Literature DB >> 31247538

Wireless Resonant Circuits Printed Using Aerosol Jet Deposition for MRI Catheter Tracking.

Caroline D Jordan, Bradford R H Thorne, Arjun Wadhwa, Aaron D Losey, Eugene Ozhinsky, Sravani Kondapavulur, Vincent Fratello, Teri Moore, Carol Stillson, Colin Yee, Ronald D Watkins, Greig C Scott, Alastair J Martin, Xiaoliang Zhang, Mark W Wilson, Steven W Hetts.   

Abstract

Interventional magnetic resonance imaging (MRI) could allow for diagnosis and immediate treatment of ischemic stroke; however, such endovascular catheter-based procedures under MRI guidance are inherently difficult. One major challenge is tracking the tip of the catheter, as standard fabrication methods for building inductively coupled coil markers are rigid and bulky. Here, we report a new approach that uses aerosol jet deposition to three-dimensional (3-D) print an inductively coupled RF coil marker on a polymer catheter. Our approach enables lightweight conforming markers on polymer catheters and these low-profile markers allow the catheter to be more safely navigated in small caliber vessels. Prototype markers with an inductor with the geometry of a double helix are incorporated on catheters for in vitro studies, and we show that these markers exhibit good signal amplification. We report temperature measurements and, finally, demonstrate feasibility in a preliminary in vivo experiment. We provide material properties and electromagnetic simulation performance analysis. This paper presents fully aerosol jet-deposited and functional wireless resonant markers on polymer catheters for use in 3T clinical scanners.

Entities:  

Mesh:

Year:  2019        PMID: 31247538      PMCID: PMC6995687          DOI: 10.1109/TBME.2019.2922879

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  27 in total

1.  An optical system for wireless detuning of parallel resonant circuits.

Authors:  E Y Wong; Q Zhang; J L Duerk; J S Lewin; M Wendt
Journal:  J Magn Reson Imaging       Date:  2000-10       Impact factor: 4.813

2.  Pair of resonant fiducial markers for localization of endovascular catheters at all catheter orientations.

Authors:  Titus Kuehne; Rebecca Fahrig; Kim Butts
Journal:  J Magn Reson Imaging       Date:  2003-05       Impact factor: 4.813

3.  Interventional magnetic resonance angiography with no strings attached: wireless active catheter visualization.

Authors:  Harald H Quick; Michael O Zenge; Hilmar Kuehl; Gernot Kaiser; Stephanie Aker; Sandra Massing; Silke Bosk; Mark E Ladd
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

4.  A catheter tracking method using reverse polarization for MR-guided interventions.

Authors:  Haydar Celik; Asli Ulutürk; Turgut Tali; Ergin Atalar
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

5.  Tuned fiducial markers to identify body locations with minimal perturbation of tissue magnetization.

Authors:  M Burl; G A Coutts; I R Young
Journal:  Magn Reson Med       Date:  1996-09       Impact factor: 4.668

6.  Resonant marker design and fabrication techniques for device visualization during interventional magnetic resonance imaging.

Authors:  Mandy Kaiser; Markus Detert; Martin A Rube; Abubakr El-Tahir; Ole Jakob Elle; Andreas Melzer; Bertram Schmidt; Georg H Rose
Journal:  Biomed Tech (Berl)       Date:  2015-04       Impact factor: 1.411

7.  Thrombectomy for Stroke at 6 to 16 Hours with Selection by Perfusion Imaging.

Authors:  Gregory W Albers; Michael P Marks; Stephanie Kemp; Soren Christensen; Jenny P Tsai; Santiago Ortega-Gutierrez; Ryan A McTaggart; Michel T Torbey; May Kim-Tenser; Thabele Leslie-Mazwi; Amrou Sarraj; Scott E Kasner; Sameer A Ansari; Sharon D Yeatts; Scott Hamilton; Michael Mlynash; Jeremy J Heit; Greg Zaharchuk; Sun Kim; Janice Carrozzella; Yuko Y Palesch; Andrew M Demchuk; Roland Bammer; Philip W Lavori; Joseph P Broderick; Maarten G Lansberg
Journal:  N Engl J Med       Date:  2018-01-24       Impact factor: 91.245

8.  Interventional magnetic resonance imaging guided carotid embolectomy using a novel resonant marker catheter: demonstration of preclinical feasibility.

Authors:  Jeffrey K Yang; Andre M Cote; Caroline D Jordan; Sravani Kondapavulur; Aaron D Losey; David McCoy; Andrew Chu; Jay F Yu; Teri Moore; Carol Stillson; Fabio Settecase; Matthew D Alexander; Andrew Nicholson; Daniel L Cooke; Maythem Saeed; Dave Barry; Alastair J Martin; Mark W Wilson; Steven W Hetts
Journal:  Biomed Microdevices       Date:  2017-09-25       Impact factor: 2.838

9.  Modeling Endovascular MRI Coil Coupling With Transmit RF Excitation.

Authors:  Madhav Venkateswaran; Orhan Unal; Samuel Hurley; Alexey Samsonov; Peng Wang; Sean B Fain; Krishna N Kurpad
Journal:  IEEE Trans Biomed Eng       Date:  2016-03-04       Impact factor: 4.538

Review 10.  Imaging-guided acute ischemic stroke therapy: From "time is brain" to "physiology is brain".

Authors:  R G González
Journal:  AJNR Am J Neuroradiol       Date:  2006-04       Impact factor: 3.825

View more
  6 in total

1.  High-resolution intravascular magnetic resonance imaging of the coronary artery wall at 3.0 Tesla: toward evaluation of atherosclerotic plaque vulnerability.

Authors:  Yanfeng Meng; Zhiguang Mo; Jinying Hao; Yueyou Peng; Hui Yan; Jingbo Mu; Dengfeng Ma; Xiaoliang Zhang; Ye Li
Journal:  Quant Imaging Med Surg       Date:  2021-11

2.  A 20-gauge active needle design with thin-film printed circuitry for interventional MRI at 0.55T.

Authors:  Dursun Korel Yildirim; Christopher Bruce; Dogangun Uzun; Toby Rogers; Kendall O'Brien; Rajiv Ramasawmy; Adrienne Campbell-Washburn; Daniel A Herzka; Robert J Lederman; Ozgur Kocaturk
Journal:  Magn Reson Med       Date:  2021-04-16       Impact factor: 3.737

3.  Fabrication and Characterization of a Flexible Fluxgate Sensor with Pad-Printed Solenoid Coils.

Authors:  Spyridon Schoinas; Adyl-Michaël El Guamra; Fabien Moreillon; Philippe Passeraub
Journal:  Sensors (Basel)       Date:  2020-04-16       Impact factor: 3.576

4.  Wireless Reconfigurable RF Detector Array for Focal and Multiregional Signal Enhancement.

Authors:  Wei Qian; Xin Yu; Chunqi Qian
Journal:  IEEE Access       Date:  2020-07-24       Impact factor: 3.367

5.  Wireless Powered Encoding and Broadcasting of Frequency Modulated Detection Signals.

Authors:  Wei Qian; Xin Yu; Chunqi Qian
Journal:  IEEE Access       Date:  2020-11-04       Impact factor: 3.367

6.  Combined Use of X-ray Angiography and Intraprocedural MRI Enables Tissue-based Decision Making Regarding Revascularization during Acute Ischemic Stroke Intervention.

Authors:  Kazim H Narsinh; Bridget F Kilbride; Kerstin Mueller; Daniel Murph; Alexander Copelan; Jonathan Massachi; Jeffrey Vitt; Chung-Huan Sun; Himanshu Bhat; Matthew R Amans; Christopher F Dowd; Van V Halbach; Randall T Higashida; Terilyn Moore; Mark W Wilson; Daniel L Cooke; Steven W Hetts
Journal:  Radiology       Date:  2021-02-09       Impact factor: 11.105

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.