Literature DB >> 28910761

Phantomless Auto-Calibration and Online Calibration Assessment for a Tracked Freehand 2-D Ultrasound Probe.

Matthew Toews, William M Wells.   

Abstract

This paper presents a method for automatically calibrating and assessing the calibration quality of an externally tracked 2-D ultrasound (US) probe by scanning arbitrary, natural tissues, as opposed a specialized calibration phantom as is the typical practice. A generative topic model quantifies the posterior probability of calibration parameters conditioned on local 2-D image features arising from a generic underlying substrate. Auto-calibration is achieved by identifying the maximum a-posteriori image-to-probe transform, and calibration quality is assessed online in terms of the posterior probability of the current image-to-probe transform. Both are closely linked to the 3-D point reconstruction error (PRE) in aligning feature observations arising from the same underlying physical structure in different US images. The method is of practical importance in that it operates simply by scanning arbitrary textured echogenic structures, e.g., in-vivo tissues in the context of the US-guided procedures, without requiring specialized calibration procedures or equipment. Observed data take the form of local scale-invariant features that can be extracted and fit to the model in near real-time. Experiments demonstrate the method on a public data set of in vivo human brain scans of 14 unique subjects acquired in the context of neurosurgery. Online calibration assessment can be performed at approximately 3 Hz for the US images of pixels. Auto-calibration achieves an internal mean PRE of 1.2 mm and a discrepancy of [2 mm, 6 mm] in comparison to the calibration via a standard phantom-based method.

Entities:  

Mesh:

Year:  2017        PMID: 28910761      PMCID: PMC5808952          DOI: 10.1109/TMI.2017.2750978

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  21 in total

1.  Beam calibration without a phantom for creating a 3-D freehand ultrasound system.

Authors:  D M Muratore; R L Galloway
Journal:  Ultrasound Med Biol       Date:  2001-11       Impact factor: 2.998

Review 2.  Three-dimensional ultrasound imaging.

Authors:  R W Prager; U Z Ijaz; A H Gee; G M Treece
Journal:  Proc Inst Mech Eng H       Date:  2010       Impact factor: 1.617

3.  Learning to estimate out-of-plane motion in ultrasound imagery of real tissue.

Authors:  Catherine Laporte; Tal Arbel
Journal:  Med Image Anal       Date:  2010-09-18       Impact factor: 8.545

Review 4.  A review of calibration techniques for freehand 3-D ultrasound systems.

Authors:  Laurence Mercier; Thomas Langø; Frank Lindseth; D Louis Collins
Journal:  Ultrasound Med Biol       Date:  2005-04       Impact factor: 2.998

5.  A novel phantom-less spatial and temporal ultrasound calibration method.

Authors:  Ali Khamene; Frank Sauer
Journal:  Med Image Comput Comput Assist Interv       Date:  2005

6.  Real-time quality control of tracked ultrasound.

Authors:  Emad M Boctor; Iulian Iordachita; Gabor Fichtinger; Gregory D Hager
Journal:  Med Image Comput Comput Assist Interv       Date:  2005

7.  Sensorless reconstruction of unconstrained freehand 3D ultrasound data.

Authors:  R James Housden; Andrew H Gee; Graham M Treece; Richard W Prager
Journal:  Ultrasound Med Biol       Date:  2007-03       Impact factor: 2.998

8.  Rapid calibration for 3-D freehand ultrasound.

Authors:  R W Prager; R N Rohling; A H Gee; L Berman
Journal:  Ultrasound Med Biol       Date:  1998-07       Impact factor: 2.998

9.  A closed-form differential formulation for ultrasound spatial calibration: multi-wedge phantom.

Authors:  Mohammad Najafi; Narges Afsham; Purang Abolmaesumi; Robert Rohling
Journal:  Ultrasound Med Biol       Date:  2014-06-07       Impact factor: 2.998

10.  Online database of clinical MR and ultrasound images of brain tumors.

Authors:  Laurence Mercier; Rolando F Del Maestro; Kevin Petrecca; David Araujo; Claire Haegelen; D Louis Collins
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

View more
  4 in total

1.  Verification of Guiding Needle Placement by Registered Ultrasound Image During Combined Intracavitary/Interstitial Gynecologic Brachytherapy.

Authors:  Jing Zeng; Ziqi Liu; Shan Jiang; Qingsong Pang; Ping Wang
Journal:  Cancer Manag Res       Date:  2021-02-24       Impact factor: 3.989

2.  Integrated multi-modality image-guided navigation for neurosurgery: open-source software platform using state-of-the-art clinical hardware.

Authors:  Jonathan Shapey; Thomas Dowrick; Rémi Delaunay; Eleanor C Mackle; Stephen Thompson; Mirek Janatka; Roland Guichard; Anastasis Georgoulas; David Pérez-Suárez; Robert Bradford; Shakeel R Saeed; Sébastien Ourselin; Matthew J Clarkson; Tom Vercauteren
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-05-03       Impact factor: 3.421

3.  The Essential Role of Open Data and Software for the Future of Ultrasound-Based Neuronavigation.

Authors:  Ingerid Reinertsen; D Louis Collins; Simon Drouin
Journal:  Front Oncol       Date:  2021-02-02       Impact factor: 6.244

4.  Verification of needle guidance accuracy in pelvic phantom using registered ultrasound and MRI images for intracavitary/interstitial gynecologic brachytherapy.

Authors:  Zhiyong Yang; Ziqi Liu; Shan Jiang; Jing Zeng; Yuanjing Hu; Guobin Zhang
Journal:  J Contemp Brachytherapy       Date:  2020-04-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.