Literature DB >> 28948399

Interventional magnetic resonance imaging guided carotid embolectomy using a novel resonant marker catheter: demonstration of preclinical feasibility.

Jeffrey K Yang1, Andre M Cote1, Caroline D Jordan1, Sravani Kondapavulur, Aaron D Losey1, David McCoy1, Andrew Chu2, Jay F Yu1, Teri Moore1, Carol Stillson1, Fabio Settecase1, Matthew D Alexander1, Andrew Nicholson1, Daniel L Cooke1, Maythem Saeed1, Dave Barry2, Alastair J Martin1, Mark W Wilson1, Steven W Hetts3.   

Abstract

To assess the visualization and efficacy of a wireless resonant circuit (wRC) catheter system for carotid artery occlusion and embolectomy under real-time MRI guidance in vivo, and to compare MR imaging modality with x-ray for analysis of qualitative physiological measures of blood flow at baseline and after embolectomy. The wRC catheter system was constructed using a MR compatible PEEK fiber braided catheter (Penumbra, Inc, Alameda, CA) with a single insulated longitudinal copper loop soldered to a printed circuit board embedded within the catheter wall. In concordance with IACUC protocol (AN103047), in vivo carotid artery navigation and embolectomy were performed in four farm pigs (40-45 kg) under real-time MRI at 1.5T. Industry standard clots were introduced in incremental amounts until adequate arterial occlusion was noted in a total of n=13 arteries. Baseline vasculature and restoration of blood flow were confirmed via MR and x-ray imaging, and graded by the Thrombolysis in Cerebral Infarction (TICI) scale. Wilcoxon signed-rank tests were used to analyze differences in recanalization status between DSA and MRA imaging. Successful recanalizations (TICI 2b/3) were compared to clinical rates reported in literature via binomial tests. The wRC catheter system was visible both on 5° sagittal bSSFP and coronal GRE sequence. Successful recanalization was demonstrated in 11 of 13 occluded arteries by DSA analysis and 8 of 13 by MRA. Recanalization rates based on DSA (0.85) and MRA (0.62) were not significantly different from the clinical rate of mechanical aspiration thrombectomy reported in literature. Lastly, a Wilcoxon signed rank test indicated no significant difference between TICI scores analyzed by DSA and MRA. With demonstrated compatibility and visualization under MRI, the wRC catheter system is effective for in vivo endovascular embolectomy, suggesting progress towards clinical endovascular interventional MRI.

Entities:  

Keywords:  Embolectomy; Interventional MRI; Stroke; Wireless resonant marker

Mesh:

Year:  2017        PMID: 28948399      PMCID: PMC5896013          DOI: 10.1007/s10544-017-0225-9

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  37 in total

Review 1.  Endovascular interventional MRI.

Authors:  Christine B Henk; Charles B Higgins; Maythem Saeed
Journal:  J Magn Reson Imaging       Date:  2005-10       Impact factor: 4.813

2.  Resonant marker design and fabrication techniques for device visualization during interventional magnetic resonance imaging.

Authors:  Mandy Kaiser; Markus Detert; Martin A Rube; Abubakr El-Tahir; Ole Jakob Elle; Andreas Melzer; Bertram Schmidt; Georg H Rose
Journal:  Biomed Tech (Berl)       Date:  2015-04       Impact factor: 1.411

3.  A dedicated animal model for mechanical thrombectomy in acute stroke.

Authors:  J Gralla; G Schroth; L Remonda; A Fleischmann; J Fandino; J Slotboom; C Brekenfeld
Journal:  AJNR Am J Neuroradiol       Date:  2006 Jun-Jul       Impact factor: 3.825

4.  Carotid stent delivery in an XMR suite: immediate assessment of the physiologic impact of extracranial revascularization.

Authors:  Alastair J Martin; David A Saloner; Timothy P L Roberts; Heidi Roberts; Oliver M Weber; William Dillon; Sean Cullen; Van Halbach; Christopher F Dowd; Randall T Higashida
Journal:  AJNR Am J Neuroradiol       Date:  2005-03       Impact factor: 3.825

5.  Stent-retriever thrombectomy after intravenous t-PA vs. t-PA alone in stroke.

Authors:  Jeffrey L Saver; Mayank Goyal; Alain Bonafe; Hans-Christoph Diener; Elad I Levy; Vitor M Pereira; Gregory W Albers; Christophe Cognard; David J Cohen; Werner Hacke; Olav Jansen; Tudor G Jovin; Heinrich P Mattle; Raul G Nogueira; Adnan H Siddiqui; Dileep R Yavagal; Blaise W Baxter; Thomas G Devlin; Demetrius K Lopes; Vivek K Reddy; Richard du Mesnil de Rochemont; Oliver C Singer; Reza Jahan
Journal:  N Engl J Med       Date:  2015-04-17       Impact factor: 91.245

6.  Mechanical characterization of thromboemboli in acute ischemic stroke and laboratory embolus analogs.

Authors:  J Y Chueh; A K Wakhloo; G H Hendricks; C F Silva; J P Weaver; M J Gounis
Journal:  AJNR Am J Neuroradiol       Date:  2011-05-19       Impact factor: 3.825

7.  Catheter visualization with resonant markers at MR imaging-guided deployment of endovascular stents in swine.

Authors:  Titus Kuehne; Steffen Weiss; Florian Brinkert; Jochen Weil; Sevim Yilmaz; Boris Schmitt; Peter Ewert; Peter Lange; Matthias Gutberlet
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

8.  New method of thrombus preparation using a fluid model for evaluation of thrombectomy devices in a swine model.

Authors:  Qiuji Shao; Liangfu Zhu; Tianxiao Li; Li Li; Dujuan Li; Jiaqiang Zhang; Wei Ren; Liheng Wu
Journal:  Thromb Res       Date:  2014-08-22       Impact factor: 3.944

9.  Endovascular external carotid artery occlusion for brain selective targeting: a cerebrovascular swine model.

Authors:  Sundeep Mangla; Jae H Choi; Frank C Barone; Carol Novotney; Jenny Libien; Erwin Lin; John Pile-Spellman
Journal:  BMC Res Notes       Date:  2015-12-21

10.  Limitations of using synthetic blood clots for measuring in vitro clot capture efficiency of inferior vena cava filters.

Authors:  Ronald A Robinson; Luke H Herbertson; Srilekha Sarkar Das; Richard A Malinauskas; William F Pritchard; Laurence W Grossman
Journal:  Med Devices (Auckl)       Date:  2013-05-10
View more
  4 in total

1.  Wireless Resonant Circuits Printed Using Aerosol Jet Deposition for MRI Catheter Tracking.

Authors:  Caroline D Jordan; Bradford R H Thorne; Arjun Wadhwa; Aaron D Losey; Eugene Ozhinsky; Sravani Kondapavulur; Vincent Fratello; Teri Moore; Carol Stillson; Colin Yee; Ronald D Watkins; Greig C Scott; Alastair J Martin; Xiaoliang Zhang; Mark W Wilson; Steven W Hetts
Journal:  IEEE Trans Biomed Eng       Date:  2019-06-21       Impact factor: 4.538

2.  Diving into a Shallow Pool: Endovascular Treatment for Basilar Artery Occlusion.

Authors:  Steven W Hetts
Journal:  Radiology       Date:  2019-03-26       Impact factor: 29.146

3.  Combined Use of X-ray Angiography and Intraprocedural MRI Enables Tissue-based Decision Making Regarding Revascularization during Acute Ischemic Stroke Intervention.

Authors:  Kazim H Narsinh; Bridget F Kilbride; Kerstin Mueller; Daniel Murph; Alexander Copelan; Jonathan Massachi; Jeffrey Vitt; Chung-Huan Sun; Himanshu Bhat; Matthew R Amans; Christopher F Dowd; Van V Halbach; Randall T Higashida; Terilyn Moore; Mark W Wilson; Daniel L Cooke; Steven W Hetts
Journal:  Radiology       Date:  2021-02-09       Impact factor: 11.105

Review 4.  Relevance of Porcine Stroke Models to Bridge the Gap from Pre-Clinical Findings to Clinical Implementation.

Authors:  Marc Melià-Sorolla; Carlos Castaño; Núria DeGregorio-Rocasolano; Luis Rodríguez-Esparragoza; Antoni Dávalos; Octavi Martí-Sistac; Teresa Gasull
Journal:  Int J Mol Sci       Date:  2020-09-08       Impact factor: 5.923

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.