Literature DB >> 17280771

Sensorless reconstruction of unconstrained freehand 3D ultrasound data.

R James Housden1, Andrew H Gee, Graham M Treece, Richard W Prager.   

Abstract

Freehand 3D ultrasound can be acquired without a position sensor by finding the separations of pairs of frames using information in the images themselves. Previous work has not considered how to reconstruct entirely freehand data, which can exhibit irregularly spaced frames, intersecting frames, nonmonotonic out-of-plane probe motion and significant in-plane motion. This paper presents reconstruction methods that overcome these limitations and are able to robustly reconstruct unconstrained freehand data. The methods are assessed on freehand data sets and compared with reconstructions obtained with a position sensor.

Mesh:

Year:  2007        PMID: 17280771     DOI: 10.1016/j.ultrasmedbio.2006.09.015

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  7 in total

1.  Phantomless Auto-Calibration and Online Calibration Assessment for a Tracked Freehand 2-D Ultrasound Probe.

Authors:  Matthew Toews; William M Wells
Journal:  IEEE Trans Med Imaging       Date:  2017-09-11       Impact factor: 10.048

2.  Using game controller as position tracking sensor for 3D freehand ultrasound imaging.

Authors:  Vei Siang Chan; Farhan Mohamed; Yusman Azimi Yusoff; Dyah Ekashanti Octorina Dewi; Alfiera Anuar; Mohamad Amir Shamsudin; Wey Sheng Mong
Journal:  Med Biol Eng Comput       Date:  2019-10-10       Impact factor: 2.602

3.  PLUS: open-source toolkit for ultrasound-guided intervention systems.

Authors:  Andras Lasso; Tamas Heffter; Adam Rankin; Csaba Pinter; Tamas Ungi; Gabor Fichtinger
Journal:  IEEE Trans Biomed Eng       Date:  2014-05-09       Impact factor: 4.538

4.  Calibration of an orientation sensor for freehand 3D ultrasound and its use in a hybrid acquisition system.

Authors:  Richard James Housden; Graham M Treece; Andrew H Gee; Richard W Prager
Journal:  Biomed Eng Online       Date:  2008-01-24       Impact factor: 2.819

5.  Measurement of Flow Volume in the Presence of Reverse Flow with Ultrasound Speckle Decorrelation.

Authors:  Xiaowei Zhou; Xinhuan Zhou; Chee Hau Leow; Meng-Xing Tang
Journal:  Ultrasound Med Biol       Date:  2019-08-01       Impact factor: 2.998

6.  3D-XGuide: open-source X-ray navigation guidance system.

Authors:  Ina Vernikouskaya; Dagmar Bertsche; Wolfgang Rottbauer; Volker Rasche
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-10-15       Impact factor: 2.924

7.  Fast Acoustic Steering Via Tilting Electromechanical Reflectors (FASTER): A Novel Method for High Volume Rate 3-D Ultrasound Imaging.

Authors:  Zhijie Dong; Shuangliang Li; Matthew R Lowerison; Jason Pan; Jun Zou; Pengfei Song
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.