Literature DB >> 28921448

Assessment of dose uniformity around high dose rate 192Ir and 60Co stepping sources.

Bagher Farhood1, Mahdi Ghorbani2.   

Abstract

This study aimed to evaluate dose uniformity for 192Ir and 60Co stepping sources. High dose rate 192Ir and 60Co stepping sources were simulated by the MCNPX Monte Carlo code. To investigate dose uniformity, treatment lengths of 30, 50, 100, and 150 mm with stepping distances of 3, 5, 7, and 10 mm were considered. Finally, dose uniformity for the 192Ir and 60Co stepping sources with increasing distances from the source were assessed at these treatment lengths and steps. The findings showed that the dose distribution was non-uniform for regions in close vicinity of the source, especially in the high source steps, but for most points at distances >10 mm from the center of the source, the dose distribution was uniform. For most points, the dose uniformity increased with reduction of the source steps and increments of the transverse distance from the source. The dose non-uniformity was similar for most of the corresponding points of 60Co and 192Ir sources with the same treatment lengths and source steps, except at the distance of 150 mm. When using stepping technique for the treatment of tumors, more attention should be focused on treatment planning, especially with higher stepping distances and lower transverse distances from the source.

Entities:  

Keywords:  Brachytherapy; Dose uniformity; Stepping source

Mesh:

Substances:

Year:  2017        PMID: 28921448     DOI: 10.1007/s12194-017-0418-1

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  27 in total

1.  Ir-192 HDR transit dose and radial dose function determination using alanine/EPR dosimetry.

Authors:  Carmen S Guzmán Calcina; Adelaide de Almeida; José R Oliveira Rocha; Felipe Chen Abrego; Oswaldo Baffa
Journal:  Phys Med Biol       Date:  2005-02-23       Impact factor: 3.609

2.  Tissue composition effect on dose distribution in neutron brachytherapy/neutron capture therapy.

Authors:  Mohsen Khosroabadi; Bagher Farhood; Mahdi Ghorbani; Nima Hamzian; Homa Rezaei Moghaddam; David Davenport
Journal:  Rep Pract Oncol Radiother       Date:  2015-06-10

3.  A Monte Carlo study on tissue dose enhancement in brachytherapy: a comparison between gadolinium and gold nanoparticles.

Authors:  Mohammad Taghi Bahreyni Toossi; Mahdi Ghorbani; Mohammad Mehrpouyan; Fateme Akbari; Leila Sobhkhiz Sabet; Ali Soleimani Meigooni
Journal:  Australas Phys Eng Sci Med       Date:  2012-06-15       Impact factor: 1.430

4.  Measurement and calculation of the dose at large distances from brachytherapy sources: Cs-137, Ir-192, and Co-60.

Authors:  J L Venselaar; P H van der Giessen; W J Dries
Journal:  Med Phys       Date:  1996-04       Impact factor: 4.071

5.  Dose enhancement by various nanoparticles in prostate brachytherapy.

Authors:  Mahdi Ghorbani; Mahdi Bakhshabadi; Alireza Golshan; Courtney Knaup
Journal:  Australas Phys Eng Sci Med       Date:  2013-12-04       Impact factor: 1.430

Review 6.  Intravascular brachytherapy for peripheral vascular disease.

Authors:  Alina Andras; Monica Hansrani; Marlene Stewart; Gerard Stansby
Journal:  Cochrane Database Syst Rev       Date:  2014-01-08

7.  Effect of tissue composition on dose distribution in brachytherapy with various photon emitting sources.

Authors:  Mahdi Ghorbani; Fateme Salahshour; Abbas Haghparast; Toktam Ahmadi Moghaddas; Courtney Knaup
Journal:  J Contemp Brachytherapy       Date:  2014-04-03

8.  A comparison study on various low energy sources in interstitial prostate brachytherapy.

Authors:  Mahdi Bakhshabadi; Mahdi Ghorbani; Mohsen Khosroabadi; Courtney Knaup; Ali S Meigooni
Journal:  J Contemp Brachytherapy       Date:  2016-02-05

9.  Dosimetric characterizations of GZP6 (60)Co high dose rate brachytherapy sources: application of superimposition method.

Authors:  Mohammad Taghi Bahreyni Toossi; Mahdi Ghorbani; Ali Asghar Mowlavi; Ali Soleimani Meigooni
Journal:  Radiol Oncol       Date:  2012-01-02       Impact factor: 2.991

10.  Evaluation of BEBIG HDR (60)Co system for non-invasive image-guided breast brachytherapy.

Authors:  Mehdi Zehtabian; Sedigheh Sina; Mark J Rivard; Ali S Meigooni
Journal:  J Contemp Brachytherapy       Date:  2015-12-30
View more
  1 in total

Review 1.  Comparative Analysis of 60Co and 192Ir Sources in High Dose Rate Brachytherapy for Cervical Cancer.

Authors:  Aiping Wen; Xianliang Wang; Bingjie Wang; Chuanjun Yan; Jingyue Luo; Pei Wang; Jie Li
Journal:  Cancers (Basel)       Date:  2022-09-29       Impact factor: 6.575

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.