Literature DB >> 28978547

Validation of the doubly labeled water method using off-axis integrated cavity output spectroscopy and isotope ratio mass spectrometry.

Edward L Melanson1,2, Tracy Swibas1, Wendy M Kohrt1,2, Vicki A Catenacci1, Seth A Creasy1, Guy Plasqui3, Loek Wouters3, John R Speakman4,5, Elena S F Berman6.   

Abstract

When the doubly labeled water (DLW) method is used to measure total daily energy expenditure (TDEE), isotope measurements are typically performed using isotope ratio mass spectrometry (IRMS). New technologies, such as off-axis integrated cavity output spectroscopy (OA-ICOS) provide comparable isotopic measurements of standard waters and human urine samples, but the accuracy of carbon dioxide production (V̇co2) determined with OA-ICOS has not been demonstrated. We compared simultaneous measurement V̇co2 obtained using whole-room indirect calorimetry (IC) with DLW-based measurements from IRMS and OA-ICOS. Seventeen subjects (10 female; 22 to 63 yr) were studied for 7 consecutive days in the IC. Subjects consumed a dose of 0.25 g H218O (98% APE) and 0.14 g 2H2O (99.8% APE) per kilogram of total body water, and urine samples were obtained on days 1 and 8 to measure average daily V̇co2 using OA-ICOS and IRMS. V̇co2 was calculated using both the plateau and intercept methods. There were no differences in V̇co2 measured by OA-ICOS or IRMS compared with IC when the plateau method was used. When the intercept method was used, V̇co2 using OA-ICOS did not differ from IC, but V̇co2 measured using IRMS was significantly lower than IC. Accuracy (~1-5%), precision (~8%), intraclass correlation coefficients ( R = 0.87-90), and root mean squared error (30-40 liters/day) of V̇co2 measured by OA-ICOS and IRMS were similar. Both OA-ICOS and IRMS produced measurements of V̇co2 with comparable accuracy and precision compared with IC.

Entities:  

Keywords:  adult; deuterium; humans; oxygen isotope; respiratory gas exchange

Mesh:

Substances:

Year:  2017        PMID: 28978547      PMCID: PMC5866416          DOI: 10.1152/ajpendo.00241.2017

Source DB:  PubMed          Journal:  Am J Physiol Endocrinol Metab        ISSN: 0193-1849            Impact factor:   4.310


  22 in total

1.  Measurement of total carbon dioxide production by means of D2O18.

Authors:  N LIFSON; G B GORDON; R McCLINTOCK
Journal:  J Appl Physiol       Date:  1955-05       Impact factor: 3.531

2.  Measurement of basal and total metabolism in hereditarily obese-hyperglycemic mice.

Authors:  R McCLINTOCK; N LIFSON
Journal:  Am J Physiol       Date:  1958-06

3.  Comparison of doubly labeled water with respirometry at low- and high-activity levels.

Authors:  K R Westerterp; F Brouns; W H Saris; F ten Hoor
Journal:  J Appl Physiol (1985)       Date:  1988-07

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Isotope method for the measurement of carbon dioxide production rate in man.

Authors:  W A Coward; A M Prentice
Journal:  Am J Clin Nutr       Date:  1985-03       Impact factor: 7.045

6.  Theory of use of the turnover rates of body water for measuring energy and material balance.

Authors:  N Lifson
Journal:  J Theor Biol       Date:  1966-09       Impact factor: 2.691

7.  Validity of the doubly labeled water method for estimating CO2 production in mice under different nutritional conditions.

Authors:  Stefano Guidotti; Harro A J Meijer; Gertjan van Dijk
Journal:  Am J Physiol Endocrinol Metab       Date:  2013-05-28       Impact factor: 4.310

8.  Direct analysis of δ2H and δ18O in natural and enriched human urine using laser-based, off-axis integrated cavity output spectroscopy.

Authors:  Elena S F Berman; Susan L Fortson; Steven P Snaith; Manish Gupta; Douglas S Baer; Isabelle Chery; Stephane Blanc; Edward L Melanson; Peter J Thomson; John R Speakman
Journal:  Anal Chem       Date:  2012-11-01       Impact factor: 6.986

9.  Comparison of short term indirect calorimetry and doubly labeled water method for the assessment of energy expenditure in preterm infants.

Authors:  K R Westerterp; H N Lafeber; E J Sulkers; P J Sauer
Journal:  Biol Neonate       Date:  1991

10.  Measurement of δ18O, δ17O, and 17O-excess in water by off-axis integrated cavity output spectroscopy and isotope ratio mass spectrometry.

Authors:  Elena S F Berman; Naomi E Levin; Amaelle Landais; Shuning Li; Thomas Owano
Journal:  Anal Chem       Date:  2013-10-14       Impact factor: 6.986

View more
  6 in total

1.  Accuracy and Practical Considerations for Doubly Labeled Water Analysis in Nutrition Studies Using a Laser-Based Isotope Instrument (Off-Axis Integrated Cavity Output Spectroscopy).

Authors:  Linda M Reynard; William W Wong; Noreen Tuross
Journal:  J Nutr       Date:  2022-01-11       Impact factor: 4.687

2.  Validity of Wrist-Wearable Activity Devices for Estimating Physical Activity in Adolescents: Comparative Study.

Authors:  Yingying Hao; Xiao-Kai Ma; Zheng Zhu; Zhen-Bo Cao
Journal:  JMIR Mhealth Uhealth       Date:  2021-01-07       Impact factor: 4.773

3.  A standard calculation methodology for human doubly labeled water studies.

Authors:  John R Speakman; Yosuke Yamada; Hiroyuki Sagayama; Elena S F Berman; Philip N Ainslie; Lene F Andersen; Liam J Anderson; Lenore Arab; Issaad Baddou; Kweku Bedu-Addo; Ellen E Blaak; Stephane Blanc; Alberto G Bonomi; Carlijn V C Bouten; Pascal Bovet; Maciej S Buchowski; Nancy F Butte; Stefan G J A Camps; Graeme L Close; Jamie A Cooper; Seth A Creasy; Sai Krupa Das; Richard Cooper; Lara R Dugas; Cara B Ebbeling; Ulf Ekelund; Sonja Entringer; Terrence Forrester; Barry W Fudge; Annelies H Goris; Michael Gurven; Catherine Hambly; Asmaa El Hamdouchi; Marije B Hoos; Sumei Hu; Noorjehan Joonas; Annemiek M Joosen; Peter Katzmarzyk; Kitty P Kempen; Misaka Kimura; William E Kraus; Robert F Kushner; Estelle V Lambert; William R Leonard; Nader Lessan; David S Ludwig; Corby K Martin; Anine C Medin; Erwin P Meijer; James C Morehen; James P Morton; Marian L Neuhouser; Theresa A Nicklas; Robert M Ojiambo; Kirsi H Pietiläinen; Yannis P Pitsiladis; Jacob Plange-Rhule; Guy Plasqui; Ross L Prentice; Roberto A Rabinovich; Susan B Racette; David A Raichlen; Eric Ravussin; Rebecca M Reynolds; Susan B Roberts; Albertine J Schuit; Anders M Sjödin; Eric Stice; Samuel S Urlacher; Giulio Valenti; Ludo M Van Etten; Edgar A Van Mil; Jonathan C K Wells; George Wilson; Brian M Wood; Jack Yanovski; Tsukasa Yoshida; Xueying Zhang; Alexia J Murphy-Alford; Cornelia U Loechl; Edward L Melanson; Amy H Luke; Herman Pontzer; Jennifer Rood; Dale A Schoeller; Klaas R Westerterp; William W Wong
Journal:  Cell Rep Med       Date:  2021-02-16

4.  Effect of Morning and Evening Exercise on Energy Balance: A Pilot Study.

Authors:  Seth A Creasy; Liza Wayland; Shelby L Panter; Sarah A Purcell; Rebecca Rosenberg; Erik A Willis; Bethelhem Shiferaw; Laura Grau; Matthew J Breit; Daniel H Bessesen; Edward L Melanson; Victoria A Catenacci
Journal:  Nutrients       Date:  2022-02-15       Impact factor: 5.717

5.  First use of triply labelled water analysis for energy expenditure measurements in mice.

Authors:  Xing Wang; Dehuang Kong; Gertjan van Dijk; Harro A J Meijer
Journal:  Sci Rep       Date:  2022-04-15       Impact factor: 4.379

6.  Validating accelerometry-derived proxies of energy expenditure using the doubly labelled water method in the smallest penguin species.

Authors:  G J Sutton; J A Botha; J R Speakman; J P Y Arnould
Journal:  Biol Open       Date:  2021-04-01       Impact factor: 2.422

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.