Filtered Backprojection Algorithm Can Outperform Iterative Maximum Likelihood Expectation-Maximization Algorithm.

Gengsheng L Zeng1.   

Abstract

The iterative maximum-likelihood expectation-maximization (ML-EM) algorithm is an excellent algorithm for image reconstruction and usually provides better images than the filtered backprojection (FBP) algorithm. However, a windowed FBP algorithm can outperform the ML-EM in certain occasions, when the least-squared difference from the true image, that is, the least-squared error (LSE), is used as the comparison criterion. Computer simulations were carried out for the two algorithms. For a given data set the best reconstruction (compared to the true image) from each algorithm was first obtained, and the two reconstructions are compared. The stopping iteration number of the ML-EM algorithm and the parameters of the windowed FBP algorithm were determined, so that they produced an image that was closest to the true image. However, to use the LSE criterion to compare algorithms, one must know the true image. How to select the optimal parameters when the true image is unknown is a practical open problem. For noisy Poisson projections, computer simulation results indicate that the ML-EM images are better than the regular FBP images, and the windowed FBP algorithm images are better than the ML-EM images. For the noiseless projections, the FBP algorithms outperform the ML-EM algorithm. The computer simulations reveal that the windowed FBP algorithm can provide a reconstruction that is closer to the true image than the ML-EM algorithm.

Entities:  

Keywords:  ML-EM algorithm; Poisson noise; filtered backprojection algorithm; image reconstruction

Year:  2012        PMID: 28931971      PMCID: PMC5602532          DOI: 10.1002/ima.22011

Source DB:  PubMed          Journal:  Int J Imaging Syst Technol        ISSN: 0899-9457            Impact factor:   2.000


  13 in total

1.  Comparison of parametric FBP and OS-EM reconstruction algorithm images for PET dynamic study.

Authors:  K Oda; H Toyama; K Uemura; Y Ikoma; Y Kimura; M Senda
Journal:  Ann Nucl Med       Date:  2001-10       Impact factor: 2.668

2.  A filtered backprojection MAP algorithm with nonuniform sampling and noise modeling.

Authors:  Gengsheng L Zeng
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

3.  A filtered backprojection algorithm with characteristics of the iterative landweber algorithm.

Authors:  Gengsheng L Zeng
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

4.  Precision and accuracy of regional radioactivity quantitation using the maximum likelihood EM reconstruction algorithm.

Authors:  R E Carson; Y Yan; B Chodkowski; T K Yap; M E Daube-Witherspoon
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

5.  Maximum likelihood reconstruction for emission tomography.

Authors:  L A Shepp; Y Vardi
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

6.  Performance evaluation of filtered backprojection reconstruction and iterative reconstruction methods for PET images.

Authors:  C X Wang; W E Snyder; G Bilbro; P Santago
Journal:  Comput Biol Med       Date:  1998-01       Impact factor: 4.589

7.  Effect of attenuation correction on myocardial thallium-201 distribution in patients with a low likelihood of coronary artery disease.

Authors:  E M Prvulovich; A H Lonn; J B Bomanji; P H Jarritt; P J Ell
Journal:  Eur J Nucl Med       Date:  1997-03

8.  Iterative algebraic reconstruction algorithms for emission computed tomography: a unified framework and its application to positron emission tomography.

Authors:  X L Xu; J S Liow; S C Strother
Journal:  Med Phys       Date:  1993 Nov-Dec       Impact factor: 4.071

9.  On the optimality of the filtered backprojection algorithm.

Authors:  K M Hanson
Journal:  J Comput Assist Tomogr       Date:  1980-06       Impact factor: 1.826

10.  Optimisation of the OS-EM algorithm and comparison with FBP for image reconstruction on a dual-head camera: a phantom and a clinical 18F-FDG study.

Authors:  Fabrice Gutman; Isabelle Gardin; Nicolas Delahaye; Hervé Rakotonirina; Anne Hitzel; Alain Manrique; Dominique Le Guludec; Pierre Véra
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-09-23       Impact factor: 9.236

View more
  1 in total

1.  Comparison of FBP and Iterative Algorithms with Non-Uniform Angular Sampling.

Authors:  Gengsheng L Zeng
Journal:  IEEE Trans Nucl Sci       Date:  2015-02       Impact factor: 1.679