Ir-192 HDR transit dose and radial dose function determination using alanine/EPR dosimetry.

Carmen S Guzmán Calcina1, Adelaide de Almeida, José R Oliveira Rocha, Felipe Chen Abrego, Oswaldo Baffa.   

Abstract

Source positioning close to the tumour in high dose rate (HDR) brachytherapy is not instantaneous. An increment of dose will be delivered during the movement of the source in the trajectory to its static position. This increment is the transit dose, often not taken into account in brachytherapeutic treatment planning. The transit dose depends on the prescribed dose, number of treatment fractions, velocity and activity of the source. Combining all these factors, the transit dose can be 5% higher than the prescribed absorbed dose value (Sang-Hyun and Muller-Runkel, 1994 Phys. Med. Biol. 39 1181-8, Nath et al 1995 Med. Phys. 22 209-34). However, it cannot exceed this percentage (Nath et al 1995). In this work, we use the alanine-EPR (electron paramagnetic resonance) dosimetric system using analysis of the first derivative of the signal. The transit dose was evaluated for an HDR system and is consistent with that already presented for TLD dosimeters (Bastin et al 1993 Int. J. Radiat. Oncol. Biol. Phys. 26 695-702). Also using the same dosimetric system, the radial dose function, used to evaluate the geometric dose degradation around the source, was determined and its behaviour agrees better with those obtained by Monte Carlo simulations (Nath et al 1995, Williamson and Nath 1991 Med. Phys. 18 434-48, Ballester et al 1997 Med. Phys. 24 1221-8, Ballester et al 2001 Phys. Med. Biol. 46 N79-90) than with TLD measurements (Nath et al 1990 Med. Phys. 17 1032-40).

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15798311     DOI: 10.1088/0031-9155/50/6/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Assessment of dose uniformity around high dose rate 192Ir and 60Co stepping sources.

Authors:  Bagher Farhood; Mahdi Ghorbani
Journal:  Radiol Phys Technol       Date:  2017-09-18

Review 2.  Clinical applications of alanine/electron spin resonance dosimetry.

Authors:  Oswaldo Baffa; Angela Kinoshita
Journal:  Radiat Environ Biophys       Date:  2014-01-08       Impact factor: 1.925

3.  Impact of source position on high-dose-rate skin surface applicator dosimetry.

Authors:  Jeho Jeong; Christopher A Barker; Marco Zaider; Gil'ad N Cohen
Journal:  Brachytherapy       Date:  2016-06-01       Impact factor: 2.362

4.  Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques.

Authors:  Antony Palmer; David Bradley; Andrew Nisbet
Journal:  J Contemp Brachytherapy       Date:  2012-06-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.