Epidural anesthesia affects pulse oximeter readings and response time.

Shin Kawana1, Hiroaki Watanabe1, Akiyoshi Namiki1, Naohiro Kokita1.   

Abstract

We investigated the effects of epidural anesthesia on pulse oximeter readings (Spo2) and response time because this type of anesthesia causes significant changes in microcirculation at measurement sites. Twenty patients were divided into lumbar epidural (L-EPI;n=10) and the cervical epidural (C-EPI;n=10) groups. Spo2 and skin blood flow (SBF) were measured at the finger and toe simultaneously by pulse oximeter and laser Doppler flowmeter, respectively. Data were collected before and after epidural anesthesia for 1 min and the response time was calculated by the difference between the finger and toe using the breath-holding method. Epidural anesthesia increased SBF in the blocked area and decreased it in the nonblocked area in both groups (P<0.01, respectively). In the L-EPI group, Spo2 was increased at the finger (P<0.05) and decreased at the toe (P<0.05). In the C-EPI group, Spo2 at both the finger and toe was decreased by the anesthesia. ΔSpo2 (Spo2 at the finger minus Spo2 at the toe) was increased in the L-EPI group (P<0.05) and decreased in the C-EPI group (P<0.01). The difference in the response time became larger in the C-EPI group and smaller or opposite in the L-EPI group after anesthesia. The difference in response time and SBF were significantly correlated (r=0.71;P<0.05). These results indicated that epidural anesthesia lowerd Spo2 and shortened the response time through vasodilation in the blocked area and caused the opposite reactions in the nonblocked area through compensatory vasoconstriction.

Entities:  

Keywords:  epidural anesthesia; pulse oximeter; skin blood flow

Year:  1994        PMID: 28921136     DOI: 10.1007/BF02514705

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  10 in total

Review 1.  Potential errors in pulse oximetry. I. Pulse oximeter evaluation.

Authors:  A C Ralston; R K Webb; W B Runciman
Journal:  Anaesthesia       Date:  1991-03       Impact factor: 6.955

Review 2.  Principles of pulse oximetry: theoretical and practical considerations.

Authors:  C M Alexander; L E Teller; J B Gross
Journal:  Anesth Analg       Date:  1989-03       Impact factor: 5.108

3.  Effects of intravenously administered dyes on pulse oximetry readings.

Authors:  M S Scheller; R J Unger; M J Kelner
Journal:  Anesthesiology       Date:  1986-11       Impact factor: 7.892

4.  Pulse oximetry and circulatory kinetics associated with pulse volume amplitude measured by photoelectric plethysmography.

Authors:  J M Kim; K Arakawa; K T Benson; D K Fox
Journal:  Anesth Analg       Date:  1986-12       Impact factor: 5.108

5.  Blood flow limits and pulse oximeter signal detection.

Authors:  D Lawson; I Norley; G Korbon; R Loeb; J Ellis
Journal:  Anesthesiology       Date:  1987-10       Impact factor: 7.892

6.  Blood flow limits and signal detection comparing five different models of pulse oximeters.

Authors:  G B Greenblott; S Gerschultz; K K Tremper
Journal:  Anesthesiology       Date:  1989-02       Impact factor: 7.892

Review 7.  Potential errors in pulse oximetry. II. Effects of changes in saturation and signal quality.

Authors:  R K Webb; A C Ralston; W B Runciman
Journal:  Anaesthesia       Date:  1991-03       Impact factor: 6.955

8.  Accuracy of response of six pulse oximeters to profound hypoxia.

Authors:  J W Severinghaus; K H Naifeh
Journal:  Anesthesiology       Date:  1987-10       Impact factor: 7.892

9.  Evaluation of the Ohmeda 3700 pulse oximeter: steady-state and transient response characteristics.

Authors:  D M Kagle; C M Alexander; R S Berko; M Giuffre; J B Gross
Journal:  Anesthesiology       Date:  1987-03       Impact factor: 7.892

10.  The effect of sympathetic innervation on canine muscle and skin blood flow.

Authors:  J L Cronenwett; G B Zelenock; W M Whitehouse; J C Stanley; S M Lindenauer
Journal:  Arch Surg       Date:  1983-04
  10 in total