Pekar; Jun Hua
Journal:  Neuroimage       Date:  2014-08-23       Impact factor: 6.556

Review 5.  IRON fMRI measurements of CBV and implications for BOLD signal.

Authors:  Joseph B Mandeville
Journal:  Neuroimage       Date:  2012-01-16       Impact factor: 6.556

6.  Change of the cerebrospinal fluid volume during brain activation investigated by T(1rho)-weighted fMRI.

Authors:  Tao Jin; Seong-Gi Kim
Journal:  Neuroimage       Date:  2010-03-22       Impact factor: 6.556

7.  Multi-parametric neuroimaging reproducibility: a 3-T resource study.

Authors:  Bennett A Landman; Alan J Huang; Aliya Gifford; Deepti S Vikram; Issel Anne L Lim; Jonathan A D Farrell; John A Bogovic; Jun Hua; Min Chen; Samson Jarso; Seth A Smith; Suresh Joel; Susumu Mori; James J Pekar; Peter B Barker; Jerry L Prince; Peter C M van Zijl
Journal:  Neuroimage       Date:  2010-11-20       Impact factor: 6.556

8.  Applications and limitations of whole-brain MAGIC VASO functional imaging.

Authors:  A Scouten; R T Constable
Journal:  Magn Reson Med       Date:  2007-08       Impact factor: 4.668

9.  Evaluation of MRI models in the measurement of CMRO2 and its relationship with CBF.

Authors:  Ai-Ling Lin; Peter T Fox; Yihong Yang; Hanzhang Lu; Li-Hai Tan; Jia-Hong Gao
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

Review 10.  Noise concerns and post-processing procedures in cerebral blood flow (CBF) and cerebral blood volume (CBV) functional magnetic resonance imaging.

Authors:  Manus J Donahue; Meher R Juttukonda; Jennifer M Watchmaker
Journal:  Neuroimage       Date:  2016-09-11       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.