Literature DB >> 9157267

Measurement and calculation of the dose at large distances from brachytherapy sources: Cs-137, Ir-192, and Co-60.

J L Venselaar1, P H van der Giessen, W J Dries.   

Abstract

In a small number of special cases it may be necessary to estimate the radiation dose to organs far away from the target volume of a patient receiving radiotherapy, e.g. the dose to the gonads or to the fetus of a pregnant patient. Previously, for external beam radiotherapy a model was developed, which enabled this estimation with acceptable accuracy for the range of photon beam energies from cobalt-60 to 25 MV, independent of the make of the treatment machines, for generally used techniques and for a wide range of distances from the beam axis and field sizes [Van der Giessen and Hurkmans, Int. J. Radiat. Oncol. Biol. Phys. 27, 717-724 (1993); van der Giessen, ibid. 30, 1239-1246 (1994); to appear in Int. J. Radiat. Oncol. Biol. Phys.]. In this paper, results of measurements and Monte Carlo calculations are reported for evaluation of the dose at large distances from some brachytherapy sources. This has resulted in information on the behavior of the tissue attenuation factor T(r) for commonly used sources: Co-60, Ir-192, and Cs-137, in the range of distances up to 60 cm from the source. The influence of the size of the phantom was investigated. A mathematical model, described earlier by Kornelsen and Young, proved to yield the best fit to the results [Br. J. Radiol. 54, 136 (1981)]. Parameters for this model are derived for these isotopes. A few experiments in a Rando Alderson phantom are presented to support the measurements and the calculations.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9157267     DOI: 10.1118/1.597811

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Dosimetric analysis of Co-60 source based high dose rate (HDR) brachytherapy: A case series of ten patients with carcinoma of the uterine cervix.

Authors:  Om Prakash Gurjar; Manika Batra; Priyusha Bagdare; Sandeep Kaushik; Atul Tyagi; Ayush Naik; Virendra Bhandari; Krishna Lal Gupta
Journal:  Rep Pract Oncol Radiother       Date:  2016-03-02

2.  Study of the dosimetric differences between (192)Ir and (60)Co sources of high dose rate brachytherapy for breast interstitial implant.

Authors:  Mourougan Sinnatamby; Vivekanandan Nagarajan; Reddy Kanipakam Sathyanarayana; Gunaseelan Karunanidhi; Vivekanandam Singhavajala
Journal:  Rep Pract Oncol Radiother       Date:  2016-05-11

3.  Assessment of dose uniformity around high dose rate 192Ir and 60Co stepping sources.

Authors:  Bagher Farhood; Mahdi Ghorbani
Journal:  Radiol Phys Technol       Date:  2017-09-18

4.  Comparative dosimetry of GammaMed Plus high-dose rate Ir brachytherapy source.

Authors:  N P Patel; B Majumdar; V Vijayan
Journal:  J Med Phys       Date:  2010-07

5.  Outcomes of patients with cervical cancer treated with low- or high-dose rate brachytherapy after concurrent chemoradiation.

Authors:  Aba Anoa Scott; Joel Yarney; Verna Vanderpuye; Charles Akoto Aidoo; Mervin Agyeman; Samuel Ntiamoah Boateng; Evans Sasu; Kwabena Anarfi; Tony Obeng-Mensah
Journal:  Int J Gynecol Cancer       Date:  2021-02-08       Impact factor: 3.437

6.  Monte Carlo investigation of energy response of various detector materials in ¹²⁵I and ¹⁶⁹Yb brachytherapy dosimetry.

Authors:  T Palani Selvam; Biju Keshavkumar
Journal:  J Appl Clin Med Phys       Date:  2010-07-28       Impact factor: 2.102

7.  Treatment planning study of the 3D dosimetric differences between Co-60 and Ir-192 sources in high dose rate (HDR) brachytherapy for cervix cancer.

Authors:  Antony Palmer; Orla Hayman; Sarah Muscat
Journal:  J Contemp Brachytherapy       Date:  2012-03-30

8.  Comparison of (60)Co and (192)Ir sources in HDR brachytherapy.

Authors:  Stefan Strohmaier; Grzegorz Zwierzchowski
Journal:  J Contemp Brachytherapy       Date:  2011-12-30

9.  High-Dose-Rate (192)Ir Brachytherapy Dose Verification: A Phantom Study.

Authors:  Alireza Nikoofar; Zohreh Hoseinpour; Seied Rabi Mahdavi; Hadi Hasanzadeh; Mostafa Rezaei Tavirani
Journal:  Iran J Cancer Prev       Date:  2015-05-22

10.  Treatment outcomes of high-dose-rate intracavitary brachytherapy for cervical cancer: a comparison of Ir-192 versus Co-60 sources.

Authors:  Thanatip Tantivatana; Kanisa Rongsriyam
Journal:  J Gynecol Oncol       Date:  2018-09       Impact factor: 4.401